期刊文献+

某电厂水冷壁爆管原因分析及建议 被引量:4

Cause Analysis and Suggestion of Water Wall Tube Explosion in a Power Plant
在线阅读 下载PDF
导出
摘要 为了解水冷壁爆管原因,采用宏观形貌分析、金相分析、硬度测量、力学性能试验,对取样管进行了分析,结果表明本次爆管是超温温度低于材料Ac1(727℃)的短时超温爆管,超温与管子内介质流量不足有密切关系。 In order to understand the causes of water-cooled wall tube bursts,the macro morphology analysis,metallographic analysis,hardness measurement,and mechanical performance tests were used to analyze the sampling tubes.The results showed that the explosion was a short-time over temperature explosion with the over temperature lower than AC1(727℃),which was closely related to the insufficient medium flow rate in the tube.
作者 李鹏刚 LI Penggang(Huadian Electric Power Research Institute Co.,Ltd.,Hangzhou 310030,China)
出处 《电工技术》 2020年第9期155-156,158,共3页 Electric Engineering
关键词 水冷壁 爆管 Ac1 短时超温 water wall tube burst AC1 short-time over temperature