基于TCP/IP协议的小动物PET数据传输系统的设计与实现 被引量:1

Design and Implementation of Data Transmission System for Small-animal PET Based on TCP/IP Protocol
在线阅读 下载PDF
导出
摘要 为了实现小动物PET系统数据高速传输的可靠性,采用TCP/IP协议对数据进行传输模拟。通过分析客户端/服务器模式控制数据的发送与接收,优化了客户端的处理能力,响应时间快;降低了系统的通讯开销,提高数据传输的安全性与可靠性。 To enhance the graphy(PET) system, TCP/IP and transmitting by the Client/ sponse time is fast. of data transmission. reliability of high-speed data transmission for small animal Positron Emission Tomo- protocol is adopt to simulate high-speed data transmit, maken the data connection Server communication mechanism, optimize the processing capacity of client. Re- nication overhead of the system is reducd, and improved the security and reliability
出处 《科学技术与工程》 北大核心 2013年第1期23-27,共5页 Science Technology and Engineering
关键词 TCP IP PET 数据传输 客户端 服务器端 TCP/IP PET data transmission client server
  • 相关文献

参考文献15

  • 1Pekhteryev G,Sahinoglu Z,Orlik P. Image transmission over IEEE 802.15.4 and ZigBee networks[R].2005.
  • 2朱俊,张博,张智,谢庆国.便携式PET数据无线传输的可行性探讨[J].CT理论与应用研究(中英文),2007,16(3):50-59. 被引量:2
  • 3王艳萍.小型动物正电子发射断层扫描仪数据采集系统的研制[M]武汉:华中科技大学,20064.
  • 4陈亚微.小型PET样机符合系统的设计与实现[M]武汉:华中科技大学,20064.
  • 5Kim S. Offloading socket processing for ubiqui-tous services[J].Journal of Information Science and Engineering,2011,(01):19-33.
  • 6Stevens W R;范建华.TCP/IP详解,卷1:协议[M]北京:机械工业出版社,20004.
  • 7臧桂鹏;肖佳放;顾松东.Visual C++网络与数据库编程百例[M]北京:中国电力出版社,2003.
  • 8王燕芳,刘力,魏龙,单保慈.小动物正电子断层扫描仪(Micro-PET)技术概述[J].中国体视学与图像分析,2005,10(3):174-176. 被引量:9
  • 9孙广彬.PET系统中数据采集模式的实现[M]郑州:郑州大学,2003.
  • 10Cutler PD,Cherry SR,Hoffman E J. Design features and performance of a PET system for animal research[J].The Journal of Nuclear Medicine,1992,(04):595-604.

二级参考文献18

  • 1[1]C Nichol,E E Kim.Molecular imaging and gene therapy[J].Nucl Med,2001,42:1368-1373.
  • 2[2]G D Luker,D Piwnica-Worms.Beyond the genome:Molecular imaging in vivo with PET and SPECT[J].Acad Radiol,2001,8:4-14.
  • 3[3]Y-C Tai AF Chatziioannou RW Silverman K Meadors.MicroPET II:an ultra-high resolution small animal PET system[C].Conference Record of the 2003 IEEE Nuclear Science Symposium and Medical Imaging Conference,2003:1848-1952.
  • 4[4]M E Phelps.PET:The merging of biology and imaging into molecular imaging[J].Nucl Med,2000,41:661-681.
  • 5[5]Qingguo Xie,Chien-Min Kao,Rongsheng Xia,et al.A Simple All-digital PET System[C].Proc of SPIE,2007,6510:41-97.
  • 6[6]IEEE Std 802.11b-1999(Supplement to ANSI/IEEE Std 802.11,1999 Edition)[S].
  • 7[7]IEEE Std 802.11a-1999(Supplement to IEEE Std 802.11-1999)[S].
  • 8[8]IEEE Std 802.11g(TM)-2003 (Amendment to IEEE Std 802.11(TM),1999 Edition (Reaff 2003)as amended by IEEE Stds 802.11a(TM)-1999,802.11b(TM)-1999,802.11b(TM)-1999/Cor 1-2001,and 802.11d(TM)-2001)[S].
  • 9[9]M K Abdul Aziz,A R Nix,P N Fletcher.A Study of Performance and Complexity for IEEE 802.11n MIMO-OFDM GIS Solutions[C].Communications 2004 IEEE International Conference on,2006,7:3822-3826.
  • 10[10]Ishiyama Y,Ohtsuki T.Performance evaluation of UWB-IR and DS-UWB with MMSE-frequency domain equalization (FDE)[C],Global Telecommunications Conference,2004 GLOBECOM'04,IEEE.2004,5:3093-3097.

共引文献9

同被引文献10

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部