摘要
锅炉水冷壁管、过热器管、再热器管、省煤器管"四管"爆漏是火力发电厂的常见故障,锅炉"四管"爆漏的预防是一项长期而复杂的工作。介绍广州珠江电厂锅炉"四管"爆漏情况,分析了"四管"爆漏原因。该厂采取相应的预防措施后,取得了显著的效果,其方法可供同行参考。
The prevention of four tubes leakage is a long-term and complicated work in thermal power plant.The four tubes leakage in Zhujiang power plant boiler is introduced,and the reasons are analyzed.Obvious effect has been obtained after taking related preventive measures.
出处
《陕西电力》
2011年第4期78-81,共4页
Shanxi Electric Power
关键词
燃煤锅炉
水冷壁管
过热器管
再热器管
省煤器管
“四管”爆漏
coal-fired boilers
water wall tube
superheater tube
reheater tube
economizer tube
four tubes leakage