期刊文献+

1100t/h直流锅炉过热器、再热器材质状态试验研究 被引量:2

Test and Research on the Material State of Superheater and Reheater in 1100t/h DC Boiler
在线阅读 下载PDF
导出
摘要 通过化学成分分析、高温室温拉伸试验、显微组织分析、微区扫描电镜及能谱分析、钢管内外壁氧化腐蚀分析等方法,对1 100 t/h直流锅炉运行5万h以上其过热器和再热器钢管寿命状态进行试验研究。通过对试验数据、向火面与背火面显微组织、脱碳层及高温氧化腐蚀的综合分析,确认过热器Ⅰ材质老化及氧化腐蚀程度严重,要求在适当时间安排更换;再热器Ⅰ材质中度老化,应加强对该钢管的金属监督检查。 By means of chemical composition analysis, tensile test in high and normal temperature, microscopic constitution, scanning electro-microscopy and energy spectrum analysis, oxidated corrosion analysis on inner and outer pipe wall, the life state of the steel pipe in superheater and reheater with operation for more than 50,000h in 1 100t/h DC boiler is tested. Comprehensive analysis of the test data, microscopic constitution of fireside and fire-resistant side surface, decarburized layer and high temperature oxidated corro- sion confirms the superheater I has the severe troubles of material aging and oxidated corrosion. The superheater I should be changed in an appropriate time. The reheater I with moderated aging should be monitored for metal supervision and examination with more attention.
出处 《陕西电力》 2007年第1期27-31,共5页 Shanxi Electric Power
关键词 锅炉 受热面 过热器 再热器 氧化腐蚀 boiler heated surface superheater reheater oxidated corrosion
  • 相关文献

参考文献2

二级参考文献3

共引文献26

同被引文献4

  • 1黄伟,李文军,何曙光,赵红宇,钟建明,孔鹏程.600MW超临界机组采用稳压和降压相结合的吹管工艺分析[J].电力设备,2007,8(4):28-32. 被引量:6
  • 2DL/T 787-2001.火电厂用15CrMo钢珠光体球化评级标准[S].,.
  • 3董重里,郑志军.锅炉包墙过热器拉稀管失效分析[A].年全国失效分析学术会议论文集.2011
  • 4史志刚,马红,唐丽英,李益民.电站锅炉水冷壁管腐蚀疲劳断口分析[A].年全国失效分析学术会议论文集.2007

引证文献2