摘要
细水雾灭火系统是一种新型先进的自动灭火系统,具有安全性高、节约投资及环保等特点。对细水雾灭火系统在地铁车站的应用进行技术经济分析,认为将该系统应用于地铁车站工程中,不仅能够取得较为理想的灭火效果,同时还能够取得可观的经济、环境及社会效益。对细水雾灭火系统应用于地铁车站进行系统选型设计,推荐采用高压泵组式细水雾灭火系统,并对该系统在地铁车站中的应用提出建议。
Water mist fire-extinguishing system is an investment-saving and environmentally friendly new system of great security based on advanced technology. The paper analyzes the application of this system in metro stations and concludes that it is efficient in fire extinguishing in terms of economic and environnmental advantages. Problems in the design of water mist fire-extinguishers are discussed and some suggestions for the application of high pressure water mist fire-extinguishing system in metro stations are presented.
出处
《都市快轨交通》
2008年第2期86-89,共4页
Urban Rapid Rail Transit
关键词
细水雾灭火系统
地铁车站
应用分析
water mist fire-extinguishing system
metro station
analysis of application