期刊文献+

通风条件下细水雾灭火的临界水流率 被引量:5

Critical Flow Rate of Water Mist Fire Extinguishment Under Ventilation
在线阅读 下载PDF
导出
摘要 临界水流率是细水雾系统的重要设计参数.为了研究通风条件对细水雾灭火临界水流率的影响,开展了一系列细水雾熄灭木垛火的模拟实验.实验结果表明,对于木垛火,细水雾的临界水流率同时受到热释放速率、有效喷嘴直径、高度、风速和雾化锥角的影响.基于Heskestad的临界水流率预测模型,利用量纲分析得到的指数关系式对实验数据进行拟合,对纳入通风风速后的模型各参数指数进行了修正,从而将其拓展至通风条件下. Critical flow rate, one of the important design parameters of water mist system, is likely to be affected by ventilation. To study the influence laws, simulative experiments of wood crib fire extinguishment by water mist were performed. The experimental results showed that critical flow rate of water mist was affected by heat release rate, effective nozzle diameter, height, wind velocity and spray angle. Based on the prediction model of critical flow rate presented by Heskestad, the experimental data were fitted by exponential equations. The parameter exponents were modified for the model, in which wind velocity was taken into account, and the prediction model was then extended for ventilation conditions.
作者 朱伟 陈吕义
出处 《燃烧科学与技术》 EI CAS CSCD 北大核心 2008年第5期412-416,共5页 Journal of Combustion Science and Technology
基金 北京市科技新星计划资助项目(2007-B-041)
关键词 灭火 细水雾 通风 水流率 fire extinguishment water mist ventilation flow rate
  • 相关文献

参考文献11

  • 1Liu Z G, Kim A K. A review of water mist suppression technology : Fundamental studies [ J]. Journal of Fire Protection Engineering, 2000, 10(3) : 32-50.
  • 2Yao B, Chow W K. A review of water mist fire suppression systems[ J]. Journal of Applied Fire Science, 2001, 10( 3 ) : 277 -294.
  • 3Liu Z G, Kim A K, Su J Z. A review of water mist suppression technology ( Part II) : A application studies [ J ]. Journal of Fire Protection Engineering, 2001, 11 (1) : 164-193.
  • 4Heskestad G. Scaling the interaction of water sprays and flames[J]. Fire Safety Journal, 2002, 37(6): 535-548.
  • 5Yao B, Fan W C, Liao G X. Interaction of water mists with a diffusion flame in a confined space [ J ]. Fire Safety Journal, 1999, 33(2): 129-139.
  • 6Wang X S, Liao G X, Qin J, et al. Experimental study on the effectiveness of the extinction of a pool fire with water mist [ J ]. Journal of Fire Science, 2002, 20 (4): 279-296.
  • 7Stahl P. A thermodynamic examination of the extinguishing properties of water spray and water mist [ C ]///6th Asia-Oceania Symposium on Fire Science and Technology. Daegu, Korea, 2004: 1038-1053.
  • 8Heskestad G. Extinction of gas and liquid pool fires with water sprays [ J]. Fire Safety Journal, 2003, 38 (4) : 301-317.
  • 9王旭红,刘学志.细水雾灭火系统在地铁中的应用[J].铁路工程造价管理,2006,21(5):36-38. 被引量:7
  • 10Yuan L M, Lazzara C P. The effects of ventilation and preburn time on water mist extinguishing of diesel fuel pool fires [J]. Journal of Fire Science, 2004, 22(5) : 379-404.

二级参考文献12

  • 1胡隆华,霍然,王浩波,李元洲,陆潜,杨立中.用CO浓度判别木垛燃烧从通风控制转为燃料控制的临界状态[J].燃烧科学与技术,2004,10(4):371-374. 被引量:2
  • 2Carvel RO,BeardAN,JowittPW,etal.The influence of tunnel geometry and ventilation on the heat release rate of a fire[J].Fire Technology,2004,40 (1):5-26.
  • 3Beard A N.Major fire spread in a tunnel:A non-linear model[C]// Proc 4th Int Conf on Safety in Road and Rail Tunnels.Madrid,Spain,2001:467-476.
  • 4Chow W K.On smoke control for tunnels by longitudinal ventilation [J].Tunnelling and Underground Space Technology,1998,13(3):271-275.
  • 5Wu Y,Baker M Z A.Control of smoke flow in tunnel fires using longitudinal ventilation systems-a study of the critical velocity [J].Fire Safety Journal,2000,35 (4):363 -390.
  • 6Gross D.Experiments on the burning of cross piles of wood [J].Journal of Research of the National Bureau of Standards (Engineering and Instrumentation),1962,66C (2):99-105.
  • 7Delichatsios M A.Fire growth rates in wood cribs[J].Combustion and Flame,1976,27 (3):267-278.
  • 8Heskestad G.Physical modeling of fire[J].Journal of Fire and Flammability,1975,6(3):253-273.
  • 9Quintiere J G.Scaling applications in fire research[J].Fire Safety Journal,1989,15 (1):1-12.
  • 10傅维标 张永廉 王清安.燃烧学[M].北京:高等教育出版社,1989..