期刊文献+

A Combined Forward Osmosis and Membrane Distillation System for Sidestream Treatment 被引量:2

A Combined Forward Osmosis and Membrane Distillation System for Sidestream Treatment
在线阅读 下载PDF
导出
摘要 Separate treatment of high-nutrient sidestream is an efficient and cost effective way to decrease the loading on the main plant, resulting in lower effluent nutrient concentration. This study investigated the use of a combined forward osmosis-membrane distillation (FO-MD) system for the removal of nitrogen present in high concentration in sidestream from anaerobic digestion process. The combined system was able to achieve almost 100% rejection of solids and acetic acid, and more than 98% rejection of NH3-N from the sidestream. The high rejection of NH3-N was mainly achieved by the FO process. The solids in the feed solution contributed to fouling problem in both FO and MD, resulting in significant decline in flux. However, 76% or higher flux recovery was achieved for FO membrane by cleaning with tap water. We observed that flux recovery was due to removal of solids from the membrane surface by the cleaning process. FO membrane also demonstrated excellent performance for continuous operation when cleaned for 15 min in every 24 h interval. Overall, the combined FO-MD system was found to be an effective solution for treatment of nutrient rich sidestream. Separate treatment of high-nutrient sidestream is an efficient and cost effective way to decrease the loading on the main plant, resulting in lower effluent nutrient concentration. This study investigated the use of a combined forward osmosis-membrane distillation (FO-MD) system for the removal of nitrogen present in high concentration in sidestream from anaerobic digestion process. The combined system was able to achieve almost 100% rejection of solids and acetic acid, and more than 98% rejection of NH3-N from the sidestream. The high rejection of NH3-N was mainly achieved by the FO process. The solids in the feed solution contributed to fouling problem in both FO and MD, resulting in significant decline in flux. However, 76% or higher flux recovery was achieved for FO membrane by cleaning with tap water. We observed that flux recovery was due to removal of solids from the membrane surface by the cleaning process. FO membrane also demonstrated excellent performance for continuous operation when cleaned for 15 min in every 24 h interval. Overall, the combined FO-MD system was found to be an effective solution for treatment of nutrient rich sidestream.
出处 《Journal of Water Resource and Protection》 2015年第14期1111-1120,共10页 水资源与保护(英文)
关键词 FORWARD Osmosis MEMBRANE DISTILLATION Sidestream TREATMENT NUTRIENT REMOVAL Forward Osmosis Membrane Distillation Sidestream Treatment Nutrient Removal
  • 相关文献

同被引文献11

引证文献2

二级引证文献39

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部