期刊文献+

放散塔熄火原因分析与改造实践 被引量:4

Cause Analysis and Transformation Practice of Flameout of Blowdown Tower
在线阅读 下载PDF
导出
摘要 国内钢铁企业不少放散塔采用高炉煤气直燃技术,不仅可以避免直接对空放散产生的环境污染问题,还可以减少高品质煤气损耗。结合唐钢新区高炉煤气直燃放散塔熄火案例,探究了放散塔的熄火原因,明确整改措施,为同行提供参考。 Blast furnace gas direct combustion technology has been adopted in many re lease towers of domestic steel enterprises,which can not only avoid the environmental pollu tion caused by direct air release,but also reduce the loss of high-quality gas.Combining with the flameout case of blast furnace gas direct discharge tower in Tangshan Steel new ar ea,this paper explores the flameout reasons of the discharge tower,defines the rectification measures and provides reference for other steelmakers.
作者 陈伟 陈晓伟 田朝 杨子凡 CHEN Wei;CHEN Xiaowei;TIAN Chao;YANG Zifan(The Power Dept.of Tangshan Iron and Steel Group Co.,Ltd.,Tangshan,Hebei 063000,China)
出处 《冶金动力》 2021年第5期24-26,共3页 Metallurgical Power
关键词 放散塔 高炉煤气 熄火 改造 blowdown tower blast furnace gas flameout transformation