图像引导放射治疗技术不同验证模式对头颈部肿瘤调强放疗摆位误差的影响 被引量:27

Effects of different verification modes of image-guided radiotherapy on the positioning errors of intensity-modulated radiotherapy for head and neck tumors
在线阅读 下载PDF
导出
摘要 目的探讨图像引导放射治疗(IGRT)技术不同验证模式对头颈部肿瘤调强放疗摆位误差的影响。方法选择20例行调强放疗的头颈部肿瘤患者,根据接受的验证方式分为A组及B组,每组各10例。A组患者行二维KV-KV位置验证,B组患者行三维锥体束CT(CBCT)位置验证。对比两组水平方向上的摆位误差及验证效果。结果两组患者水平方向上前后、头脚、左右位置的摆位误差比较,差异均无统计学意义(均P> 0. 05)。A组的验证时间及影像采集获取时间均短于B组(均P <0. 05),但B组的影像清晰度、配准区域、配准方式均优于A组。结论 IGRT技术的二维KV-KV验证模式和三维CBCT验证模式在水平方向上对摆位误差的验证效果相当。 Objective To explore the effects of different verification modes of image-guided radiotherapy(IGRT)on the positioning errors of intensity modulated radiotherapy for head and neck tumors.Methods A total of 20 patients with head and neck cancer who underwent intensity modulated radiotherapy were selected.According to the verification mode,patients were divided into group A or group B,with 10 cases in each group.2D KV-KV position verification was conducted in group A,while 3D cone beam CT(CBCT)position verification was conducted in group B.The difference in positioning error in the horizontal direction and verification effect were compared between the two groups.Results There were no statistically significants difference between the two groups in the horizontal positioning errors of anterior and posterior,head and foot,or left and right positions(all P >0.05).The validation time and image acquisition time A were shorter in group than in group B(all P<0.05),but the image clarity,registration area and registration mode were better in group B than in group A.Conclusion 2D KV-KV verification mode and 3D CBCT verification mode of IGRT have similar verification effects on positioning errors in horizontal direction.
作者 吴冰 马广栋 王亮和 WU Bing;MA Guang-dong;WANG Liang-he(Department of Radiotherapy Center,Renmin Hospital of Wuhan University,Wuhan 430060,China)
出处 《广西医学》 CAS 2019年第1期63-66,共4页 Guangxi Medical Journal
关键词 图像引导放射治疗 头颈部肿瘤 摆位误差 位置验证 水平方向 Image-guided radiation therapy Head and neck tumor Positioning error Position verification Horizontal direction
  • 相关文献

参考文献4

二级参考文献61

  • 1李丹,邓小武,包尚联.MVCT图像引导调强放疗在线检验靶区位置及修正剂量分布的临床应用[J].中华放射肿瘤学杂志,2005,14(6):508-511. 被引量:4
  • 2戴建荣,胡逸民.图像引导放疗的实现方式[J].中华放射肿瘤学杂志,2006,15(2):132-135. 被引量:184
  • 3王艳阳,傅小龙.CT在影像引导下放疗中应用的历史与现状[J].中国癌症杂志,2006,16(6):448-453. 被引量:22
  • 4Uematsu M, Akira S, Kazuhiko T, et al. Focal, high dose, and fractionated modified stereotactic radiationtherapy for lung carcinoma patients[J]. Cancer, 1998,82:1062-1070.
  • 5Bijhold J, van Herk M, Vijlbriet R, et al. Fast evaluation ol patient setup during radiotherapy by aligning features in portal and simulator images[J] .Phys Med Biol, 1991, 36(12): 1665- 1679.
  • 6van Herk M. Errors and margins in radiotherapy [J]. Semin Radiat Oneol, 2004,14:52 - 64 .
  • 7van Herk M, Remeijer P, Lebesque JV. Inclusion ot geometric us - certainties in treatment plan evaluation [J]. Int J Radiat Oncol Biol Phys, 2002, 52:1407-1422.
  • 8Jin JY, Ajlouni M, Chen Q, et al. A technique of using gated - CT images to determine internal target volume (ITv)for fractionated stereotactic lung radiotherapy [ J ]. Radiother Oncoi, 2006, 78 : 177 - 184.
  • 9Yah D, Lockman D, Martinez A, et al. Computed tomography guided management of interfractional patient vafiation[J]. Semin Radiat Oncol, 2005,15:168 - 179.
  • 10Hurkmans CW, Remeijer P, Lebesque JV, et al. Set - up verification using portal images, review of current clinical practice [ J]. Radiotherapy and Oncology,2001, 58(2) : 105 - 120.

共引文献59

同被引文献219

引证文献27

二级引证文献50

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部