期刊文献+

双能CT技术在小尺寸青铜器病害诊断中的应用研究 被引量:6

Application Research of Dual Energy CT Technology in Defect Diagnosis for Small Size Bronze
在线阅读 下载PDF
导出
摘要 双能计算机断层成像(CT)技术具有同时对物质结构和成分进行重建的能力,已被广泛应用于医疗、工业等领域。本文将双能CT技术引入至文物保护中,选取两种小尺寸青铜器腐蚀病害(密闭中空物体内表面病害和实心物体内部病害)作为研究对象。研究结果表明,重建结果的相对误差在10%以内,初步验证该方法可为文物保护人员更进一步了解病害腐蚀情况、制定有效的文物修复方案提供依据。 The dual energy computed tomography(CT)technology has strong identification capabilities for both structure and composition,which has been widely used in medical,industrial and other fields.In this paper,the dual energy CT technology was put into the cultural protection field,and two small size bronze corrosion defects(the defects are respectively in a sealed hollow inner surface and inside a solid object)were selected.The results show that the reconstruction relative error is within 10%.The preliminary results can be used to understand corrosions better and develop more effective rehabilitation plan for cultural protection researchers.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2015年第10期1909-1913,共5页 Atomic Energy Science and Technology
基金 国家自然科学基金青年科学基金资助项目(11305073)
关键词 小尺寸 青铜器 双能CT 病害 诊断 small size bronze dual energy CT defect diagnosis
  • 相关文献

参考文献20

  • 1GETTENS RJ. The freer Chinese bronzes, Vol. IT: Technical studies[M]. Washington D. C.:[so n.J, 1969.
  • 2杨军昌,韩汝玢.X光照相技术在文物及考古学研究中的应用[J].文物保护与考古科学,2001,13(1):55-60. 被引量:34
  • 3朱博雅.x射线检测技术在宝鸡弓鱼国墓地青铜器研究中的应用[D].北京:北京大学,2007.
  • 4吕淑贤.晋侯墓地青铜器铸造工艺的X射线成像检测分析[D].北京:北京大学,2009.
  • 5GAO Hcwei , ZHANG Li, CHEN Zhiqiang , et al. Beam hardeningcorrection for middle-energy industrial computerized tomography[J]. IEEE Transactions on Nuclear Science, 2006, 53(5): 2 796-2 807.
  • 6GAO Hewei , ZHANG Li, CHEN Zhiqiang , et al. Application of X-ray CT to liquid security inspection: System analysisand beam hardening correction[J]. Nuclear Instruments and Methods in Physics Research A, 2007, 5790): 395-399.
  • 7GREGORY D S, ROBINJ H C. Raman microscopy in archaeological science[J].Journal of Archaeological Science, 2004, 31: 1 137-1 160.
  • 8FU Qianli,]IN Pujun , LING Xue, et al, Preliminary study of corrosion status on bronzes excavated from Qin dynasty tombs at Xinfeng Town in China[J].Journal of Corrosion, 2012, ID: 150380.
  • 9CHRIST G. Exact treatment of the dual-energy method in CT using polyenergetic X-ray spectra[J]. Physics in Medicine and Biology, 1984, 29 (2): 1 501-1 510.
  • 10STEENBEEKJ C M, KUUK C, GRASHUISJ L, et al. Selection of fat-equivalent materials in post processing dual-energy quantitative CT[J]. Medical Physics, 1992, 19(4): 1051-1 056.

二级参考文献20

  • 1张世贤.从毛公鼎的真伪鉴别展望中国古器物学的研究(上)[J].文物保护与考古科学,1994,6(2):39-42. 被引量:7
  • 2杨文宗.戴家湾陶鬲修复前的诊断分析与制作工艺[J].文博,1999(1):89-93. 被引量:3
  • 3韩汝玢.电子显微技术在冶金考古中的应用[J].电子显微学报,1997,16(3):229-237. 被引量:3
  • 4R Engler and W. D. Friedman, Review of dual-energy computed tomography techniques, Mater. Eval., vol. 48, no. 5, pp. 623-629, 1990.
  • 5R. E. Alvarez, J. A. Seibert, and S. K. Thompson, Comparison of dual energy detector system performance, Med. Phys., vol. 31, no. 3, pp. 556-565, 2004.
  • 6G. U. Rao, I, Yaghmai, A. O. Wist, and G. Arora, Systematic errors in bone-mineral measurements by quantitative computed tomography, Med. Phys., vol. 14, no. 1, pp. 62-69, 1987.
  • 7S. Oelckers and W. Graeff, In situ measurement of iron overload in liver tissue by dual-energy methods, Phys. Med. Biol., vol. 41, no. 7, pp. 1149-1165, 1996.
  • 8A. J. Coleman and M. Sinclair, A beam-hardening correction using dual-energy computed tomography, Phys. Med. BioL, vol. 30, no. 11, pp. 1251-1256, 1996.
  • 9Z. R. Ying, R. Naidu, and C. R. Crawford, Dual energy computed tomography for explosive detection, J. X-ray Sci. Technol., vol. 14, pp. 235-256, 2006.
  • 10Z. R. Ying, R. Naidu, K. Guilbert, D. Schafer, and C. R. Crawford, Dual energy volumetric x-ray tomographic sensor for luggage screening, in Proc. q[" IEEE Sens. Appl. Swnp., 2007, pp. 1-6.

共引文献35

同被引文献91

引证文献6

二级引证文献14

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部