期刊文献+

Optimization of the Water-Cooled Structure for the Divertor Plates in EAST Based on an Orthogonal Theory

Optimization of the Water-Cooled Structure for the Divertor Plates in EAST Based on an Orthogonal Theory
在线阅读 下载PDF
导出
摘要 An orthogoual experimental scheme was designed for optimizing a water-cooled structure of the divertor plate. There were three influencing factors: the radius R of the water- cooled pipe, and the pipe spacing L1 and L3. The influence rule of different factors on the cooling effect and thermal stress of the plate were studied, for which the influence rank was respectively R 〉 L1 〉 L3 and L3 〉 R 〉 L1. The highest temperature value decreased when R and L1 increased~ and the maximum thermal stress value dropped when R, L1 and L3 increased. The final optimized results can be summarized as: R equals 6 mm or 7 mm, L1 equals 19 mm, and L3 equals 20 mm. Compared with the initial design, the highest temperature value had a small decline~ and the maximum thermal stress value dropped by 19~ to 24~. So it was not ideal to improve the cooling effect by optimizing the geometry sizes of the water-cooled structure, even worse than increasing the flow speed, but it was very effective for dropping the maximum thermal stress value. The orthogoaal experimental method reduces the number of experiments by 80%, and thus it is feasible and effective to optimize the water-cooled structure of the divertor plate with the orthogonal theory. An orthogoual experimental scheme was designed for optimizing a water-cooled structure of the divertor plate. There were three influencing factors: the radius R of the water- cooled pipe, and the pipe spacing L1 and L3. The influence rule of different factors on the cooling effect and thermal stress of the plate were studied, for which the influence rank was respectively R 〉 L1 〉 L3 and L3 〉 R 〉 L1. The highest temperature value decreased when R and L1 increased~ and the maximum thermal stress value dropped when R, L1 and L3 increased. The final optimized results can be summarized as: R equals 6 mm or 7 mm, L1 equals 19 mm, and L3 equals 20 mm. Compared with the initial design, the highest temperature value had a small decline~ and the maximum thermal stress value dropped by 19~ to 24~. So it was not ideal to improve the cooling effect by optimizing the geometry sizes of the water-cooled structure, even worse than increasing the flow speed, but it was very effective for dropping the maximum thermal stress value. The orthogoaal experimental method reduces the number of experiments by 80%, and thus it is feasible and effective to optimize the water-cooled structure of the divertor plate with the orthogonal theory.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第5期435-440,共6页 等离子体科学和技术(英文版)
基金 supported by National Basic Research Program of China(973 Program)(No.2013GB102000)
关键词 orthogonal theory divertor plate water-cooled structure cooling effect thermal stress OPTIMIZATION orthogonal theory, divertor plate, water-cooled structure, cooling effect, thermal stress, optimization
  • 相关文献

参考文献1

二级参考文献5

  • 1蒋婧,冉红,刘德权,程发银,白刚毅.HL-2A偏滤器结构改造及热负荷分析[J].核聚变与等离子体物理,2006,26(1):22-26. 被引量:4
  • 2Wessen J. Tokamak [M]. Oxford: Clarendon Press, 1987: 435-438.
  • 3Sizheng Zhu, Xuejun Zha. Numerical predictions for the HT-TU divertor [Z]. 15th PSI, Gifu Japan, 2002.
  • 4Mansur L K., Ishino S, Lemaignan C, et al. Journal of Nuclear Material [M]. UK: Thomson Reuters 2001: 290-293.
  • 5Song Y T, Yao D M, Wu S T, et al. Thermal and mechanical analysis of the EAST plasma facing components [J]. Fusion Engineering and Design, 2005, 75-79: 499-503.