期刊文献+

近红外光谱法快速测定呋喃妥因肠溶片的含量 被引量:4

Development of a near IR method for rapid determination of nitrofurantoin enteric tablets
在线阅读 下载PDF
导出
摘要 目的利用近红外漫反射光谱分析技术和化学计量学方法对呋喃妥因肠溶片进行无损、快速定量分析。方法以在全国范围内不同企业生产的呋喃妥因肠溶片为分析对象,用光纤探头测定近红外漫反射光谱,通过偏最小二乘法(PLS)建立数学模型,考察了不同建模谱段和图谱预处理方法的选择对模型预测能力的影响。结果所建模型具有较好的预测能力,验证集样品的NIR预测值与参考值间的相关系数(R2)为95.25%,平均预测偏差为1.72,预测均方差(RMSEP)为2.15。结论该方法快速、简便、结果准确,可用于药品现场快速分析。 Objective To develop a method for rapid, non-destroyed determination of nitrofurantoin enteric tablets by near infrared diffuse reflectance spectroscopy (NIRDRS) technology and chemometrics. Methods The NIRDRS of nitrofurantoin enteric tablets from different pharmaceutical factories in China were determined by a fiber optic probe. The partial least square(PLS) was applied to establish the model. High performance liquid chromatography (HPLC) was the reference method used for this study. Results The model had a good performance for prediction. The correlation coefficient( R2) was 95: 25% ,the mean difference of prediction for test sets was 1.72, and the root mean square error of prediction(RMSEP) was 2.15. Conclusion The method is rapid , simple and exact, which can be applied to on-the-spot drug rapid determination.
作者 李小安 单敏
出处 《安徽医药》 CAS 2012年第9期1263-1265,共3页 Anhui Medical and Pharmaceutical Journal
关键词 呋喃妥因肠溶片 近红外漫反射(NIRDRS)光谱 定量分析 nitrofurantoin enteric tablets near infrared diffuse reflectance spectroscopy (NIRDRS) quantitative analysis
  • 相关文献

参考文献7

二级参考文献47

  • 1汤彦丰,张卓勇,范国强.中草药大黄的近红外光谱和人工神经网络鉴别研究[J].光谱学与光谱分析,2004,24(11):1348-1351. 被引量:56
  • 2逄焕欢,冯艳春,胡昌勤,相秉仁.不同生产厂家注射用头孢哌酮钠含量测定的近红外定量模型的建立[J].光谱学与光谱分析,2006,26(12):2214-2218. 被引量:32
  • 3Bellamy LJ, Nordon A, Littlejohn D. Effects of particle size and cohesive properties on mixing studied by non-contact NIR[J]. Intern J Pharmaceut, 2008, 361: 87-91.
  • 4Cogdill RP, Dardenne P. Least squares support vector machines for chemometrics: an introduction and evaluation[J]. J Near Infrared Spectrosc, 2004 ,12 (2) : 93-100.
  • 5Roggo Y, Chalus P, Maurer L, et al. A review of near infrared spectroscopy and chemometricin pharmaceutical technologies [J]. J Pharmaceut & Biomed Anal, 2007, 44 : 683-700.
  • 6DeBeer TRM , Bodson C, Dejaegher B. Raman spectroscopy as a process analytical technology (PAT) tool for the in-line monitoring and understanding of a Powder blending process[J]. J Pharmaceut and Biomed A- nal, Accepted Manuscript, 2008,7: 25.
  • 7Blanco M, Alcala M. Contentuniformity andtablet hardness testing of intact pharmac tablets by near infrared spectroscopy-A contribution to process analytical technologies[J]. Anal Chin Acta , 2006, 557: 353-359.
  • 8Zheng Yiwu, Lai Xuxin, Bruun SW, et al. Determination of moisture content of lyophilized allergen vaccines by NIR spectroscopy[J]. J Pharmaceut and Biomed Anal, 2008, 46:592-596.
  • 9White JG. On-line moisture detection for a microwave vacuum dryer[J]. Pharm Res,1994, 11 (5) :728.
  • 10Leuenberger H, Puchkov M, Krausbauer E,et al. Manufacturing pharmaceutical granules: Is the granulation endpoint a myth? [J]. Powder Technol, 2008, 59, 123-131.

共引文献126