期刊文献+

盐酸环喷托酯和阿托品对远视儿童睫状肌麻痹效果的比较 被引量:1

Comparative study on the effects of cycloplegia between cyclopentolate hydrochloride and atropine in children with hyperopia
在线阅读 下载PDF
导出
摘要 目的:比较盐酸环喷托酯与阿托品对远视儿童睫状肌麻痹效果,以评估盐酸环喷托酯的临床使用价值。方法:对96例192眼远视儿童进行观察,先用盐酸环喷托酯滴眼液,后用阿托品眼膏,分析比较两种药物睫状肌麻痹后的验光结果和观察药物的不良反应。结果:两组睫状肌麻痹后的验光结果差异无显著性(P>0.05)。盐酸环喷托酯组未见明显药物不良反应,低于阿托品组(12.5%)。结论:盐酸环喷托酯是一种强效、快速且安全的睫状肌麻痹剂,值得临床推广应用,尤其适合远视儿童的睫状肌麻痹验光检查。 AIM:To compare the cycloplegic effect of cyclopentolate hydrochloride and atropine in children with hyperopia.METHODS:Ninety-six children with hyperopia(192 eyes) were subjected to cycloplegic refractometry by cyclopentolate hydrochloride followed with atropine,to compare and analyze the refractive results and systemic side reactions.RESULTS:The effect on refractive results had no significant difference in two medicines(P0.05).As for incidence rate of systemic side effects,cyclopentolate hydrochloride was lower than atropine(12.5%).CONCLUSION:The cyclopentolate hydrochloride is a powerful,quick and safe cycloplegia medicine,especially for children with hyperopia.
作者 胡平会
出处 《国际眼科杂志》 CAS 2011年第11期2047-2048,共2页 International Eye Science
关键词 盐酸环喷托酯 阿托品 睫状肌麻痹 远视 儿童 cyclopentolate hydrochloride atropine cycloplegia hyperopia children
  • 相关文献

参考文献9

二级参考文献21

  • 1蒋丽琴,吕帆,周翔天,赵海岚,王瑞卿,瞿佳.环戊通松弛豚鼠睫状肌的调节作用[J].眼视光学杂志,2004,6(4):203-205. 被引量:9
  • 2范传峰,丛爱宁,范惠芝.青少年应用复方托品酰胺散瞳前后电脑验光的结果分析[J].国际眼科杂志,2006,6(6):1455-1456. 被引量:9
  • 3任志凤,马蕾.青少年阿托品和复方托品酰胺散瞳验光效果临床观察[J].山西医科大学学报,2007,38(3):258-259. 被引量:7
  • 4廖斌,卢炜.两种散瞳剂在弱视儿童验光中的应用探讨[J].国际眼科杂志,2007,7(3):868-869. 被引量:11
  • 5Zhao J, Mao J, Luo R, et al . Accuracy of noncyciopiegic autorefraction in school-age children in China. Optom Vis Sci 2004;81 (1):49-55.
  • 6Prokurina OV. Cycloplegic effectiveness of cyclopentolate and tropicamide preparations compared with atropinization.Vis Oftalmol 2002;118 (6) :42-45.
  • 7FAN D S,RAO S K,NG J S,et al.Comparative study on the safety and efficacy of different eycioplegie agents in children with darkly pigmented irides[J].Clin Experiment Ophthal,2004,32(5):462-467.
  • 8ARUP K,ROY J,KEITH G.The kinetics and mechanism of the hydrolysis of cyclopentolate hydroehloride in alkaline solutions[J].Int J Pharmaceutics,1995,120(1):169-178.
  • 9HOFMEISTER E M,KAUPP S E,SCHALLHORN S C,et al.Comparison of tropicamide and cyclopentolate for cycloplegic refractions in myopic adult refractive surgery patients[J].J Cataract Refract Surg,2005,33(4):694-700.
  • 10MANNY R E,FERN K D,ZERVAS H J,et al.1%Cyclopentolate hydrochloride:another look at the time course of cycloplegia using an objective measure of the accommodative response[J].Optom Vis Sci,1993,70(8):651-665.

共引文献47

同被引文献29

  • 1Heifer KJ, Shammas HJ, Savini G. Comparison of 2 laser instruments for measuring axial length[J]. J Cataract Refract Surg, 2010,36 (4) : 644-648.
  • 2Santodomingo-Rubido J, Mallen EAH, Gilmartin B, et al. A new non-contact optical device for ocular biometry[J]. Br J Ophthalmol, 2002,86 (4) :458-462.
  • 3Carkeet A, Saw SM, Gazzard G, et al. Repeatability of IOLMaster biometry in children[J]. Optom Vis Sci,2004,81(11): 829-834.
  • 4Vogel A, Dick HB, Krummenauer F. Reproducibility of optical biometry using partial coherence interferometry: intraobserver and interobserver reliability[J]. J Cataract Refr act Surg,2001, 27 (12) : 1961-1968.
  • 5Buckhurst PJ, Wolffsohn JS, Shah S, et al. A new optical low coherence reflectometry device for ocular biometry in cataract patients[J]. Br J Ophthalmol,2009,93(7):949-953.
  • 6Cruysberg LPJ, Doors M, Verbakel F, et al. Evaluation of the Lenstar LS 900 non-contact biometer[J]. Br J Ophthalmol,2010, 94(1) : 106-110.
  • 7Zhao J, Chen Z, Zhou ZM, et al. Evaluation of the repeatability of the Lenstar and comparison with two other non-contact biometric devices in myopes[J]. Clin Exp Optom,2013,96 (1): 92-99.
  • 8Ucakhan OO, Akbel V, Biyikli curvature and anterior chamber Z, et al. Comparison of corneal depth measurements using the manual keratometer, Lenstar kS 900 and the Pentacam[J]. Middle East Afr J Ophthalmol,2013,20(3):201-206.
  • 9Shen PY, Zheng YF, Ding XH, et al. Biometric measurements in highly myopic eyes[J]. J Cataract Refract Surg,2013,39(2): 180-187.
  • 10Shammas H J, Hoffer KJ. Repeatability and reproducibility of biometry and keratometry measurements using a noncontact optical low-coherence reflectometer and keratometer[J]. Am J Ophthalmol, 2012,153 ( 1 ) : 55-61.

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...