摘要
单相PWM整流器作为串联H桥多电平变频器的有源前端,可以满足矿井提升机对电气传动系统能量双向流动能力的要求,但是其输出2次脉动电压使得网侧电流存在3次谐波。针对上述问题,提出了一种稳态误差前馈补偿的方法,即将输出直流电压的二倍频正弦误差信号补偿至直流电压给定信号,以减小电压脉动对电网电流畸变的影响。仿真及硬件实验验证了该方法的有效性。
To take single-phase PWM rectifier as AFE of cascaded H-bridge multi-level frequency converter can satisfy requirement that electric drive system of coal mine hoist must have capacity of bidirectional energy flowing,but there are third harmonic in its AC-side current because of the second ripple of output voltage.To slove the problem,a method of steady-state error feed-forward compensation was put forward,namely frequency-doubled sinusoidal error signal of output DC voltage is compensated to set signal of DC voltage in order to reduce influence of voltage ripple on distorted current of power grid.The results of simulation and hardware experiment showed that the method is effective.
出处
《工矿自动化》
2011年第8期75-78,共4页
Journal Of Mine Automation
关键词
提升机
电气传动
单相有源前端
直流电压脉动
网侧电流
前馈补偿
hoist
electric drive
single-phase AFE
ripple of DC voltage
AC-side current