期刊文献+

考虑非等温混合的能量集成水网络设计方法 被引量:7

Design method of heat integrated water networks considering non-isothermal mixing
在线阅读 下载PDF
导出
摘要 讨论了能量集成水网络中非等温混合对系统能量目标的影响,提出了分割温度的概念。对于同性混合,系统的公用工程需求量不会减少。对于异性混合,通过确定分割温度并比较分割温度以上区间混合流股的热量之和与低温区间所需的热量,可以准确确定系统公用工程会增加、减少或者保持不变。基于以上思想,得到了非等温混合规则。它能判断是否存在能量惩罚,以及如何通过设计混合温度来避免能量惩罚。结合改进的"分离系统"法,提出了一种系统化的能量集成水网络设计方法。 The effect of non-isothermal mixing on system energy target in heat integrated water networks was addressed, and the concept of "split temperature" was proposed. For homogeneous mixing, system utility requirement will not decrease. For heterogeneous mixing, it can identify whether system utility requirement would increase, decrease or keep the same, by locating the split temperature and comparing the cumulative heat of the mixing streams above the split temperature and the heat demand in the lower temperature intervals. Based on the ideas above, some rules of nonqsothermal mixing are presented, which could be used to estimate whether energy penalty exists or not, and to eliminate the penalty by designing new mixing temperatures. Combining them with improved "separate system", a systematic method is proposed to design energy efficient water networks.
出处 《化工学报》 EI CAS CSCD 北大核心 2010年第2期369-377,共9页 CIESC Journal
关键词 非等温混合 混合规则 能量惩罚 能量集成水网络 non-isothermal mixing mixing rules energy penalty heat integrated water networks
  • 相关文献

参考文献2

二级参考文献19

  • 1郑雪松,冯霄,沈人杰.具有最简结构水回用网络的优化[J].高校化学工程学报,2006,20(4):622-627. 被引量:10
  • 2冯霄,刘永忠,段海涛,张涛.通过改进网络结构提高多杂质水系统柔性的集成方法[J].化工学报,2006,57(8):1938-1942. 被引量:4
  • 3白洁,冯霄.水系统集成方法分析[J].化工进展,2006,25(12):1471-1476. 被引量:7
  • 4Savulescu L,Smith R.Simultaneous energy and water minimisation//AIChE Annual Meeting.Miami,1998
  • 5Savulescu L,Kim J,Smith R.Studies on simultaneous energy and water minimisation(Ⅰ):Systems with no water re-use.Chemical Engineering Science,2005,60(12):3279-3290
  • 6Savulescu L,Kim J,Smith R.Studies on simultaneous energy and water minimisation(Ⅱ):Systems with maximum re-use of water.Chemical Engineering Science,2005,60(12):3291-3308
  • 7Savulescu L,Sorin M,Smith R.Direct and indirect heat transfer in water network systems.Applied Thermal Engineering,2002,22(8):981-988
  • 8Sorin M,Savulescu L.On minimization of the number of heat exchangers in water networks.Heat Transfer Engineering,2004,25(5):30-38
  • 9Bagajewicz M,Rodera H,Savelski M.Energy efficient water utilization systems in process plants.Computers & Chemical Engineering,2002,26(1):59-79
  • 10Zheng Xuesong(郑雪松).Optimal mathematical model of water-using network with different structures[D].Xi'an:Xi'an Jiaotong University,2005.