期刊文献+

紫外-可见分光光度法测定右旋糖酐铁制剂中铁的含量 被引量:4

Content Determination of Fe in Iron Dextran Preparations by UV-VIS
原文传递
导出
摘要 目的:建立以紫外-可见分光光度法测定右旋糖酐铁制剂中铁含量的方法。方法:在酸性条件下,加热右旋糖酐铁溶液使Fe^(3+)游离后,用盐酸羟胺还原成Fe^(2+),再与邻二氮菲形成红色络合物,以紫外-可见分光光度法在510 nm波长处测定其含量。结果:Fe^(2+)检测浓度的线性范围为0.5~4.0μg·mL^(-1)(r=0.999 9);右旋糖酐铁片及其注射液的平均回收率分别为99.8% (RSD=0.52%)、99.7%(RSD=0.44%)。结论:本方法操作简便、结果准确,可用于该类制剂的含量测定。 OBJECTIVE: To establish the ultraviolet visible spectrophotometry(UV - VIS) for the determination of Fe content in iron dextran preparations. METHODS: Under the acidic condition, Fe^3+ was dissociated from iron dextran solution by heating, then Fe^3+ was deoxidized into Fe^2 + by hydroxylamine hydrochloride, and red Fe^2+ -orthophenanthroline complex was formed through combination with o - phenanthroline. The content of the Fe^2 + - ortbopbenanthroline complex was determined by UVVIS at a wavelength of 510 nm. RESULTS: The linear range of Fe^2 + was 0.5-4.0 μg · mL ^-1 (r = 0.999 9). The average recoveries of two preparations (tablets and injection) of iron dextran were 99.8% (RSD = 0.52%) and 99.7% (RSD = 0.44% ), respectively. CONCLUSION: The UV-VIS method is simple, accurate in results and applicable for the determination of iron dextran preparations.
作者 赵云 叶红
机构地区 浙江省台州医院
出处 《中国药房》 CAS CSCD 北大核心 2009年第10期788-789,共2页 China Pharmacy
关键词 紫外-可见分光光度法 右旋糖酐铁 制剂 含量测定 UV - VIS Iron dextran Preparations Content determination