摘要 目的探讨肱骨近端锁定钢板(LPHP)内固定治疗肱骨近端骨折的临床疗效。方法采用切开复位、LPHP内固定治疗31例肱骨近端Neer二、三、四部分骨折患者,术后早期进行功能锻炼。结果31例骨折全部愈合,愈合时间3~6(3.5±1)个月。术后随访6~18(10±3)个月,无骨折不愈合、钢板松动、感染等并发症,1例四部分骨折出现肱骨头缺血坏死。按Neer评分标准评分:优20例,良7例,可3例,差1例,优良率87.1%。结论LPHP内固定治疗肱骨近端骨折,固定牢固,允许早期功能锻炼,疗效满意。 Objective To investigate the clinical effect of locking plate fixation in the treatment of proximal humerus fracture. Methods 31 cases, including Neer two,three, four-part proximal humerus fractures were treated by the open reduction and locking plate fixation, early function exercise after surgery. Results All 31 cases were healed, and the average healing time was 3 -6(3.5 ± 1 ) months. All cases were followed up for6 -18( 10 ±3) months. No nonunion, plate loosening, or infection was found. According to Neer scoring system, the results were excellent in 20 cases, good in 3,and poor in 1. The excellent and good rate was 87. 1%. Conclusions The treatment of the proximal humerus fractures by locking plate fixation can provide reliable fixation and allow early exercise.
出处 《临床骨科杂志》 2008年第6期551-552,共2页 Journal of Clinical Orthopaedics
关键词 肱骨近端骨折 锁定钢板 骨折固定术 proximal humeral fractnres locking plate fracture fixation internal
  • 相关文献

参考文献3

二级参考文献24

  • 1Zuekerman JD, Checroun AJ. Fractures of the humerus: diagnosis and management, In: Iannoti JP, Williams GR Jr. Disorders of the shoulder: diagnosis and mangement. 1st eds. Philadephia: Lippincott Williams & Wilkins, 1999. 639-685.
  • 2Neer CS 2nd. Displaced proximal humeral fracture. Part Ⅱ. Treatment of the three-part and four-part displacement. J Bone Joint Surg (Am), 1970, 52: 1090-1103.
  • 3Hawkins RJ, Kiefer GN. Internal fixation techniques for proximal humeral fractures. Clin Orthop, 1987, (223): 77-85.
  • 4Hawkins R J, Bell RH, Gurr K. The three-part fracture of the proximal of the humerus: operative treatment. J Bone Joint Surg (Am),1986, 68: 1410-1414.
  • 5Kristiansen B, Kofoed H. Transeutaneous reduction and external fixation of displacted fracture of proximal humerus: a contorlled clinical trial. J Bone Joint Surg (Br), 1988, 70: 821-824.
  • 6Kristiansen B, Christensen SW. Plate fixation of proximal humeral fractures. Acta Orthop Seand, 1986, 57: 320-323.
  • 7Bigliani LU, Flatow EL, Pollock RG. Fractures of the proximal huerus. In: Rockwood CA, Green DP, Bucholz RW, et al. Fractuers in adults. 4th eds. Philadephia: Lippincott Raven, 1996. 1055-1107.
  • 8Jaberg H, Warner J J, Jakob RP. Percutaneous stabilization of unstable fractures of the humerus. J Bone Joint Surg (Am), 1992, 74:508-515.
  • 9Kocialkowski A, Wallace WA. Closed percutaneous K-wire stabilization for displacted fractures of the surgical neck of the humerus.Injury, 1990, 21: 209-212.
  • 10Resch H, Povacz P, Frohlich R, et al. Percutaneous fixation of the three- and four-part fractures of the proximal humerus. J Bone Joint Surg (Br), 1997, 79: 295-300.

共引文献204

同被引文献45

  • 1张鹏翼,黄煌渊,陈文钧.肱骨近端骨折的手术治疗进展[J].上海医学,2004,27(12):946-948. 被引量:63
  • 2董黎强,曹根洪,沈建国,王昌兴.三叶草钢板治疗难复性肱骨近端骨折脱位[J].中国骨伤,2005,18(4):226-226. 被引量:5
  • 3COURT-BROWN C M, MCQUEEN M M. The relationship between fractures and increasing age with reference to the proximal humerus[J].urrOrthop. 2002,16:213-222.
  • 4GARDNER M J,WEIL Y,BARKER J U,et al. The importance of medial support in locked plating of proximal humerus fractures [J]. J Orthop Trauma,2007,21(2) :185-191.
  • 5KRISTIANSEN B, CHRISTENSEN S W. Plate fixation of proximal humeral fraetures[J ]. Aeta Orthop Scand, 1986, 57:320- 323.
  • 6PAAVOLAINEN P, BJORKENHEIM J M, SLATIS P,et al. Operative treatment of severe proximal humeral fractures[J ]. Acta Orthop Scand, 1983,54(3) ":374-379.
  • 7ESSER R D. Treatment of three and four part fractures of the proximal humeruswith amodified cloverleaf plate[J ]. J Orthop Trauma, 1994,8(1) :15-22.
  • 8WANNER G A,WANNER 2S CHMID E,ROMERO J,et al . Internal fixation of displaced proximal humeral fractures with two one 2third tubular plates[J ]. J Trauma,2003,54(3):536-544.
  • 9MEIER RA, MESSMER P, REGAZZONI P, et al. Unexpected high complication rate following internal fixation of unstable proximal humerus fractures with an angled blade pate [J ]. J Or thop Trauma, 2006,20(4) : 2532-2560.
  • 10WAISH S, REINDL R, HARVER E. et al. Biomechanical com parison of a unique locking plate versus a standard plate for in ternal fixation of proximal humerus fractures in a cadaveric rood el[J].n Biomech. 2006,21 (10) : 1027.

引证文献8

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部