螺距和外形对纯钛螺纹种植体初期稳定性的影响 被引量:8

The influence of implant type and pitch on initial stability of pure titanium screw-implant
原文传递
导出
摘要 目的:测量钛种植体植入扭矩(ITV)和稳定系数(ISQ),分析不同螺距和外形对种植体初期稳定性的影响。方法:将螺距分别为0.8mm、1.2mm、1.6mm的柱状和两种锥形的机械表面钛种植体各12个植入新鲜的猪椎骨中,测量植入时扭矩和植入后种植体的稳定系数。结果:0.8mm螺距种植体的植入扭矩(40.66±2.46)大于1.2mm(38.33±2.60)和1.6mm(38.05±2.83)者(p<0.05),其稳定系数(74.38±3.61)也大于1.2mm(71.91±4.33)和1.6mm(71.44±3.78)者(P<0.05);柱状、TaperI型和TaperII型种植体的植入扭矩(分别为38.90±2.88、38.95±2.68和39.20±3.08)未见明显差异(p>0.05),柱状种植体的稳定系数(73.91±4.70)大于两种锥形种植体(71.90±3.90和71.91±3.33),(p<0.05);种植体的螺距和外形对其初期稳定性的影响无交互作用。结论:0.8mm螺距种植体的初期稳定性优于1.2mm和1.6mm者,柱状种植体的初期稳定性优于锥形种植体。 Objective: To analyze the influence of different types and pitches on implant initial stability by measuring insertion torque and implant stability quotient of titanium implant, Method: Insert three types (one cylinder and two kinds of taper-shape) of mechanical surface titanium implants with different pitches (0.8 mm. 1.2 mm and 1.6 mm) into fresh pork vertebrae,then measure their ITV and ISQ. Result:The 0.8 mm pitch implant had better initial stability than the 1.2 mm and 1.6 mm by both ITV (40.66±2.46,38.33±2.60 and 38.05±2.83)and ISQ (74.38±3.61,71.91±4.33 and 71.44±3.78) measurements (P〈0.05) : There were no significant initial stability differences between the cylinder and the two kinds of taper implants by ITV (38.90±2.88,38.95±2.68 and 39.20±3.08)measurements (P〉0.05),but the cylinder implants had better initial stability than the other two by ISQ (73.91 ±4.70,71.90±3.90 and 71.91 ±3.33)measurements (P〈0.05) : There were no mutual effect between implant type and pitch. Conclusion: The 0.8 mm pitch implant had better initial stability than the 1.2 mm and 1.6 mm pitches, and the cylinder type implant had better initial stability than the taper types.
出处 《临床口腔医学杂志》 2008年第7期433-435,共3页 Journal of Clinical Stomatology
关键词 牙种植体 初期稳定性 植入扭矩 共振频率分析 种植体稳定系数 外形 螺距 implant initial stability:insertion torque value (ITV) implant stability quotient (ISQ):resonanee frequency analysis (RFA) type pitch.
  • 相关文献

参考文献13

  • 1Mish CE. Contemporary implant dentistry[M]. 2nd ed. st. Louis: Elsevier; 1997.54.
  • 2Beer A, Gahleitner A, Holm A,et al. Adapted preparation technique for screw-type implants:explorative in vitro pilot study in a porcine bone model[J]. Clin. Oral Impl. Res, 2007, 18(1) : 103-107.
  • 3Meredith N. Assessment of implant stability as a prognostic determinant [J]. Int J Prosthodont. 1998, 11 (5) : 491-501.
  • 4Turkyilmaz, Ballibaba. A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Branemark system implants [J]. Journal of Oral Rehabilitation, 2006, 33 (10) : 754-759.
  • 5Beer A, Gahleitner A, Holm A, et al. Correlation of insertion torques with bone mineral density from dental quantitative CT in the mandible[J]. Clin Oral Implants Res, 2003, 14 (5) : 616-20.
  • 6Tricio J,Van Steenberghe D,Rosenberg D,et a l. Implant stability related to insertion torque force and bo nedensity: An in vitro stud) [J] .Prosthet Dent, 1995,74 (6) : 608 - 612.
  • 7Aparicio C,Rangert B,Sennerby L. Immediate early loading of dental implants report from the sociedad espanola de implantes world congress consensus meeting in barcelona spain.2002 [J]. Clin Implant Dent Relat Res, 2003,5 (1) : 57 - 60.
  • 8Huang HM,Chiu CL, Yeh CY,et al. Early detection of implant healing process using resonance frequency analysis [J]. Clin Oral Implants Res, 2003, 14 (4) : 437 - 443.
  • 9Cullinane DM,Einhorn TA. Biomechanics of bone Bilezikian JP, Raisz LG, Rodan GA. Principles of bone biology [M]. San Diego: Academic Press, 2002.17-32.
  • 10孔亮,刘宝林,胡开进,李德华,宋应亮,马攀,杨劲.螺纹种植体螺距的优化设计和应力分析[J].华西口腔医学杂志,2006,24(6):509-512. 被引量:23

二级参考文献13

  • 1Cehreli M,Duyck J,De Cooman M,et al.Implant design and interface force transfer.A photoelastic and strain-gauge analysis[J].Clin Oral Implants Res,2004,15(2):249-257.
  • 2Ivanoff C J,Grondahl K,Sennerby L,et al.Influence of variations in implant diameters:A 3-to 5-year retrospective clinical report[J].Int J Oral Maxillofac Implants,1999,14(2):173-180.
  • 3Brunski JB.Biomechanical considerations in dental implant design[J].Int J Oral Implantol,1988,5(1):31-34
  • 4Timoshenko SP,Goodier JN.Theory of elasticity[M].Singapore:McGraw-Hill International Book Co.,1984:15-40.
  • 5Zienkiewicz OC.The finite element method in engineering science[M].4th ed.New York:McGraw-Hill International Book Co.,1989:100-120.
  • 6Kitamura E,Stegaroiu R,Nomura S,et al.Biomechanical aspects of marginal bone resorption around osseointegrated implants:Considerations based on a three-dimensional finite element analysis[J].Clin Oral Implants Res,2004,15(4):401-412.
  • 7Cook SD,Klawitter JJ,Weinstein AM.A model for the implantbone interface characteristics of porous dental implants[J].J Dent Res,1982,61(8):1006-1009.
  • 8Borchers L,Reichart P.Three-dimensional stress distribution around a dental implant at different stages of interface development[J].J Dent Res,1983,62(2):155-159.
  • 9Colling EW.The physical metallurgy of titanium alloys[M].American Society for Metals,Ohio:Metals Park,1984:53-78.
  • 10Lewinstein I,Banks-Sills L,Eliasi R.Finite element analysis of a new system (IL) for supporting an implant-retained cantilever prosthesis[J].Int J Oral Maxillofac Implants,1995,10 (3):355-366.

共引文献22

同被引文献121

引证文献8

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部