负压真空气垫对精确放疗体位固定的影响 被引量:17

Effect of Negative Pressure Vacuum Air Cushion in Precise Radiotherapy
在线阅读 下载PDF
导出
摘要 目的:探讨负压真空气垫固定技术在肿瘤精确放疗中的临床应用价值及存在的问题。方法:采用真空气垫体位固定技术,利用激光线标出真空袋与身体之间的关系,在患者的相对应部位和真空袋作连线标记,以便患者体位重复。在放疗摆位投照实施前后,用射野标尺测量验证射野前后的靶区各点的移动情况,并进行比较。结果:根据真空气垫标记摆位,患者体位重复性误差<2 mm。患者在0°位置摆位误差<2 mm。验证适形照射野在模拟机下灯光野深度在治疗计划所给深度的平均误差在2~3 mm以内。结论:在开展肿瘤精确放疗过程中,用真空气垫固定体位方法的偏差幅度均明显减少,其临床应用价值显而易见。 Objective To discuss the clinical value and existing problems of the fixation technology of negative pressure vacuum bag in tumor precise radiotherapy. Methods The fixation technology of vacuum bag was utilized. The relations between the vacuum-bag and the body were marked by laser beam. The corresponding parts in the patient were linked with vacuum-bag by marks for the repetition of patient's body posture. The confirmation method was used to compare the target areas measured by radiation field scale before and after the body position projection. Results The repeatability errors of patient's body posture was not more than 2 mm. The position error at 0° was not more than 2 mm. The average error between the light depth of the suitable shape under the simulator to the treatment plan was 2-3mm. Conclusion It is indicated that in the development of tumor precise radiotherapy process, errors are obviously reduced by using the vacuum air cushion to fix body posture. This method should be applied widely for its high clinical value.
作者 王巍
出处 《医疗卫生装备》 CAS 2008年第5期91-92,共2页 Chinese Medical Equipment Journal
关键词 精确放疗 负压真空气垫 体位固定技术 precise radiotherapy vacuum bag technique of immobilization
  • 相关文献

参考文献6

二级参考文献18

  • 1孔令玲,唐虹.保证三维适形放疗精度的简易方法[J].中华放射肿瘤学杂志,2005,14(2):139-140. 被引量:11
  • 2戴建荣 胡逸民.射野影像系统.肿瘤放射物理学[M].北京:原子能出版社,1999.463-466.
  • 3Mitine C,Radiother Oncol,1999年,52卷,19页
  • 4戴建荣,肿瘤放射物理学,1999年,463页
  • 5Bijhold J,Radiother Oncol,1992年,24卷,261页
  • 6Lebesque J V,Radiother Oncol,1992年,23卷,198页
  • 7Meertens H,Phys Med Biol,1990年,35卷,299页
  • 8Rosenzweig KE,Sim S,Mychalclczak B,et al.Elective nodal irradiation in treatment of non-small cell lung cancer with three-dimentional conformal radiation therapy (3D-CRT)[J]. Int J Radiat Oncol Biol Phys,2001,50:681-685.
  • 9Graham WV, Purdy JA,Emani B,et al. Clinical dose-volume histogram analysis for pneumonitis after 3D treatment for non-small cell lung cancer[J].Int J Radiat Oncol Biol Phys, 1999,45:323-329.
  • 10Tai P,van Dyk J,Yu E,et al.Variability of target volume delineation in cervical esophageal cancer [J]. Int J Radiat Oncol Biol Phys, 1998,42: 277-288.

共引文献78

同被引文献116

引证文献17

二级引证文献88

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部