单、双、三螺纹种植体初期稳定性的三维有限元比较研究 被引量:8

Comparative study of primary stability of immediate loading of single-threaded, double-threaded and triple-threaded implants based on a three-dimensional finite element analysis
在线阅读 下载PDF
导出
摘要 目的:使用三维有限元的方法分析单、双、三螺纹种植体即刻负载时的稳定性的情况,对这3种螺纹进行综合评价。方法:利用Pro/E软件、Hypermesh软件及ABAQUS有限元软件,建立3类种植体即刻负载的三维有限元模型,比较3种螺纹在分别垂直和水平加载时对种植体初期稳定性的影响。结果:3种螺纹形态中,单螺纹的垂直相对位移和综合相对位移最小,三螺纹最大。结论:随着种植体旋转角度的增加,其对抗垂直载荷的抵抗力减弱。 Objective: To compare primary stability of three types of implants based on a three-dimensional finite element analysis. Methods: Using the commercial code of Pro/E software, Hypermesh software, and ABAQUS software to create 3-dimensional finite element models. The micromotions of the finite element models were computed with the ABAQUS software. Results: Vertical and resultant relative displacement of double-threaded implant was the smallest in the three types of implants. Conclusion: Single-threaded implant has the best capability of resisting vertical relative displacement. Triple-threaded implant has the best capability of resisting horizontal relative displacement. Under the circumstance that the vertical relative displacement is dominating, whenever horizontal loading or vertical loading, the resultant relative displacement of single-threaded implant is the smallest.
出处 《口腔颌面修复学杂志》 2007年第4期281-283,共3页 Chinese Journal of Prosthodontics
关键词 种植 螺纹型牙种植体 三维有限元 初期稳定性 implant screw dental implant three-dimensional finite element primary stability
  • 相关文献

参考文献9

  • 1Nikellis I, Levi A, Nicolopoulos C. Immediate loading of 190 endosseous dental implants: a prospective observational study of 40 patient treatments with up to 2-year data[J]. Int J Oral Maxillofac Implants, 2004, 19(1 ): 116-123.
  • 2Roberts WE, Smith RK, Zilberman Y, et al. Osseous adaptation to continuous loading of rigid endosseous implants [J].Am J Orthod, 1984, 86(2): 95-111.
  • 3Steigenga JT, al-Shammari KF, Nociti FH, et al. Dental implant design and its relationship to long-term implant success[J]. Implant Dent, 2003, 12(4): 306-317.
  • 4Tanaka E, Hanaoka K, Tanaka M, et al. Viscoelastic properties of bovine retrodiscal tissue under tensile stress-relaxation[J]. Eur J Oral, Sci.2003, 111(6): 518-522.
  • 5Yetkinler DN, Litsky AS. Viscoelastic behaviour of acrylic bonecements[J]. Biomaterials, 1998, 19(17): 1551-1559.
  • 6Kitamura E, Stegaroiu R, Nomura S, et al. Biomechanical aspects of marginal bone resorption around osseointegrated implantsconsiderations based on a three-dimensional finite element analysis[J]. Clin Oral Implants Res. 2004, 15 (4): 401-412.
  • 7Akca K, Iplikcioglu H. Finite element stress analysis of the influence of staggered versus straight placement of dental implants[J]. Int J Oral Maxillofac Implants, 2001, 16 (5): 722-730.
  • 8Mellal A, Wiskott HW, Botsis J, et al. Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data [J]. Clin Oral Implants Res, 2004, 15(2):239-248.
  • 9马攀,刘洪臣,李德华,林升,彭勤建,史真,吴晓霞.三种螺距对种植体初期稳定性影响的有限元研究[J].口腔颌面修复学杂志,2007,8(1):47-49. 被引量:20

二级参考文献12

  • 1马攀,李德华,宋应亮,李皓萍,孔亮,刘宝林,黄达文,姜惠娟.Pro/E的自适应功能在建立螺纹型牙种植体骨块三维有限元模型中的应用[J].口腔医学研究,2005,21(6):622-624. 被引量:6
  • 2Sul Y T, Johansson C B, Jeong Y, et al. Resonance frequency and removal torque analysis of implants with turned and anodized surface oxides [J]. Clinical Oral Implants Research, 2002,13: 252-259
  • 3Skalak R. Biomechanical considerations in osseointegrated prostheses[J]. J Prosthet Dent, 1983, 49(6):843-848
  • 4Scacchi M. The development of the ITI DENTAL IMPLANT SYSTEM. Part1: A review of the literature [J]. Clin Oral Implants Res, 2000, 11 Suppl : 18-21
  • 5Nociti FH Jr, Machado MA, Stefani CM, et al. Absorbable versus nonabsorbable membranes and bone grafts in the treatment of ligature-induced peri-implantitis defects in dogs: a histometric investigation [J]. Int J Oral Maxillofac Implants, 2001 , 16(5):646-652
  • 6Sennerby L, Wennerberg A, Pasop F. A new microtomographic technique for non-invasive evaluation of the bone structure around implants [J]. Clin Oral Implants Res,2001,12(1):91-94
  • 7Akkocaoglu M, Uysal S, Tekdemir I, et al. Implant design and intraosseous stability of immediately placed implants: a human cadaver study[J]. Clin Oral Implants Res, 2005, 16(2):202-219
  • 8Mellal A, Wiskott HW, Botsis J, et al. Stimulating effect of implant loading on surrounding bone. Comparison of three numerical models and validation by in vivo data[J]. Clin Oral Implants Res, 2004, 15(2):239-248
  • 9E kitamu ra, r ste garoiu, s. Influence of marginal bone resorption on stress around an implant-a three-dimensional finite element analysis [J]. Journal of Oral Rehabilitation,2005, 32:279-286
  • 10Steigenga JT, al-Shammari KF, Nociti FH, et al. Dental implant design and its relationship to long-term implant success[J]. Implant Dent, 2003, 12 (4):305-317

共引文献19

同被引文献88

引证文献8

二级引证文献36

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部