摘要 目的探索一种可行的建立包含真实螺纹形态的牙种植体即刻负载三维有限元模型的方法,为牙种植体即刻负载相关研究提供模型支持。方法采用三维机械设计软件SolidW orks在计算机上建立螺纹型牙种植体、局部下颌骨块三维实体模型,将实体模型导入ABAQUS有限元软件,采用过盈配合法模拟实现即刻负载种植体骨界面初始应力,定义界面摩擦系数。结果在计算机上建立了真实螺纹形态牙种植体、下颌骨块的三维立体即刻负载有限元模型,随着过盈量的增加,界面初始应力相应逐渐增加。结论采用过盈配合法可模拟即刻负载种植体骨界面的初始应力状态,所建即刻负载有限元模型为牙种植体即刻负载研究打下了基础。 Objective To create 3-D models of immediately loaded screw-type dental implants for finite element analysis by computer. Methods Using the commercial code of SolidWorks, 3-D models of screw-type dental implants and a segment of mandibular bone were generated. By ABAQUS software, the 3-D implant-bone complex was meshed. The interfacial contact of bone and the implants was defined to be a frictional contact with the initial press-fit stress (by Interference Fit Option) to simulate the contact of immediately loaded implants and bone tissue. Results The finite element models of the immediately loaded screw-type implant were successfully created on the computer. As the interference fit got deeper, the interfacial initial press-fit stress got higher values. Conclusion The finite element models of the immediately loaded screw-type implants can be built with this method. The interfacial status of the primary press-fit stress can be simulated by the Interference Fit Options in the finite element software.
出处 《第三军医大学学报》 CAS CSCD 北大核心 2006年第11期1246-1248,共3页 Journal of Third Military Medical University
关键词 螺纹型牙种植体 三维有限元 过盈配合 screw type dental implants three dimensional finite element analysis interference fit
  • 相关文献

参考文献9

  • 1HIMMLOVA L,DOSTALOVA T,KACOVSKY A,et al.Influence of implant length and diameter on stress distribution:a finite element analysis[J].J Prosthet Dent,2004,91(1):20-25.
  • 2HUJA S S,QIAN H,ROBERTS W E,et al.Effects of callus and bonding on strains in bone surrounding an implant under bending[J].Int J Oral Maxillofac Implants,1998,13(5):630-638.
  • 3PIERRISNARD L,HURE G,BARQUINS M,et al.Two dental implants designed for immediate loading:a finite element analysis[J].Int J Oral Maxillofac Implants,2002,17(3):353-362.
  • 4HUANG H M,LEE S Y,YEH C Y,et al.Resonance frequency assessment of dental implant stability with various bone qualities:a numerical approach[J].Clin Oral Implants Res,2002,13(1):65-74.
  • 5MELLAL A,WISKOTT H W,BOTSIS J,et al.Stimulating effect of implant loading on surrounding bone.Comparison of three numerical models and validation by in vivo data[J].Clin Oral Implants Res,2004,15(2):239-248.
  • 6MEREDITH N,BOOK K,FRIBERG B,et al.Resonance frequency measurements of implant stability in vivo.A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla[J].Clin Oral Implants Res,1997,8(3):226-233.
  • 7GAPSKI R,WANG H L,MASCARENHAS P,et al.Critical review of immediate implant loading[J].Clin Oral Implants Res,2003,14(5):515-527.
  • 8PAPAVASILIOU G,KAMPOSIORA P,BAYNE S C,et al.Three-dimensional finite element analysis of stress-distribution around single tooth implants as a function of bony support,prosthesis type,and loading during function[J].J Prosthet Dent,1996,76(6):633-640.
  • 9STEIGENGA J T,AL-SHAMMARI K F,NOCITI F H,et al.Dental implant design and its relationship to long-term implant success[J].Implant Dent,2003,12(4):306-317.