PVP/CdS量子点修饰电极的制备及其对肌红蛋白的直接电化学研究 被引量:1

Preparation of PVP/CdS quantum dots modified electrode and its application in electroanalysis of myoglobin
在线阅读 下载PDF
导出
摘要 该文采用溶胶-凝胶法制备了聚乙烯吡咯烷酮(PVP)表面修饰的硫化镉(Cds)半导体量子点,用透射电镜(TEM)、X 射线衍射(XRD)等手段进行了表征;将其修饰在玻碳电极(GC)表面制得量子点修饰电极,并研究了肌红蛋白(Myoglobin,Mb)在该量子点修饰电极上的电化学行为。实验结果表明,PVP/CdS 量子点修饰电极对肌红蛋白具有催化还原作用,且还原峰电流与被测蛋白质浓度呈良好线性关系。流动注射分析结果进一步表明该量子点修饰电极具有高的稳定性和好的重现性,检出限为2.0×10^(-9)mol/L,该电极可作为检测肌红蛋白的新型高灵敏度电化学传感器。 In this paper, poly (N - vinyl - 2 - pyrrolidone) (PVP) - capped CdS quantum dots (QDs) were synthesized by a sol - gel method from CdCl2 and Na2S in aqueous solution. The characteristics of the QDs composites were studied by transmission electron microscopy (TEM), X -ray diffraction (XRD) . For the first time, the resulting PVP - capped CdS QDs were modified onto the surface of glassy carbon electrode (GCE) to fabricated PVP - capped CdS QDs CME. The QDs were proved to have good biocompatibility to proteins. The electrochemical behaviors of myoglobin (Mb), on this QDs CME have been investigated. Novel reduction responses were observed for Mb on the CME in aqueous solutions, which could not be found on bare GCE. In addition, the results of flow injection analysis (FIA) further suggested the high stability and reproducibility of the PVP - capped CdS QDs CME with a rather low determination limitation of 2. 0×10^-9 mol/L. The as - preparation CME could be utilized as a newly and sensitive sensor to myoglobin.
出处 《化学传感器》 CAS 2005年第2期51-56,共6页 Chemical Sensors
基金 国家自然科学基金(No.20175006) 高校博士点基金(No.20030269014)资助项目
  • 相关文献

参考文献13

二级参考文献69

  • 1Wasinger V C, Cordwell S J, Cerpa-Poljak A, et al. Progress with gene-product mapping of the mollicutes: Mycoplasma genitalium. Eleetrophoresis, 1995, 16(7): 1090-1094.
  • 2Aebersold R. CoasteUafions in a cellular universe. Nature, 2003,422:115-116.
  • 3Collins F S, Green E D, Guttmacher A E, et al. A vision of the future of geaomics research. Nature, 2003, 422: 835-847.
  • 4Patterson S D. Data analysis-the Achilles heel of proteomies.Nature Bioteehnology, 2003, 21:221-222.
  • 5Aebersold R, Mann M. Mass spectrometry-based proteomics.Nature, 2003, 422:198-207.
  • 6Hutches T,Yip T. New desorption strategies for the mass spectrometric analysis of macroraolecules. Rapid Commun Mass Speetrom, 1993, 7:576-580.
  • 7Chakravarti D N, Chakravarti B, Moutsatsos 1. Infonnatic tools for proteome profiling. Computational Proteomics, 2002, Suppl 32:S4-S15.
  • 8Ouellette J.Bioinfonnaties moves into the mainstream. The Industrial Physicist, 2003, 9(6) : 14-18.
  • 9Yip T T C, Chart J W M, Cho W C S, et al. Protein chip array profrling analysis in SARS patients identified serum amyloid A protein as biomarker potentially useful in monitoring the extent of pneumonia. Clinical Oaemistry, ( in press ) 2005, 51 (1) :45- 55.
  • 10Wu W, Hu W, Kavanagh J J. Proteomies in cancer research.International Journal of Gynecological Cancer, 2002, 12(5): 409.