摘要
为了减少水电站引水系统投资,提高引水系统运行可靠度,根据管坡和调压井地形、地质情况,选择混合引水方案和全洞引水方案进行比较,最后推荐全洞引水方案。全洞引水方案既避开不利地质,又节省投资,同时增加电能。
For reducing the investment in the water-intake system of hydroelectric stations,and guaranteeing the reliability of that system,also according to the gradient of pipes,the terrain of pressure-regulating wells,and the geologic situation,finally the whole-hole water-intake scheme should be recommended by comparing with mixed water-intake one.The whole-hole water-intake scheme has some advantages,such as avoiding bad geology,reducing investment,and increasing the volume of electricity.
出处
《闽西职业大学学报》
2004年第3期112-113,共2页
Journal of Minxi Vocational College