In Vitro Validation of Tissue Doppler Left Ventricular Regional Wall Velocities by Using a Novel Balloon Phantom 被引量:1

In Vitro Validation of Tissue Doppler Left Ventricular Regional Wall Velocities by Using a Novel Balloon Phantom
在线阅读 下载PDF
导出
摘要 To investigate the validity and accuracy of tissue Doppler imaging (TDI) using a novel balloon phantom, validation of TDI myocardial velocity measurements has been carried out indirectly from conventional M mode images. However it is not a true and independent gold standard. We described a new TDI validation method by using a specially developed left ventricular balloon model mounted in a water bath and constructed using two pear shaped balloons. It was connected to a pulsatile flow pump at 8 stroke volumes (50-85 ml/beat). The displacement and velocity of the balloon walls were recorded simultaneously by video imaging and TDI on a GE Vingmed System Five with a 5 MHz phased array probe at the highest frame rates available. Conventional M mode and 2 D imaging verified that our balloon model mimicked the shape and wall motion of left ventricle. There was a good correlation and agreement between the maximum video excursion of the anterior and posterior walls of the phantom and the results of the temporal integration of digital distance data by TDI (Anterior wall: r =0.97, SEE=0.24 mm, ±s =0.04±0.24 mm; Posterior wall: r =0.95, SEE=0.22 mm, ±s =0.03±0.24 mm). Analysis of the velocity profile by the TDI method showed that the velocity at each measured point was correlated well with the velocity obtained from the video images (Anterior wall: r =0.97, SEE=0.30 mm, ±s =-0.04±0.28 mm; Posterior wall: r =0.97, SEE=0.30 mm, ±s =0.04±0.28 mm). Our balloon model provided a new independent method for the validation of TDI data. This study demonstrated that the present TDI system is reliable for measuring wall motion distance and velocity. To investigate the validity and accuracy of tissue Doppler imaging (TDI) using a novel balloon phantom, validation of TDI myocardial velocity measurements has been carried out indirectly from conventional M mode images. However it is not a true and independent gold standard. We described a new TDI validation method by using a specially developed left ventricular balloon model mounted in a water bath and constructed using two pear shaped balloons. It was connected to a pulsatile flow pump at 8 stroke volumes (50-85 ml/beat). The displacement and velocity of the balloon walls were recorded simultaneously by video imaging and TDI on a GE Vingmed System Five with a 5 MHz phased array probe at the highest frame rates available. Conventional M mode and 2 D imaging verified that our balloon model mimicked the shape and wall motion of left ventricle. There was a good correlation and agreement between the maximum video excursion of the anterior and posterior walls of the phantom and the results of the temporal integration of digital distance data by TDI (Anterior wall: r =0.97, SEE=0.24 mm, ±s =0.04±0.24 mm; Posterior wall: r =0.95, SEE=0.22 mm, ±s =0.03±0.24 mm). Analysis of the velocity profile by the TDI method showed that the velocity at each measured point was correlated well with the velocity obtained from the video images (Anterior wall: r =0.97, SEE=0.30 mm, ±s =-0.04±0.28 mm; Posterior wall: r =0.97, SEE=0.30 mm, ±s =0.04±0.28 mm). Our balloon model provided a new independent method for the validation of TDI data. This study demonstrated that the present TDI system is reliable for measuring wall motion distance and velocity.
作者 吴瑛 李小魁
出处 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2001年第4期337-340,共4页 华中科技大学学报(医学英德文版)
关键词 tissue Doppler imaging in vitro left ventricular regional velocity tissue Doppler imaging in vitro left ventricular regional velocity
  • 相关文献

参考文献10

  • 1Ohte N,Narita H,Hashimoto T et al.Evaluation of left ventricular early diastolic performance by color tissue Doppler imaging of the mitral annulus[].The American Journal of Cardiology.1998
  • 2Miyatake K,Yamagishi M,Tanaka N et al.New method for evaluating left ventricular wall motion by color-coded tissue Doppler imaging: In vitro and in vivo studies[].Journalism Assn of Community College.1995
  • 3Gorcsan J,Deswal A,Mankad S et al.Quantification of the myocardial response to low-dose dobutamine using tissue Doppler echocardiographic measures of velocity and velocity gradient[].The American Journal of Cardiology.1998
  • 4Uematsu M,Miyatake K,Tanaka N et al.Myocardial velocity gradient as a new indicator of regional left ventricular contraction: Detection by a two-dimensional tissue Doppler imaging technique[].Journalism Assn of Community College.1995
  • 5Oki T,Iuchi A,Tabata T et al.Left ventricular systolic wall motion velocities along the long and short axes measured by pulsed tissue Doppler imaging in patients with atrial fibrillation[].Journal of the American Society of Echocardiography.1999
  • 6Galiuto L,Ignone G,Demaria A N.Contraction and relaxation velocities of the normal left ventricle using pulsed-wave tissue Doppler echocardiography[].The American Journal of Cardiology.1998
  • 7Bartel T,Muller S,Schurger D et al.Quantitative tissue Doppler echocardiography in comparison with M-mode measurements in health probands[].Zeitschrift fur Kardiologie.1997
  • 8McDicken W N,Sutherland G R,Moran C M et al.Color Doppler velocity imaging of the myocardium[].Ultrasound in Medicine and Biology.1992
  • 9Nagueh S F,Mikati I,Kopelen H A et al.Doppler estimation of left ventricular filling pressure in sinus tachycardia.A new application of tissue Doppler imaging[].Circulation.1998
  • 10Bland J M,Altman D G.Statistical methods for assessing agreement between two methods of clinical measurement[].The Lancet.1986