Intercomparison of Environmental Gamma doses Measured with A NaI(Tl) Survey Meter and Thermoluminescent Dosimeters(TLDs) in the Poonch Division of Azad Kashmir, Pakistan
1
作者 Muhammad Rafique Kimberlee J Kearfott +6 位作者 Khalil Ahmad Jabeen Akhter Abdul Razzaq Khan Raja Azhar Saeed Saeed Ur Rahman Matiullah Muhammad Usman Rajput 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第12期969-972,共4页
This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a Nal (TI) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime c... This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a Nal (TI) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime cancer risk (ELCR), for the inhabitants of Poonch division of the Azad Kashmir, Pakistan. CaF2: Dy (TLD-200) card dosimeters were installed at height of 1 m from ground at fifteen different locations covering the entire Poonch division comprising of three districts. 展开更多
关键词 in the Poonch Division of Azad Kashmir Survey Meter and thermoluminescent dosimeters TL tlds NAI
在线阅读 下载PDF
Assessment of Occupational Radiation Exposure for Radiotherapy Healthcare Workers at Kenyatta National Hospital Using Thermoluminescence Dosimeter LiF:Mg,Ti
2
作者 Collins Omondi Margaret Chege Samson Omondi 《Journal of Geoscience and Environment Protection》 2024年第7期14-24,共11页
Kenyatta National Hospital (KNH) is the largest public referral hospital with a comprehensive cancer treatment facility in East and Central Africa. Occupational radiation monitoring is a significant technique for demo... Kenyatta National Hospital (KNH) is the largest public referral hospital with a comprehensive cancer treatment facility in East and Central Africa. Occupational radiation monitoring is a significant technique for demonstrating compliance of radiation regulatory limits. The objective of the study was to carry out assessment of occupational radiation exposure among radiotherapy personnel at KNH using thermoluminescence dosimeter, TLD. KNH staff were monitored using dosimeter type TLD-100 made of LiF:Mg,Ti, on monthly basis. The reader system used for analysis was Harshaw 8800. The measurement established the average monthly accumulated occupational personnel dose for KNH to be 0.21 mSv and 0.29 mSv for Hp (10) and Hp (0.07) respectively. The accumulated dose results were within the maximum acceptable dose of 1.67 mSv/month and 41.6 mSv/month for Hp (10) and Hp (0.07) respectively. The investigation results were higher than the acceptable public limit of 0.08 mSv/month. Moreover, incidences were noted where the fetus dose limit 0.42 was also exceeded. Evaluation of statistical dose exposure among doctors, nurses and radiographers’ measurement results were within ±0.02 mSv. The study established the average KNH occupational radiation exposure levels for both Hp (10) and Hp (0.07) were within the ICRU recommendation, validating radiation protection safe practice. Data analysis of healthcare workers did not indicate exposure trend biased to any healthcare profession. Hence radiation risk cut across all professional categories. It is recommended that Radiation Monitoring program be reviewed to include non-clinical staff who access the facility. Radiation reporting should not be limited to one facility, but reflect cases where workers are involved in multiple multiple jobs. 展开更多
关键词 Occupational Monitoring EXPOSURE Thermoluminescence dosimeter and Radiotherapy
在线阅读 下载PDF
TLD的测量技术及其质量控制 被引量:6
3
作者 侯雪莉 戴军 陈宝维 《核电子学与探测技术》 CAS CSCD 北大核心 2005年第6期772-777,共6页
介绍了TLD测量系统中的读出器、TL控测器、退火炉、冷却系统、刻度源和刻度方法诸方面的质量控制问题,同时介绍了一些人们在测量中容易忽略但又很重要的测量技术问题,如擦洗加热盘和滤光片,退火温度控制和退火时间的计时方法等,对从事TL... 介绍了TLD测量系统中的读出器、TL控测器、退火炉、冷却系统、刻度源和刻度方法诸方面的质量控制问题,同时介绍了一些人们在测量中容易忽略但又很重要的测量技术问题,如擦洗加热盘和滤光片,退火温度控制和退火时间的计时方法等,对从事TLD测量的工作人员会有一定的帮助。 展开更多
关键词 热释光剂量计(tld) 测量技术 质量控制 双轨制
在线阅读 下载PDF
MatriXX系统结合TLD测量电子线全身放疗射野剂量参数的研究 被引量:3
4
作者 张书旭 周凌宏 +2 位作者 陈光杰 沈国辉 林生趣 《中国医疗设备》 2009年第2期9-11,共3页
目的探讨二维空气电离室矩阵MatriXX系统与热释光剂量计(TLD)相结合,测量电子线全身放疗(ETBI)射野剂量参数的可行性。方法用MatriXX系统、固体水模块、仿真人体模型及TLD,测量ETBI射野的百分深度剂量曲线、单野输出剂量和6个不同角度... 目的探讨二维空气电离室矩阵MatriXX系统与热释光剂量计(TLD)相结合,测量电子线全身放疗(ETBI)射野剂量参数的可行性。方法用MatriXX系统、固体水模块、仿真人体模型及TLD,测量ETBI射野的百分深度剂量曲线、单野输出剂量和6个不同角度射野照射后的剂量累积因子。结果按照1mm递增测出了ETBI射野的百分深度剂量曲线及ETBI剂量计算所需要的各种校正因子。结论MatriXX系统与TLD相结合测量ETBI射野的剂量学参数非常简便、高效,是ETBI测量的理想工具。 展开更多
关键词 二维空气电离室矩阵 MatriXX 热释光剂量计 体模 电子线放疗
在线阅读 下载PDF
X射线诊断患者剂量的TLD质量控制 被引量:2
5
作者 欧向明 李明生 +1 位作者 袁继龙 程金生 《中国医学装备》 2021年第7期10-13,共4页
目的:对X射线诊断患者及受检者体表剂量(ESD)的热释光剂量计(TLD)测量进行质量控制,使其监测数据具有溯源性,并进一步提高监测数据的可比性和可靠性。方法:通过邮寄比对的方式,在国际原子能机构(IAEA)二级标准剂量学实验室对2020年全国... 目的:对X射线诊断患者及受检者体表剂量(ESD)的热释光剂量计(TLD)测量进行质量控制,使其监测数据具有溯源性,并进一步提高监测数据的可比性和可靠性。方法:通过邮寄比对的方式,在国际原子能机构(IAEA)二级标准剂量学实验室对2020年全国各省市遴选25家检测机构的TLD照射标准曲线和盲样,由各检测机构单独测读后上报结果,完成统一的评估和质量控制。结果:在25家检测机构中,有23家的TLD盲样检测剂量的结果偏差均<10%,另外2家的偏差>30%。结论:此次TLD测量质量控制比对方案设计合理,达到了预期目的,保证了接受X射线诊断的患者及受检者的ESD监测数据的可靠性。 展开更多
关键词 患者体表剂量(ESD) 热释光剂量计(tld) 比对 X射线诊断 质量控制
在线阅读 下载PDF
TLD-LiF热释光剂量计在冠状动脉血管内再狭窄剂量学的应用研究 被引量:2
6
作者 王建华 徐志勇 +2 位作者 张良安 戴光复 苑淑渝 《中国辐射卫生》 2004年第4期241-243,共3页
目的 研究粉末 ,3mm× 3mm× 0 4mmTLD方片 ,3mm× 3mm× 0 2mmTLD方片和 1mm× 1mm×1mmTLD方片 4种TLD -LiF剂量计在近距离放射治疗冠状动脉再狭窄时的应用特性。方法 用上述 4种剂量计测量32 P液体球囊 ... 目的 研究粉末 ,3mm× 3mm× 0 4mmTLD方片 ,3mm× 3mm× 0 2mmTLD方片和 1mm× 1mm×1mmTLD方片 4种TLD -LiF剂量计在近距离放射治疗冠状动脉再狭窄时的应用特性。方法 用上述 4种剂量计测量32 P液体球囊 (直径为 3mm ,长度为 2 0mm)和1 0 3Pd放射性支架 (直径为 2 0mm ,长度为 13mm)的表面剂量和径向剂量 ,并将测量结果与蒙特卡罗代码 (MCNP4B)的计算结果进行比较。结果 粉末和方片剂量计的测量结果有一定的差异 ,经过方片粉末修正因子修正后 ,3mm× 3mm× 0 2mmTLD方片的结果与粉末一致。结论  3mm× 3mm× 0 2mmTLD方片可以测量冠状动脉再狭窄近距离放射治疗的径向剂量和表面剂量分布。 展开更多
关键词 近距离放射治疗 表面剂量 冠状动脉再狭窄 血管内再狭窄 剂量学 热释光剂量计 放射性支架 tld 蒙特卡罗 ^32P
在线阅读 下载PDF
蒙特卡罗方法用于LiFTLD自屏蔽因子的模拟计算
7
作者 魏熙晔 雷家荣 +3 位作者 袁永刚 崔高显 赵林 赵敏智 《核技术》 EI CAS CSCD 北大核心 2007年第7期580-584,共5页
自屏蔽因子是用LiFTLD探测器高精度测量n-γ混合场的重要参数。本文采用MCNP程序对文献中给定尺寸、密度和6Li含量的LiFTLD的自屏蔽因子进行了计算,并与推导的自屏蔽公式、Horowitz等的计算结果进行了比较。同时,对计算结果还专门设计... 自屏蔽因子是用LiFTLD探测器高精度测量n-γ混合场的重要参数。本文采用MCNP程序对文献中给定尺寸、密度和6Li含量的LiFTLD的自屏蔽因子进行了计算,并与推导的自屏蔽公式、Horowitz等的计算结果进行了比较。同时,对计算结果还专门设计了实验进行验证,证实MCNP计算自屏蔽因子所采用的模型和方法是可靠的。对于文献中没有给出自屏蔽因子的现有的LiFTLD,通过选取合理的模型,用MCNP计算了它们的自屏蔽因子。该研究结果对于n-γ混合场区分测量以及TLD的LET效应的研究都具有重要意义。 展开更多
关键词 自屏蔽因子 中子注量 蒙特卡罗方法 热释光探测器
在线阅读 下载PDF
关于TLD-100样品热释光现象的几点讨论
8
作者 贾栓稳 杨百瑞 P.D.Townsend 《人工晶体学报》 EI CAS CSCD 北大核心 1998年第4期19-23,共5页
本文对TLD100(LiF∶Mg∶Ti)样品的三维热释光(TL)谱进行了测量和分析,观测到了经室温辐照的样品具有64℃、116℃、156℃、190℃、218℃的发光峰及若干个高温峰;其发射谱主要由2.67eV、2.... 本文对TLD100(LiF∶Mg∶Ti)样品的三维热释光(TL)谱进行了测量和分析,观测到了经室温辐照的样品具有64℃、116℃、156℃、190℃、218℃的发光峰及若干个高温峰;其发射谱主要由2.67eV、2.82eV、3.19eV及3.34eV等4个发光带组成。本文还对辐照后的样品进行了吸收光谱的测量。结合前人的报告。 展开更多
关键词 热释光 三维热释光谱 吸收光谱(LiF晶体)tld100晶体
在线阅读 下载PDF
TLD和仿真盆腔模型核查宫颈癌后装治疗三维剂量分布的研究 被引量:2
9
作者 张书旭 李文华 +1 位作者 徐海荣 林生趣 《中国辐射卫生》 北大核心 2005年第3期167-169,共3页
目的探讨用JR1152F型热释光剂量计(TLD)和仿真人体盆腔模型核查宫颈癌腔内后装治疗三维剂量分布的可行性。方法测定JR1152-F-型TLD(规格1mm×1mm×6mm)用于铱-192剂量测量的升温程序、剂量线性响应范围和重复性,并对TLD剂量计... 目的探讨用JR1152F型热释光剂量计(TLD)和仿真人体盆腔模型核查宫颈癌腔内后装治疗三维剂量分布的可行性。方法测定JR1152-F-型TLD(规格1mm×1mm×6mm)用于铱-192剂量测量的升温程序、剂量线性响应范围和重复性,并对TLD剂量计及热释光剂量仪(FJ427-A1)进行剂量刻度,仿真人体盆腔模型分成6段、每一层面关键器官上设置若干直径1mm、长6mm的测试孔,孔中放入直径1mm、长6mm小铅条,插入宫腔管施源器,模拟机下拍摄X光定位片,取出铅条,测试孔内放入TLD剂量计,用microSelectronHDR后装治疗计划系统(TPS)设计腔内放疗模拟计划,给予A点剂量200cGy次,计算出各测试点的理论值和重建精度,按计划进行腔内后装照射,用热释光剂量仪对受照后的TLD剂量计进行重复测量。结果TLD剂量计剂量线性范围在300cGy内,相关系数0.997,重复性好于±4%,A点、B点、F点、膀胱和直肠剂量参考点实测剂量与TPS计算值符合较好,误差分别在±3.60%、±0.9%、±7.8%、±7.1%、6.4%内。结论用JR1152-F型TLD和仿真人体盆腔模型核查宫颈癌腔内后装治疗三维剂量分布准确、可靠。 展开更多
关键词 宫颈肿瘤 放射疗法 近距离治疗 热释光剂量计
在线阅读 下载PDF
Studying of Common Factors Affecting Reading of Lithium Fluoride Thermo-Luminescence Dosimeter Crystal
10
作者 Mohammed A. Ali Omer Abdulrahman A. Alsayyari +3 位作者 Jumaa Y. Tamboul Rowida B. Ali Amira A. Ahmed Ahmed Abukonna 《Open Journal of Biophysics》 2017年第1期14-24,共11页
The aim of this study was to study the technical factors affecting the reading of TLD (LiF:Mg:Ti) for radiation dosimetry. The method adapted was an exposure of LiF:Mg:Ti crystal with?γ-ray with the following filters... The aim of this study was to study the technical factors affecting the reading of TLD (LiF:Mg:Ti) for radiation dosimetry. The method adapted was an exposure of LiF:Mg:Ti crystal with?γ-ray with the following filters (Hp 0.07 and Hp?10), before and after usage of filter Hp?(0.07), annealing, cooling by nitrogen flux and crystal morphology by scanning electron microscope. The collected data analyzed by EXCELL software showed that: TLD average count/second (C/s) with filter Hp?(10) was greater than that obtained with filter Hp?(0.07) with an amount of 1191 c/s?(19%). Also the analysis showed that: the average C/s without filter Hp?(0.07) was greater than that with filter by an amount of 994.5 C/s (16.4%), and there was proportional linear relationship;as the applied dose increased the TLD C/s increased significantly (R2?=?0.9) based on the equations: y = 885.1x???286.5 and y = 860.5x?+ 856.8 for filtered and without filtered beam respectively, where?x?refers to applied dose in mGy and?y?refers to C/s. Also the average C/s without nitrogen flux (cooling) was greater than with nitrogen count with an amount of 52.4 C/s (11%). The annealing (without filter) causes a reduction in dose by 82.2?μGy (19.2%), and in case of annealing with filter, the dose reduced by 66.7?μGy (21.9%) relative to annealing without filter. The morphology of TLD crystal shown by scanning electron microscope SEM was a darkening surface after irradiation. 展开更多
关键词 Radiation Effects dosimeter Factors THERMOLUMINESCENCE
在线阅读 下载PDF
IMPROVEMENT IN PREPARATION OF LiF TLD AND OPTIMIZATION OF MEASUREMENT PARAMETERS
11
作者 张建 郭勇 +3 位作者 王兴功 杨甲祥 朱云平 李成林 《Nuclear Science and Techniques》 SCIE CAS CSCD 1994年第3期170-173,共4页
The technological process for prepaxation of LiF TLD is reported. Sixteen types of TLD of LiF:Mg,Ti and LiF:Mg,Cu,P series are produced for dosimetry of X, γradiations and in neutron-γmixed radiation field. The meas... The technological process for prepaxation of LiF TLD is reported. Sixteen types of TLD of LiF:Mg,Ti and LiF:Mg,Cu,P series are produced for dosimetry of X, γradiations and in neutron-γmixed radiation field. The measurement parameters have been optimizationally selected by factors of parameter evaluation (P) and orthogonal method, and the procedure of quality control is recommended. 展开更多
关键词 thermoluminescent dosimeters LiF X-radiation Gamma radiation Quality assurance
在线阅读 下载PDF
THINDOWN IN LITHIUM FLUORIDE (TLD—100)
12
作者 罗达玲 Robert Katz 《Nuclear Science and Techniques》 SCIE CAS CSCD 1991年第3期147-152,共6页
A track structure model has been applied to calculate the relative thermoluminescent efficiency of TLD- 100 irradiated with energetic heavy ions. In earlier work we proposed that the response of TLD- 100 to γ-ray ari... A track structure model has been applied to calculate the relative thermoluminescent efficiency of TLD- 100 irradiated with energetic heavy ions. In earlier work we proposed that the response of TLD- 100 to γ-ray arises from a combination of 1- hit and 2- hit trap structures. The supralinear (2- hit) response is now known to diminish with a decrease in the energy of incident electrons. Since the delta rays of slow particles are of low energy, diminishing with a reduction in ion speed, we calculate the response to slow heavy ions by track theory as due to the 1- hit targets alone and obtain good agreement between theory and experiment. The branching of the experimental curves is principally caused by the kinematic limit in delta ray production for ions approaching the end of their range, an effect which is called "thidown" when seen in the tracks of heavy ions approaching the end of their range in electron sensitive nuclear emulsion. 展开更多
关键词 tld-100 Supralinear RESPONSE TRACK STRUCTURE RELATIVE thermoluminescent EFFICIENCY
在线阅读 下载PDF
实践八号育种卫星搭载植物种子的空间辐射剂量分析 被引量:27
13
作者 吕兑财 黄增信 +6 位作者 赵亚丽 郭会君 王根良 贾向红 李春华 张龙 刘录祥 《核农学报》 CAS CSCD 北大核心 2008年第1期5-8,共4页
为了探明植物种子在空间搭载后发生一系列改变的原因,尤其是探寻空间辐射与突变发生的内在关联,设计了"照相定位"实验法,采用CR-39固体核径迹探测器来探测空间重离子,并利用空间重离子径迹与植物种子的相对位置,来确定被重离... 为了探明植物种子在空间搭载后发生一系列改变的原因,尤其是探寻空间辐射与突变发生的内在关联,设计了"照相定位"实验法,采用CR-39固体核径迹探测器来探测空间重离子,并利用空间重离子径迹与植物种子的相对位置,来确定被重离子击中的种子及其击中部位;同时用LiF热释光片测量种子所受的较低LET空间辐射的剂量。结果表明,"照相定位"法简便易行,经济实用,并极大地缩短镜下分析时间;最终测得空间重离子注量率为4.44个/cm2.d,种子所受较低LET空间辐射的平均剂量为4.79mGy。 展开更多
关键词 实践八号卫星 空间辐射育种 植物种子 CR-39 核径迹 LiF热释光片 辐射剂量
在线阅读 下载PDF
油气藏地表热释光异常的研究 被引量:6
14
作者 郑公望 任秀生 +1 位作者 田昭舆 李英奎 《核电子学与探测技术》 CAS CSCD 北大核心 1999年第2期81-83,共3页
利用地表土的热释光异常区探寻地下油气藏,是一种新的尝试,并且已经取得了初步成效。研究表明,这种地表热释光异常区与地下油气藏相对应,它与地表物质的矿物组分或化学元素方面的差异无关。
关键词 油气勘查 热释光 剂量片 油气藏
在线阅读 下载PDF
鉴别式热释光个人剂量计的性能及参加国际比对的概况 被引量:6
15
作者 王其亮 郑善校 +1 位作者 胡爱英 王建超 《核电子学与探测技术》 CAS CSCD 北大核心 1999年第2期84-89,共6页
介绍了鉴别式热释光个人剂量计的性能。包括剂量计结构、实验方法、体模反散射、能量响应和角响应以及能量鉴别和剂量刻度。用此剂量计参加了由IAEA/RCA组织的个人剂量监测国际比对,在两个比对阶段中均获得了满意的结果。到目... 介绍了鉴别式热释光个人剂量计的性能。包括剂量计结构、实验方法、体模反散射、能量响应和角响应以及能量鉴别和剂量刻度。用此剂量计参加了由IAEA/RCA组织的个人剂量监测国际比对,在两个比对阶段中均获得了满意的结果。到目前为止,国内已有近50个个人剂量监测单位拥有该剂量计。 展开更多
关键词 鉴别式 个人剂量计 tld 国际比对 热释光
在线阅读 下载PDF
DPF脉冲X射线能谱测量 被引量:4
16
作者 郭红霞 龚建成 +7 位作者 何宝平 林东生 王文生 彭宏论 常冬梅 杨海帆 王永强 罗尹虹 《核技术》 EI CAS CSCD 北大核心 2000年第1期22-26,共5页
采用滤光法对DPF脉冲X射线源装置的X射线能谱进行了测量,取得了较好的结果,为辐射效应环境测量提供了一种手段。
关键词 DPF 滤光法 X射线能谱 热释光剂量片 辐照效应
在线阅读 下载PDF
乳腺癌螺旋断层放射治疗与调强放射治疗的剂量学研究与临床剂量实测比较 被引量:15
17
作者 沈奕晨 王为 +3 位作者 张松方 屠永清 查元梓 蒋马伟 《中国医学物理学杂志》 CSCD 2018年第3期269-274,共6页
目的:利用螺旋断层放射治疗技术与传统医用直线加速器对乳腺癌放疗中重要正常组织与靶区剂量-体积参数进行剂量学比较。同时,在剂量学研究基础上进行临床实际吸收剂量测量验证各种技术间临床应用的优势与劣势。方法:选取10例T_1N_0M_0... 目的:利用螺旋断层放射治疗技术与传统医用直线加速器对乳腺癌放疗中重要正常组织与靶区剂量-体积参数进行剂量学比较。同时,在剂量学研究基础上进行临床实际吸收剂量测量验证各种技术间临床应用的优势与劣势。方法:选取10例T_1N_0M_0期乳腺癌保乳术后行乳腺靶区放射治疗病人(无锁骨上照射区域),处方剂量为50 Gy/25次,利用螺旋断层放射治疗定角调强技术、螺旋断层放疗技术与医用直线加速器调强技术,比较乳腺癌靶区剂量和正常组织剂量的优劣。评估靶区剂量与适形度指数(CI)、均匀性指数(HI)和正常组织剂量-体积参数,进行剂量学比较。同时,利用热释光剂量仪在乳腺癌病人表皮进行实测剂量,比较3种技术处理由于病人呼吸运动对表面剂量的影响,及评估时间因素对治疗效率的影响。结果:10例乳腺癌病人采用定角调强技术、螺旋断层放疗技术与医用直线加速器调强技术PTV HI分别为0.15±0.01、0.06±0.01和0.20±0.15(P<0.001);CI分别为0.76±0.00、0.81±0.03和0.74±0.04(P>0.05);心脏平均剂量分别为4.12±0.87、3.82±0.53、6.33±2.49 Gy(P<0.001),左前降支最大剂量分别为20.38±5.66、13.34±3.78、34.56±4.12 Gy(P<0.001),患侧肺组织平均剂量分别为6.78±1.33、7.22±2.34、12.76±2.10 Gy(P<0.001)。患者6个实测剂量点的吸收剂量3种技术比较有统计学意义(P<0.001)。结论:从综合靶区覆盖、正常组织剂量-体积参数、剂量实测与治疗效率等方面比较,螺旋断层放射治疗的定角调强技术相对于其他两种技术而言有低剂量范围小、靶区覆盖佳、解决治疗中呼吸运动影响等优势,推荐使用该技术用于乳腺癌病人放射治疗。 展开更多
关键词 乳腺癌 螺旋断层放射治疗 调强放射治疗 定角调强技术 热释光剂量仪
在线阅读 下载PDF
热释光探测器在头部CT检查中监测晶状体器官的辐射剂量 被引量:4
18
作者 殷志杰 张显鹏 +2 位作者 李祥林 刘泉源 王静 《中国介入影像与治疗学》 CSCD 2014年第5期321-323,共3页
目的探讨应用热释光探测器(TLD)监测头部CT检查患者晶状体所接受的辐射剂量的价值。方法将TLD分别放置于仿真人模体右眼晶状体和左眼眼睑表面,应用常规扫描条件和高质量扫描条件进行头部CT扫描,比较不同位置和不同扫描条件下TLD所测辐... 目的探讨应用热释光探测器(TLD)监测头部CT检查患者晶状体所接受的辐射剂量的价值。方法将TLD分别放置于仿真人模体右眼晶状体和左眼眼睑表面,应用常规扫描条件和高质量扫描条件进行头部CT扫描,比较不同位置和不同扫描条件下TLD所测辐射剂量的差异。收集10例接受头部CT检查的患者,于左眼眼睑表面放置TLD,分析TLD对图像质量的影响。结果常规扫描条件下模体晶状体和眼睑表面TLD所测辐射剂量分别为(7.91±0.13)mGy和(8.02±0.09)mGy,差异无统计学意义(P>0.05),高质量扫描条件下模体晶状体和眼睑表面TLD所测辐射剂量分别为(12.68±0.25)mGy和(12.89±0.39)mGy,差异亦无统计学意义(P>0.05)。高质量扫描时晶状体和眼睑处TLD所测辐射剂量均高于常规扫描(P均<0.05)。10例接受头部扫描患者眼睑表面处TLD所测辐射剂量为(8.73±0.27)mGy;TLD所在层面图像左右眼玻璃体SNR分别为4.83±0.25和4.68±0.22(P>0.05)。结论头部CT检查中,在眼睑处放置TLD,对监测晶状体所接受辐射剂量具有一定价值。 展开更多
关键词 热释光探测器 晶状体 辐射剂量
在线阅读 下载PDF
热释光探测器在脉冲硬X射线能谱测量中的应用 被引量:6
19
作者 宋朝晖 王宝慧 +3 位作者 王奎录 黑东炜 孙凤荣 李刚 《核电子学与探测技术》 CAS CSCD 北大核心 2003年第1期46-49,共4页
介绍了TLD-3500热释光读出器和GR-100M型热释光剂量片构成的探测器在脉冲硬X射线辐射参数测量中的应用。详细论述了采用滤波荧光法与热释光探测器相结合测量10~100keV的硬X射线能谱的物理思想,在综合考虑了测量环境的具体情况下,设计... 介绍了TLD-3500热释光读出器和GR-100M型热释光剂量片构成的探测器在脉冲硬X射线辐射参数测量中的应用。详细论述了采用滤波荧光法与热释光探测器相结合测量10~100keV的硬X射线能谱的物理思想,在综合考虑了测量环境的具体情况下,设计研制了硬X射线测量系统,建立了热释光探测器对硬X射线绝对能量响应的标定方法。该方法已成功用于脉冲辐射装置"强光1号"的测量,并得到了实测数据。 展开更多
关键词 热释光探测器 滤波荧光法 脉冲X射线 能谱
在线阅读 下载PDF
放射性125I粒子植入患者术后24h周围人员及床边剂量检测及年累积剂量预测 被引量:7
20
作者 姜树坤 王俊杰 +3 位作者 闫先瑞 李永 杜明皓 王明清 《中国医学装备》 2020年第3期14-18,共5页
目的:探讨125I粒子植入患者术后24 h陪护、邻床患者和床边剂量检测及其年累积剂量预测。方法:选取29例行125I粒子植入术患者的陪护、邻床患者及患者床边,采用热释光剂量片贴于患者陪护和邻床患者甲状腺、左右晶体和左右性腺以及患床左... 目的:探讨125I粒子植入患者术后24 h陪护、邻床患者和床边剂量检测及其年累积剂量预测。方法:选取29例行125I粒子植入术患者的陪护、邻床患者及患者床边,采用热释光剂量片贴于患者陪护和邻床患者甲状腺、左右晶体和左右性腺以及患床左右侧中点处及左侧邻床左右中点处,于患者植入125I粒子24 h后对其进行剂量测量,经过计算得出其年累积剂量。结果:在应用防护用具的情况下125I粒子数、粒子活度及肿瘤中心至体表垂直距离的影响因素与受照射剂量无相关性。患者125I粒子植入术24 h后患者陪护的甲状腺、左右晶体和左右性腺的预计年累积剂量分别为0.31 mSv、0.23 mSv、0.26 mSv、0.33 mSv和0.33 mSv,邻床患者分别为0.11 mSv、0.22 mSv、0.27 mSv、0.13 mSv和0.32 mSv;患床左侧中点处和右侧中点处分别为1.03 mSv和0.95 mSv;邻床近侧中点处及远侧中点处分别为0.48 mSv及0.36 mSv;年累积剂量限值均未>1 mSv。结论:125I粒子术后患者在应用防护用具的情况下年累积剂量符合国家标准要求,对周围人群安全且无辐射影响。 展开更多
关键词 125I粒子植入 放射防护 热释光剂量计(tld) 受照射剂量 床边剂量