期刊文献+

Intercomparison of Environmental Gamma doses Measured with A NaI(Tl) Survey Meter and Thermoluminescent Dosimeters(TLDs) in the Poonch Division of Azad Kashmir, Pakistan

Intercomparison of Environmental Gamma doses Measured with A NaI(Tl) Survey Meter and Thermoluminescent Dosimeters(TLDs) in the Poonch Division of Azad Kashmir, Pakistan
在线阅读 下载PDF
导出
摘要 This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a Nal (TI) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime cancer risk (ELCR), for the inhabitants of Poonch division of the Azad Kashmir, Pakistan. CaF2: Dy (TLD-200) card dosimeters were installed at height of 1 m from ground at fifteen different locations covering the entire Poonch division comprising of three districts. This study presents the intercomparison of the outdoor environmental gamma dose rates measured using a Nal (TI) based survey meter along with thermoluminescent dosimeters (TLDs) and estimation of excess lifetime cancer risk (ELCR), for the inhabitants of Poonch division of the Azad Kashmir, Pakistan. CaF2: Dy (TLD-200) card dosimeters were installed at height of 1 m from ground at fifteen different locations covering the entire Poonch division comprising of three districts.
出处 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第12期969-972,共4页 生物医学与环境科学(英文版)
  • 相关文献

参考文献10

  • 1Simpkins RW, Kearfott KJ. The Minimum number of observations necessary to develop an average thermoluminescent dosimeter element correction factor.Radiat Prot Manag, 1997; 13, 55-61.
  • 2Harvey JA, Haverland NP, Kearfott KJ. Characterization of the glow peak fading properties of six common thermolumin- escent materials. App Radiat Isot, 2010; 68, 1988-2000.
  • 3Harvey JA, Kearfott KJ. Reproducibility of glow peak fading characteristics of thermoluminescent dosimeters. Radiat Meas, 2011; 46, 319-22.
  • 4Harvey JA, Kearfott KJ. Effects of high ambient temperature on glow-peak fading properties of LiF: Mg, Ti thermoluminescent dosemeters. Radiat Prot Dosim, 2012; 149, 109-15.
  • 5Harvey JA, Thomas EM, Kearfott KJ. Quantification of various factors influencing the accuracy and precision of thermoluminescent detector calibrations for new and used chip sets. Health Phys, 2011; 100,S79-S91.
  • 6Rafique M. Ambient indoor/outdoor gamma radiation dose rates in the city and at high altitudes of Muzaffarabad (Azact Kashmir). Environ Earth Sci, 2013; 70, 1783-90.
  • 7Rafique M, Basharat M, Azhar SR, et al. Effect of geology and altitude on ambient outdoor gamma dose rates in district poonch, Azad Kashmir. Carpath J Earth Env, 2013; 8, 165-73.
  • 8UNSCEAR. Ionizing radiation: Sources and biological effects, report to the general assembly with scientific annexes, United Nations, New York, 2000.
  • 9Worldstat info, http://en.worldstat.info/Asia/Pakistan, [2014-03-17].
  • 10Recommendations of the ICRP. Annals of the ICRP, 1990, 21, Publication 60.