期刊文献+
共找到1,231篇文章
< 1 2 62 >
每页显示 20 50 100
A quantum-enhanced magnetometer using a single high-spin nucleus in silicon
1
作者 Tao Xin Ke Zhang Jun Li 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第9期110-115,共6页
Quantum enhanced metrology has the potential to go beyond the standard quantum limit and eventually to the ultimate Heisenberg bound.In particular,quantum probes prepared in nonclassical coherent states have recently ... Quantum enhanced metrology has the potential to go beyond the standard quantum limit and eventually to the ultimate Heisenberg bound.In particular,quantum probes prepared in nonclassical coherent states have recently been recognized as a useful resource for metrology.Hence,there has been considerable interest in constructing magnetic quantum sensors that combine high resolution and high sensitivity.Here,we explore a nanoscale magnetometer with quantum-enhanced sensitivity,based on 123Sb(I=7/2)nuclear spin doped in silicon,that takes advantage of techniques of spin-squeezing and coherent control.With the optimal squeezed initial state,the magnetic field sensitivity may be expected to approach 6 aT·Hz^(−1/2)·cm^(−3/2) and 603 nT·Hz^(−1/2) at the single-spin level.This magnetic sensor may provide a novel sensitive and high-resolution route to microscopic mapping of magnetic fields as well as other applications. 展开更多
关键词 quantum magnetometer silicon quantum qubit nuclear electrical resonance
在线阅读 下载PDF
Performance optimization of a SERF atomic magnetometer based on flat-top light beam
2
作者 袁子琪 唐钧剑 +1 位作者 林树东 翟跃阳 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第6期330-336,共7页
We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spinexchange relaxation-free(SERF) atomic magnetometers(AMs). We conduct experiments comparing the traditio... We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spinexchange relaxation-free(SERF) atomic magnetometers(AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped(FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz–30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers. 展开更多
关键词 atomic magnetometer(AM) spin-exchange relaxation-free(SERF) flat-top light beam performance optimization
在线阅读 下载PDF
Response optimization of a three-axis sensitive SERF magnetometer for closed-loop operation
3
作者 周原锐 孙永泽 +3 位作者 汪茜茜 秦佳男 张雪 王言章 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期291-297,共7页
Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of the... Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of these methods is greatly limited because the frequency of the modulation signal should be slow enough to ensure the validity of the quasi-steady-state solution.In this work,a new model to describe the response of the three-axis sensitive SERF AM with high modulation frequency is presented and verified.The response of alkali-atomic spin to high-frequency modulation field is further investigated by solving the Bloch equation in a modulation-frequency-dependence manner.This solution is well verified by our experiments and can offer a reference for selection of modulation frequencies.The result shows a potential to achieve a SERF AM operating in a geomagnetic field without heavy aluminum shielding when the modulation frequencies are selected properly. 展开更多
关键词 triaxial-vectorial magnetic field measurement spin-exchange relaxation free atomic magnetometer
在线阅读 下载PDF
SINS/DGPS/Magnetometer组合导航研究
4
作者 王直 张军 《航天控制》 CSCD 北大核心 2006年第3期21-24,34,共5页
本文针对SINS/DGPS/Magnetometer全组合系统进行了研究,建立了相应的误差模型和系统观测模型。应用扩展卡尔曼滤波算法将GPS测量方程和SINS动态线性化,进行SINS验前状态估计及其误差协方差时间更新。仿真结果表明:本文提出的组合导航系... 本文针对SINS/DGPS/Magnetometer全组合系统进行了研究,建立了相应的误差模型和系统观测模型。应用扩展卡尔曼滤波算法将GPS测量方程和SINS动态线性化,进行SINS验前状态估计及其误差协方差时间更新。仿真结果表明:本文提出的组合导航系统能够给出载体的高精度姿态信息,位置误差和速度误差也较小。 展开更多
关键词 惯性导航系统 全球卫星定位系统 磁力计 卡尔曼滤波 伪距 载波相位
在线阅读 下载PDF
Miniature quad-channel spin-exchange relaxation-free magnetometer for magnetoencephalography 被引量:9
5
作者 Jian-Jun Li Peng-Cheng Du +3 位作者 Ji-Qing Fu Xu-Tong Wang Qing Zhou Ru-Quan Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第4期145-149,共5页
A miniature quad-channel optically pumped atomic magnetometer(OPM) has been developed based on the spinexchange relaxation-free(SERF) mechanism. With a vapor cell of size 8 mm×8 mm×8 mm, we have incorporated... A miniature quad-channel optically pumped atomic magnetometer(OPM) has been developed based on the spinexchange relaxation-free(SERF) mechanism. With a vapor cell of size 8 mm×8 mm×8 mm, we have incorporated four SERF magnetometer channels, which provides sufficient spatial resolution for magnetoencephalography(MEG). The four channels share the same laser beam for the best cancellation of common mode noise due to laser fluctuations. With gradient measurement, the sensitivities of the four sensors are better than 6 fT/Hz^(1/2), which is also good enough for MEG measurement. The vapor cell is heated to 160℃ by a novel nonmagnetic current-heating structure. Our sensor with high spatial resolution and compact size is particularly suitable for MEG systems. 展开更多
关键词 multi-channel SPIN-EXCHANGE relaxation-free optically PUMPED atomic magnetometer magne-toencephalography
在线阅读 下载PDF
Observing the steady-state visual evoked potentials with a compact quad-channel spin exchange relaxation-free magnetometer 被引量:5
6
作者 Peng-Cheng Du Jian-Jun Li +4 位作者 Si-Jia Yang Xu-Tong Wang Yan Zhuo Fan Wang Ru-Quan Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第4期141-144,共4页
We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of ... We observed the steady-state visually evoked potential(SSVEP) from a healthy subject using a compact quad-channel potassium spin exchange relaxation-free(SERF) optically pumped magnetometer(OPM). To this end, 30 s of data were collected, and SSVEP-related magnetic responses with signal intensity ranging from 150 fT to 300 f T were observed for all four channels. The corresponding signal to noise ratio(SNR) was in the range of 3.5–5.5. We then used different channels to operate the sensor as a gradiometer. In the specific case of detecting SSVEP, we noticed that the short channel separation distance led to a strongly diminished gradiometer signal. Although not optimal for the case of SSVEP detection, this set-up can prove to be highly useful for other magnetoencephalography(MEG) paradigms that require good noise cancellation.Considering its compactness, low cost, and good performance, the K-SERF sensor has great potential for biomagnetic field measurements and brain-computer interfaces(BCI). 展开更多
关键词 optically pumped magnetometerS steady-state visually EVOKED potentials MAGNETOENCEPHALOGRAPHY
在线阅读 下载PDF
China Seismo-Electromagnetic Satellite search coil magnetometerdata and initial results 被引量:9
7
作者 Qiao Wang JianPing Huang +4 位作者 XueMin Zhang XuHui Shen ShiGeng Yuan Li Zeng JinBin Cao 《Earth and Planetary Physics》 2018年第6期462-468,共7页
Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the wavefo... Four levels of the data from the search coil magnetometer(SCM) onboard the China Seismo-Electromagnetic Satellite(CSES)are defined and described. The data in different levels all contain three components of the waveform and/or spectrum of the induced magnetic field around the orbit in the frequency range of 10 Hz to 20 kHz; these are divided into an ultra-low-frequency band(ULF,10–200 Hz), an extremely low frequency band(ELF, 200–2200 Hz), and a very low frequency band(VLF, 1.8–20 kHz). Examples of data products for Level-2, Level-3, and Level-4 are presented. The initial results obtained in the commission test phase demonstrated that the SCM was in a normal operational status and that the data are of high enough quality to reliably capture most space weather events related to low-frequency geomagnetic disturbances. 展开更多
关键词 search coil magnetometer CSES data description EARTHQUAKE
在线阅读 下载PDF
Spin dynamics of the potassium magnetometer in spin-exchange relaxation free regime 被引量:2
8
作者 伏吉庆 杜鹏程 +1 位作者 周庆 王如泉 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第1期436-439,共4页
The laser-pumped potassium spin-exchange relaxation free (SERF) magnetometer is the most sensitive detector of magnetic field and has many important applications. We present the experimental results of our potassium... The laser-pumped potassium spin-exchange relaxation free (SERF) magnetometer is the most sensitive detector of magnetic field and has many important applications. We present the experimental results of our potassium SERF magne- tometer. A pump-probe approach is used to identify the unique spin dynamics of the atomic ensemble in the SERF regime. A single channel sensitivity of 8 f.THz-1/2 is achieved with our SERF magnetometer. 展开更多
关键词 Larmor process spin-exchange relaxation free magnetometer atomic magnetometer
在线阅读 下载PDF
Transverse relaxation determination based on light polarization modulation for spin-exchange relaxation free atomic magnetometer 被引量:4
9
作者 Xue-Jing Liu Ming Ding +3 位作者 Yang Li Yan-Hui Hu Wei Jin Jian-Cheng Fang 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第7期276-280,共5页
A transverse relaxation determination of spin-exchange relaxation free (SERF) magnetometer based on polarization modulation technique is proposed. Compared with the radio-frequency (RF) excitation and light intens... A transverse relaxation determination of spin-exchange relaxation free (SERF) magnetometer based on polarization modulation technique is proposed. Compared with the radio-frequency (RF) excitation and light intensity excitation meth- ods used in SERF magnetometer, the light polarization modulation method has a high stability in low-frequency range, which indicates a more accurate transverse relaxation measurement. 展开更多
关键词 spin-exchange relaxation free (SERF) magnetometer LINEWIDTH optical polarization modulation
在线阅读 下载PDF
Chinese Antarctic Magnetometer Chain at the Cusp Latitude 被引量:2
10
作者 LIU Yonghua HU Hongqiao +14 位作者 YANG Huigen ZHANG Beichen SUN Bo WEI Fuhai LIU Yang LIU Jianjun WANG Rui CHEN Zhuotian HU Zejun HAN Desheng SHI Guitao HU Zhengyi WANG Tao AN Chunlei Mike Rose 《Advances in Polar Science》 2016年第2期102-106,共5页
A Chinese Antarctic Magnetometer (CAM) chain from Zhongshan Station (ZHS) to Dome-A (DMA) has been established since February 2009. A regular magnetometer is operated at ZHS, and four low power magnetometers are... A Chinese Antarctic Magnetometer (CAM) chain from Zhongshan Station (ZHS) to Dome-A (DMA) has been established since February 2009. A regular magnetometer is operated at ZHS, and four low power magnetometers are operated along the interior route from ZHS to DMA in the cusp latitude, extending over a distance of 1260 km. These stations fill an important void in the Antarctic magnetometer network. Furthermore, the CAM chain is magnetically conjugated with the Arctic region reaching from the Svalbard archipelago to Daneborg, on the east coast of Greenland. Conjugate measurements using the Arctic and Antarctic magnetometers provide excellent opportunities to investigate phenomena related to the coupling of the solar wind to the magnetosphere and ionosphere, such as magnetic impulse events, flux transfer events, traveling convection vortices and ultra-low frequency waves. 展开更多
关键词 magnetometerS magnetic perturbation cusp latitude CONJUGATE
在线阅读 下载PDF
Mars Orbiter magnetometer of China’s First Mars Mission Tianwen-1 被引量:10
11
作者 Kai Liu XinJun Hao +7 位作者 YiRen Li TieLong Zhang ZongHao Pan ManMing Chen XiaoWen Hu Xin Li ChengLong Shen YuMing Wang 《Earth and Planetary Physics》 CSCD 2020年第4期384-389,共6页
As one of the seven scientific payloads on board the Tianwen-1 orbiter,the Mars Orbiter Magnetometer(MOMAG)will measure the magnetic fields of and surrounding Mars to study its space environment and the interaction wi... As one of the seven scientific payloads on board the Tianwen-1 orbiter,the Mars Orbiter Magnetometer(MOMAG)will measure the magnetic fields of and surrounding Mars to study its space environment and the interaction with the solar wind.The instrument consists of two identical triaxial fluxgate magnetometer sensors,mounted on a 3.19 meter-long boom with a seperation of about 90 cm.The dual-magnetometers configuration will help eliminate the magnetic field interference generated by the spacecraft platform and payloads.The sensors are controlled by an electric box mounted inside the orbiter.Each magnetometer measures the ambient vector magnetic field over a wide dynamic range(to 10,000 nT per axis)with a resolution of 1.19 pT.Both magnetometers sample the ambient magnetic field at an intrinsic frequency of 128 Hz,but will operate in a model with alternating frequency between 1 and 32 Hz to meet telemetry allocations. 展开更多
关键词 MARS magnetic field magnetometer Tianwen-1 spaceflight instrumentation
在线阅读 下载PDF
High contrast atomic magnetometer based on coherent population trapping 被引量:2
12
作者 杨爱林 杨国卿 +1 位作者 徐云飞 林强 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第2期477-480,共4页
We present an experimental and theoretical investigation of the coherent population trapping (CPT) resonance excited on the D1 line of 87Rb atoms by bichromatic linearly polarized laser light. The experimental resul... We present an experimental and theoretical investigation of the coherent population trapping (CPT) resonance excited on the D1 line of 87Rb atoms by bichromatic linearly polarized laser light. The experimental results show that a lin||lin tran- sition scheme is a promising alternative to the conventional circular-circular transition scheme for an atomic magnetometer. Compared with the circular light transition scheme, linear light accounts for high-contrast transmission resonances, which makes this excitation scheme promising for high-sensitivity magnetometers. We also use linear light and circular light to detect changes of a standard magnetic field, separately. 展开更多
关键词 high contrast atomic magnetometer coherent population trapping
在线阅读 下载PDF
Low-T_c direct current superconducting quantum interference device magnetometer-based 36-channel magnetocardiography system in a magnetically shielded room 被引量:1
13
作者 邱阳 李华 +7 位作者 张树林 王永良 孔祥燕 张朝祥 张永升 徐小峰 杨康 谢晓明 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第7期590-594,共5页
We constructed a 36-channel magnetocardiography(MCG) system based on low-Tc direct current(DC) superconducting quantum interference device(SQUID) magnetometers operated inside a magnetically shielded room(MSR)... We constructed a 36-channel magnetocardiography(MCG) system based on low-Tc direct current(DC) superconducting quantum interference device(SQUID) magnetometers operated inside a magnetically shielded room(MSR). Weakly damped SQUID magnetometers with large Steward–Mc Cumber parameter βc(βc≈ 5), which could directly connect to the operational amplifier without any additional feedback circuit, were used to simplify the readout electronics. With a flux-to-voltage transfer coefficient V / Φ larger than 420 μV/Φ0, the SQUID magnetometers had a white noise level of about 5.5 f T·Hz-1/2when operated in MSR. 36 sensing magnetometers and 15 reference magnetometers were employed to realize software gradiometer configurations. The coverage area of the 36 sensing magnetometers is 210×210 mm2. MCG measurements with a high signal-to-noise ratio of 40 d B were done successfully using the developed system. 展开更多
关键词 superconducting quantum interference devices magnetometer MAGNETOCARDIOGRAPHY noise can-cellation
在线阅读 下载PDF
A Quaternion Scaled Unscented Kalman Estimator for Inertial Navigation States Determination Using INS/GPS/Magnetometer Fusion 被引量:4
14
作者 Wassim Khoder Bassem Jida 《Journal of Sensor Technology》 2014年第2期101-117,共17页
This Inertial Navigation System (INS), Global Positioning System (GPS) and fluxgate magnetometer technologies have been widely used in a variety of positioning and navigation applications. In this paper, a low cost so... This Inertial Navigation System (INS), Global Positioning System (GPS) and fluxgate magnetometer technologies have been widely used in a variety of positioning and navigation applications. In this paper, a low cost solid state INS/GPS/Magnetometer integrated navigation system has been developed that incorporates measurements from an Inertial Navigation System (INS), Global Positioning System (GPS) and fluxgate magnetometer (Mag.) to provide a reliable complete navigation solution at a high output rate. The body attitude estimates, especially the heading angle, are fundamental challenges in a navigation system. Therefore targeting accurate attitude estimation is considered a significant contribution to the overall navigation error. A better estimation of the body attitude estimates leads to more accurate position and velocity estimation. For that end, the aim of this research is to exploit the magnetometer and accelerometer data in the attitude estimation technique. In this paper, a Scaled Unscented Kalman Filter (SUKF) based on the quaternion concept is designed for the INS/GPS/Mag integrated navigation system under large attitude error conditions. Simulation and experimental results indicate a satisfactory performance of the newly developed model. 展开更多
关键词 INERTIAL Navigation System INERTIAL Sensor Model GPS magnetometer QUATERNION Attitude PARAMETERIZATION Rotation Vector Scaled AUGMENTED Unscented KALMAN Filter
在线阅读 下载PDF
A dual-axis, high-sensitivity atomic magnetometer 被引量:1
15
作者 李茹杰 全伟 +4 位作者 范文峰 邢力 王卓 翟跃阳 房建成 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第12期196-200,共5页
Atomic magnetometer (AM) operated in a spin-exchange relaxation-free (SERF) regime features superior sensitivity and non-cryogenic operation, and thus is competitive with the best superconducting quantum interfere... Atomic magnetometer (AM) operated in a spin-exchange relaxation-free (SERF) regime features superior sensitivity and non-cryogenic operation, and thus is competitive with the best superconducting quantum interference devices. Previously, SERF AM with fT/Hz1/2 level sensitivity commonly acted as a single-axis sensor. Here we demonstrate a dual-axis SERF AM capable of simultaneously and independently detecting x-and y-field components with a sensitivity of 20 fT/Hz1/2. As there is no necessity to worry about the cross-talk effects arising from field modulations, the dual-axis scheme proposed here is of particular interest to AM array and hence the biomagnetic applications. 展开更多
关键词 optically pumped magnetometers multi-axis field measurements high-sensitivity field measurements polarized atoms
在线阅读 下载PDF
All-Optical Cesium Atomic Magnetometer with High Sensitivity 被引量:2
16
作者 ZHANG Jun-Hai LIU Qiang +2 位作者 ZENG Xian-Jin LI Jiu-Xing SUN Wei-Min 《Chinese Physics Letters》 SCIE CAS CSCD 2012年第6期280-282,共3页
An all-optical cesium magnetometer with high sensitivity based on absorptive detection is reported.The experiment achieves a polarized rotational spectrum of the probe light which is induced by circular dichroism and ... An all-optical cesium magnetometer with high sensitivity based on absorptive detection is reported.The experiment achieves a polarized rotational spectrum of the probe light which is induced by circular dichroism and a quarter wave plate together.The frequency response of the rotational spectrum is 1.8mrad/Hz at Larmor precession resonance.Analyzing the signal-to-noise ratio from the experimentally observed spectrum,we predict that the magnetic measurement sensitivity of 0.3pT/Hz^(1/2) would be obtained in the responsive range from 20nT to 2000nT. 展开更多
关键词 SPECTRUM magnetometer POLARIZED
在线阅读 下载PDF
A laser pump-re-pump atomic magnetometer 被引量:2
17
作者 杨爱林 杨国卿 +2 位作者 蔡勋明 徐云飞 林强 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第12期177-181,共5页
We demonstrate experimentally an atomic magnetometer based on optical pumping theory, a magnetic resonance that is induced by a radio frequency field and dependent on the magnetic field strength. Compared with the con... We demonstrate experimentally an atomic magnetometer based on optical pumping theory, a magnetic resonance that is induced by a radio frequency field and dependent on the magnetic field strength. Compared with the conventional method using one radiation field, which is used not only as the probe beam but also as a pump beam, the additional re-pump beam can increase remarkably the amplitude of the signal. It is shown that the amplitude of the magnetic field resonance signal can increase more than 55% by using an additional re-pump beam, which makes the sensitivity of the magnetometer higher. Finally, we investigate the relation between amplitude of the signal and re-pump laser power, and calculate the atomic population in the trapping states with rate equations. 展开更多
关键词 atomic magnetometer optical pumping sensitivity
在线阅读 下载PDF
Automatic calculation of the magnetometer zero offset using the interplanetary magnetic field based on the Wang-Pan method 被引量:5
18
作者 XiaoWen Hu GuoQiang Wang ZongHao Pan 《Earth and Planetary Physics》 CSCD 2022年第1期52-60,共9页
The space-borne fluxgate magnetometer(FGM)requires regular in-flight calibration to obtain its zero offset.Recently,Wang GQ and Pan ZH(2021a)developed a new method for the zero offset calibration based on the properti... The space-borne fluxgate magnetometer(FGM)requires regular in-flight calibration to obtain its zero offset.Recently,Wang GQ and Pan ZH(2021a)developed a new method for the zero offset calibration based on the properties of Alfvén waves.They found that an optimal offset line(OOL)exists in the offset cube for a pure Alfvén wave and that the zero offset can be determined by the intersection of at least two nonparallel OOLs.Because no pure Alfvén waves exist in the interplanetary magnetic field,calculation of the zero offset relies on the selection of highly Alfvénic fluctuation events.Here,we propose an automatic procedure to find highly Alfvénic fluctuations in the solar wind and calculate the zero offset.This procedure includes three parts:(1)selecting potential Alfvénic fluctuation events,(2)obtaining the OOL,and(3)determining the zero offset.We tested our automatic procedure by applying it to the magnetic field data measured by the FGM onboard the Venus Express.The tests revealed that our automatic procedure was able to achieve results as good as those determined by the Davis-Smith method.One advantage of our procedure is that the selection criteria and the process for selecting the highly Alfvénic fluctuation events are simpler.Our automatic procedure could also be applied to find fluctuation events for the Davis-Smith method. 展开更多
关键词 fluxgate magnetometer in-flight calibration zero offset highly Alfvénic fluctuations automatic procedure
在线阅读 下载PDF
The Mars orbiter magnetometer of Tianwen-1:in-flight performance and first science results 被引量:2
19
作者 YuMing Wang TieLong Zhang +17 位作者 GuoQiang Wang SuDong Xiao ZhuXuan Zou Long Cheng ZongHao Pan Kai Liu XinJun Hao YiRen Li ManMing Chen ZhouBin Zhang Wei Yan ZhenPeng Su ZhiYong Wu ChengLong Shen YuTian Chi MengJiao Xu JingNan Guo Yang Du 《Earth and Planetary Physics》 EI CSCD 2023年第2期216-228,共13页
The Mars Orbiter MAGnetometer(MOMAG)is a scientific instrument onboard the orbiter of China’s first mission for Mars—Tianwen-1.Since November 13,2021,it has been recording magnetic field data from the solar wind to ... The Mars Orbiter MAGnetometer(MOMAG)is a scientific instrument onboard the orbiter of China’s first mission for Mars—Tianwen-1.Since November 13,2021,it has been recording magnetic field data from the solar wind to the magnetic pile-up region surrounding Mars.Here we present its in-flight performance and first science results,based on its first one and one-half months’data.Comparing these early MOMAG observations to the magnetic field data in the solar wind from NASA’s Mars Atmosphere and Volatile EvolutioN(MAVEN)mission,we report that the MOMAG magnetic field data are at the same level in magnitude,and describe the same magnetic structures with similar variations in three components.We recognize 158 clear bow shock(BS)crossings in these MOMAG data;their locations match well statistically with the modeled average BS.We also identify and compare five pairs of datasets collected when Tianwen-1’s orbiter and the MAVEN probe made simultaneous BS crossings.These BS crossings confirm the global shape of modeled BS,as well as the south-north asymmetry of the Martian BS.Two cases presented in this paper suggest that the BS is probably more dynamic at flank than near the nose.So far,MOMAG performs well,and provides accurate magnetic field vectors.MOMAG is continuously scanning the magnetic field surrounding Mars.Data from MOMAG’s measurements complement data from MAVEN and will undoubt edly advance our understanding of the plasma environment of Mars. 展开更多
关键词 MARS magnetic field Tianwen-1 magnetometer bow shock
在线阅读 下载PDF
Coherent population trapping magnetometer by differential detecting magneto–optic rotation effect 被引量:2
20
作者 张樊 田原 +1 位作者 张奕 顾思洪 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第9期355-358,共4页
A pocket coherent population trapping(CPT) atomic magnetometer scheme that uses a vertical cavity surface emitting laser as a light source is proposed and experimentally investigated.Using the differential detecting... A pocket coherent population trapping(CPT) atomic magnetometer scheme that uses a vertical cavity surface emitting laser as a light source is proposed and experimentally investigated.Using the differential detecting magneto–optic rotation effect,a CPT spectrum with the background canceled and a high signal-to-noise ratio is obtained.The experimental results reveal that the sensitivity of the proposed scheme can be improved by half an order,and the ability to detect weak magnetic fields is extended one-fold.Therefore,the proposed scheme is suited to realize a pocket-size CPT magnetometer. 展开更多
关键词 coherent population trapping atomic magnetometer magneto–optic rotation effect
在线阅读 下载PDF
上一页 1 2 62 下一页 到第
使用帮助 返回顶部