1 Introduction Early detection and diagnosis of stable coronary artery disease (SCAD) is essential for proactive secondary prevention of myocardial infarction (MI), control of disease progress, and reduction of mo...1 Introduction Early detection and diagnosis of stable coronary artery disease (SCAD) is essential for proactive secondary prevention of myocardial infarction (MI), control of disease progress, and reduction of mortality. Clinical decision-making in modem medicine is increasingly dependent on cardiovascular imaging techniques. 2012 ACCF/AHA/ACP/AATS/ PCNA/SCAI/STS guideline for the diagnosis and management of patients with stable ischemic heart disease has been issued by American Heart Association (AHA). European Society of Cardiology (ESC) has issued 2013 ESC guidelines on the management of stable coronary artery disease.展开更多
Objective To assess lumen visibility of coronary stents by 64-slice computed tomography (CT) coronary angiography, and determine the value of 64-slice CT in non-invasive detecting of in-stent restenosis after coro...Objective To assess lumen visibility of coronary stents by 64-slice computed tomography (CT) coronary angiography, and determine the value of 64-slice CT in non-invasive detecting of in-stent restenosis after coronary artery stent implantation. Methods Totally, 60 patients (54 males, aged 57.0±12.7 years) and /05 stents were investigated by 64-slice CT at a mean interval of 20.0±16.6 months after coronary stents implantation. Axial multi-planar reconstruction images of the stents and curved-planar reconstruction images through the median of the stents were reconstructed for evaluating stent image quality on a 5-point scale (1=excellent, 5=nonassessable), and stent lumen diameter was detected. Conventional coronary angiography was performed in 18 patients, and 32 stents were evaluated. Results Image quality was good to excellent on average (score 1.71±0.76). Stent image quality score was correlated to heart rate (r=0. 281, P〈0.01) and stent diameter (r=-0.480, P〈0.001). All the stents were assessable in lumen visibility with an average visible lumen diameter percentage of 60.7%±13.6%. Visible lumen diameter percentage was correlated to heart rate (r=-0.193, P〈0.05), stent diameter (r=0.403, P〈0.001), and stent image quality score (r=-0.500, P〈0.001). Visible lumen diameter percentage also varied depending on the stent type. In comparison with the conventional coronary angiography, 4 of 6 in-stent stenoses were correctly detected. The sensitivity and specificity for the detection of in-stent stenosis were 66.7% and 84.6%, respectively. Conclusions Using a 64-slice CT, the stent lumen is partly visible in most of the stents. And 64-slice CT may be useful in the assessment of stent patency.展开更多
Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiogr...Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients.Calcium scoring with plain scan images as well as multi-planar reconstruction(MPR),maximum intensity projection(MIP),and volume rendering technique(VRT) reconstruction with enhanced scan images were performed in all cases.The scan technique and post-reconstruction experience was summarized.The image quality was classified as 1 to 4 points,and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6±298.7(0-3 216.5).The average heart rate of the enhanced scan was 82.1±16.2(47-139) bpm.The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method,two or more phases supplemented method,and electrocardiogram editing method.Altogether 8 457 coronary segments were evaluated,among which 97.2% were evaluated as point 1,1.7% point 2,0.5% point 3,and 0.6% point 4.The coronary segments in 261 cases were completely normal,while 360 segments were diagnosed with <50% stenosis and 625 segments with ≥50% stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation.Heart rate is not a major source of the artifact,coronary segments can be well shown with single or multiple-phase reconstruction method.展开更多
Amyloidosis is a multisystem disease that is characterized by deposition of fibrils in extracellular tissue,which mainly involves the kidney,heart,and autonomic nervous system.Two types of amyloidosis typically infilt...Amyloidosis is a multisystem disease that is characterized by deposition of fibrils in extracellular tissue,which mainly involves the kidney,heart,and autonomic nervous system.Two types of amyloidosis typically infiltrate the heart,including immunoglobulin light-chain(AL)and amyloid transthyretin(ATTR).ATTR is further subdivided into wild-type ATTR and variant ATTR caused by point mutations in the TTR gene.[1]Wild-type ATTR is considered as not uncommon in older patients with heart failure.Recently,a comprehensive set of consensus recommendations for the suspicion and diagnosis of ATTR was published,with particular focus on the combined application of noninvasive methods.[2]We present here a case of wild-type TTR cardiac amyloidosis(ATTRwt-CA),which was diagnosed by noninvasive modalities,and provide an overview of the recommended diagnostic approach of CA.Furthermore,to the best of our knowledge,this is the first Chinese case of ATTRwt-CA reported to date.展开更多
In an attempt to overcome the limitations of titanium in dental and orthopaedic clinical applications, a new method has been developed to prepare calcium carbonate coatings on sandblasted and acid-etched (SA) titani...In an attempt to overcome the limitations of titanium in dental and orthopaedic clinical applications, a new method has been developed to prepare calcium carbonate coatings on sandblasted and acid-etched (SA) titanium implants. The purpose of this study was to investigate the effect of calcium carbonate-SA (CC-SA) implants on osseointegration in vivo. The surfaces of SA and CC-SA implants were characterised for surface morphology and surface chemistry. Subsequently, these two kinds of implants were implanted in the femoral condyles of rabbits. The implants were retrieved and prepared for histological and histomorphometric evaluation 1, 2, 4, 8 and 12 weeks after implantation. Significantly higher values of bone-to-implant contact of the entire implant except the gap area (BIC_ALL) and the bone-to-implant contact of the gap area (BIC_GAP) were found in animals with the CC-SA implants than in those with the SA implants at 4 weeks. Higher values of total gap bone were found in those with the CC-SA implants than in those with the SA implants at 1, 2 and 4 weeks. In conclusion, the current findings demonstrate that the calcium carbonate coating can improve and accelerate the early ingrowth of bone and osseointegration at the early healine phase. This may reduce clinical healinE times and thus improve implant success rates.展开更多
Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequen- tial scan mo...Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequen- tial scan mode compared with ECG-gated spiral scan mode in a population with atrial fibrillation. Methods Thirty-two patients with suspected coronary artery disease and permanent atrial fibrilla- tion referred for a second-generation 128-slice DSCT coronary angiography were included in the prospec- tive study. Of them, 17 patients (sequential group) were randomly selected to use a prospectively ECG.~triggered sequential scan, while the other 15 patients (spiral group) used a retrospectively ECG-gated spiral scan. The IQ was assessed by two readers independently, using a four-point grading scale from excel- lent (grade 1) to non-assessable (grade 4), based on the American Heart Association 15-segment model. IQ of each segment and effective dose of each natient were comDared between the two groups. Results The mean heart rate (HR) of the sequential group was 96±27 beats per minute (bpm) with a variation range of 73±25 bpm, while the mean HR of the spiral group was 86±22 bpm with a variationrange of 65±24 bpm. Both of the mean FIR (t= 1.91, P=0.243) and HR variation range (t=0.950, P=0.350) had no significant difference between the two groups. In per-segment analysis, IQ of the sequential group vs. spiral group was rated as excellent (grade 1) in 190/244 (78%) vs. 177/217 (82%) by readerl and 197/245 (80%) vs. 174/214 (81%) by reader2, as non-assessable (grade 4) in 4/244 (2%) vs. 2/217 (1%) by readerl and 6/245 (2%) vs. 4/214 (2%) by reader2. Overall averaged IQ per-patient in the sequential and spiral group showed equally good (1.27+0.19 vs. 1.25+0.22, Z=-0.834, P=0.404). The effective radiation dose of the sequential group reduced significantly compared with the spiral group (4.88±1.77 mSv vs. 10.20±3.64 mSv; t=-5.372, P=0.000). Conclusion Compared with retrospectively ECG-gated spiral scan, prospectively ECG-triggered sequential DSCT coronary angiography provides similarly diagnostically valuable images in patients with atrial fibrillation and significantly reduces radiation dose.展开更多
BACKGROUND Bone marrow mesenchymal stromal cells(BMSCs)are the commonly used seed cells in tissue engineering.Aryl hydrocarbon receptor(AhR)is a transcription factor involved in various cellular processes.However,the ...BACKGROUND Bone marrow mesenchymal stromal cells(BMSCs)are the commonly used seed cells in tissue engineering.Aryl hydrocarbon receptor(AhR)is a transcription factor involved in various cellular processes.However,the function of constitutive AhR in BMSCs remains unclear.AIM To investigate the role of AhR in the osteogenic and macrophage-modulating potential of mouse BMSCs(mBMSCs)and the underlying mechanism.METHODS Immunochemistry and immunofluorescent staining were used to observe the expression of AhR in mouse bone marrow tissue and mBMSCs.The overexpression or knockdown of AhR was achieved by lentivirus-mediated plasmid.The osteogenic potential was observed by alkaline phosphatase and alizarin red staining.The mRNA and protein levels of osteogenic markers were detected by quantitative polymerase chain reaction(qPCR)and western blot.After coculture with different mBMSCs,the cluster of differentiation(CD)86 and CD206 expressions levels in RAW 264.7 cells were analyzed by flow cytometry.To explore the underlying molecular mechanism,the interaction of AhR with signal transducer and activator of transcription 3(STAT3)was observed by co-immunoprecipitation and phosphorylation of STAT3 was detected by western blot.RESULTS AhR expressions in mouse bone marrow tissue and isolated mBMSCs were detected.AhR overexpression enhanced the osteogenic potential of mBMSCs while AhR knockdown suppressed it.The ratio of CD86+RAW 264.7 cells cocultured with AhR-overexpressed mBMSCs was reduced and that of CD206+cells was increased.AhR directly interacted with STAT3.AhR overexpression increased the phosphorylation of STAT3.After inhibition of STAT3 via stattic,the promotive effects of AhR overexpression on the osteogenic differentiation and macrophage-modulating were partially counteracted.CONCLUSION AhR plays a beneficial role in the regenerative potential of mBMSCs partially by increasing phosphorylation of STAT3.展开更多
Objective To explore the imaging and related clinical characteristics of magnetic resonance (MR) delayed enhancement in patients with ischemic or nonischemic heart disease. Methods Thirty-two cases who underwent MR...Objective To explore the imaging and related clinical characteristics of magnetic resonance (MR) delayed enhancement in patients with ischemic or nonischemic heart disease. Methods Thirty-two cases who underwent MR myocardial cine and delayed enhancement imaging from January 2004 to October 2006 were retrospectively analyzed. The cine sequence imaging included the four-chamber view and the left ventricular short axis view. The delayed enhancement imaging was taken 10 minutes after the infusion of gadolinium from the antecubital vein with a segmented inversion-recovery-prepared Tl-weighted fast gradient echo sequence. Patients underwent coronary computed tomography angiography (CTA) two weeks before or after the MR imaging examination. Combined with clinical history, the clinical and MR imaging characteristics of the patients who had delayed enhancement were analyzed. Results MR delayed enhancement could be found in 16 cases. Among them, 12 cases had ischemic heart disease. Their coronary CTA showed one to three vessel diseases. The delayed enhancement was transmural or subendocardium, and the area of delayed enhancement corresponded well with one or more coronary arteries which had severe stenosis or occlusion. Four cases had nonischemic heart diseases One case was dilated cardiomyopathy, with diffuse small midwall spots in delayed enhancemen and only 30% stenosis of the anterior descending coronary artery in coronary CTA. One case was hypertrophic cardiomyopathy, with delayed enhancement of strip- and patch-shaped at midwall of the hypertrophic myocardiurn. One case was restrictive cardiomyopathy, and the delayed enhancement was located in the area of subendocardium of both the right and left ventricles. Coronary CTA of these two cases were normal The other case was a mass of the lateral wall of the left ventricle, and the delayed enhancement with a clumpy shape was located in the lateral wall of the left ventricle. Conclusions MR myocardial delayed enhancement is not a specific sign of myocardial infarction of ischemic heart disease. Nonischemic heart diseases including all kinds of primary cardiomyopathy and some other diseases affecting myocardium can also cause delayed enhancement, but their characteristics are different. The differentiation of the etiology of the nonischemic heart disease with delayed enhancement relies upon the intimate connection with clinical history and the cine sequence MR images.展开更多
Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty pa...Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease.展开更多
A phosphine-catalyzed [4+3] annulation between dinucleophilic indole derivatives and Morita−Baylis−Hillman (MBH) carbonates was discovered by using the N1 and N4′/C4′ nucleophilicities of the indole precursors,in wh...A phosphine-catalyzed [4+3] annulation between dinucleophilic indole derivatives and Morita−Baylis−Hillman (MBH) carbonates was discovered by using the N1 and N4′/C4′ nucleophilicities of the indole precursors,in which indoles act as four atom synthons. This protocol provides an efficient and facile access to indole-1,2-fused 1,4-diazepinones and azepines in good to high yields in one step,which illustrates potential synthetic utilities in drug discovery.展开更多
Although iron oxide(Fe_(3)O_(4)) nanoparticles have broad application prospects as magnetic resonance imaging(MRI) contrast agent, their biocompatibility and biotoxicity still need to be improved. In this study, we pr...Although iron oxide(Fe_(3)O_(4)) nanoparticles have broad application prospects as magnetic resonance imaging(MRI) contrast agent, their biocompatibility and biotoxicity still need to be improved. In this study, we prepared Fe_(3)O_(4)@Angelica sinensis polysaccharide nanoparticles(Fe_(3)O_(4)@ASP NPs) with a 9 nm Fe_(3)O_(4) core and ASP as the coating material. The Fe_(3)O_(4)@ASP NPs are superparamagnetic, can be taken up by liver and spleen macrophages in the circulatory system in vivo, and are a good-biocompatibility and low-toxicity transverse relaxation time(T_(2)) and T_(2)-star(T_(2)^(*)) magnetic resonance imaging(MRI) contrast agent for the liver. The cytotoxicity assessment using HeLa cells and the pathological tests in mice validate that Fe_(3)O_(4)@ASP NPs have low toxicity and good biocompatibility in vivo, which can be attributed to the ASP as a natural polysaccharide with good biocompatibility and its function of protecting the liver. Fe_(3)O_(4)@ASP NPs are a potential new MRI contrast agent with high signal intensity in vivo.展开更多
Dear Editor Uveal melanoma(UM)is the most frequent primary malig-nant intraocular tumor in adults with an estimated inci-dence of 4-5 per million per year in western countries[1].About 50%of UM patients eventually dev...Dear Editor Uveal melanoma(UM)is the most frequent primary malig-nant intraocular tumor in adults with an estimated inci-dence of 4-5 per million per year in western countries[1].About 50%of UM patients eventually develop metas-tasis.In a previous study,the prognosis of Chinese UM was mainly correlated with visual clinical features and gene sequencing results.Models designed to predict UM prognosis have been previously described[2],but these studies were based on Caucasians,not Chinese.展开更多
文摘1 Introduction Early detection and diagnosis of stable coronary artery disease (SCAD) is essential for proactive secondary prevention of myocardial infarction (MI), control of disease progress, and reduction of mortality. Clinical decision-making in modem medicine is increasingly dependent on cardiovascular imaging techniques. 2012 ACCF/AHA/ACP/AATS/ PCNA/SCAI/STS guideline for the diagnosis and management of patients with stable ischemic heart disease has been issued by American Heart Association (AHA). European Society of Cardiology (ESC) has issued 2013 ESC guidelines on the management of stable coronary artery disease.
文摘Objective To assess lumen visibility of coronary stents by 64-slice computed tomography (CT) coronary angiography, and determine the value of 64-slice CT in non-invasive detecting of in-stent restenosis after coronary artery stent implantation. Methods Totally, 60 patients (54 males, aged 57.0±12.7 years) and /05 stents were investigated by 64-slice CT at a mean interval of 20.0±16.6 months after coronary stents implantation. Axial multi-planar reconstruction images of the stents and curved-planar reconstruction images through the median of the stents were reconstructed for evaluating stent image quality on a 5-point scale (1=excellent, 5=nonassessable), and stent lumen diameter was detected. Conventional coronary angiography was performed in 18 patients, and 32 stents were evaluated. Results Image quality was good to excellent on average (score 1.71±0.76). Stent image quality score was correlated to heart rate (r=0. 281, P〈0.01) and stent diameter (r=-0.480, P〈0.001). All the stents were assessable in lumen visibility with an average visible lumen diameter percentage of 60.7%±13.6%. Visible lumen diameter percentage was correlated to heart rate (r=-0.193, P〈0.05), stent diameter (r=0.403, P〈0.001), and stent image quality score (r=-0.500, P〈0.001). Visible lumen diameter percentage also varied depending on the stent type. In comparison with the conventional coronary angiography, 4 of 6 in-stent stenoses were correctly detected. The sensitivity and specificity for the detection of in-stent stenosis were 66.7% and 84.6%, respectively. Conclusions Using a 64-slice CT, the stent lumen is partly visible in most of the stents. And 64-slice CT may be useful in the assessment of stent patency.
文摘Objective To explore the scan technique and image quality of coronary angiography with dual source computed tomography(CT) without oral metoprolol preparation.Methods Plain and enhanced dual source CT coronary angiography without oral metoprolol preparation was prospectively performed in 600 patients.Calcium scoring with plain scan images as well as multi-planar reconstruction(MPR),maximum intensity projection(MIP),and volume rendering technique(VRT) reconstruction with enhanced scan images were performed in all cases.The scan technique and post-reconstruction experience was summarized.The image quality was classified as 1 to 4 points,and coronary segments classified according to the American Heart Association standards were evaluated.Results The average calcium score of the 600 cases was 213.6±298.7(0-3 216.5).The average heart rate of the enhanced scan was 82.1±16.2(47-139) bpm.The post-reconstruction methods with which coronary segments could be shown as best as possible consisted of single phase reconstruction method,two or more phases supplemented method,and electrocardiogram editing method.Altogether 8 457 coronary segments were evaluated,among which 97.2% were evaluated as point 1,1.7% point 2,0.5% point 3,and 0.6% point 4.The coronary segments in 261 cases were completely normal,while 360 segments were diagnosed with <50% stenosis and 625 segments with ≥50% stenosis.Conclusions Excellent coronary artery image can be obtained with dual source CT in patients with any heart rate without oral metoprolol preparation.Heart rate is not a major source of the artifact,coronary segments can be well shown with single or multiple-phase reconstruction method.
基金the National Key Research and Development Program of China(2016YFC0901500).
文摘Amyloidosis is a multisystem disease that is characterized by deposition of fibrils in extracellular tissue,which mainly involves the kidney,heart,and autonomic nervous system.Two types of amyloidosis typically infiltrate the heart,including immunoglobulin light-chain(AL)and amyloid transthyretin(ATTR).ATTR is further subdivided into wild-type ATTR and variant ATTR caused by point mutations in the TTR gene.[1]Wild-type ATTR is considered as not uncommon in older patients with heart failure.Recently,a comprehensive set of consensus recommendations for the suspicion and diagnosis of ATTR was published,with particular focus on the combined application of noninvasive methods.[2]We present here a case of wild-type TTR cardiac amyloidosis(ATTRwt-CA),which was diagnosed by noninvasive modalities,and provide an overview of the recommended diagnostic approach of CA.Furthermore,to the best of our knowledge,this is the first Chinese case of ATTRwt-CA reported to date.
基金funded by the National Natural Science Foundation of China(nos 81200812 and 81371170)the Foundation of Health and the family planning commission of Hubei province(no.WJ2015MB276)
文摘In an attempt to overcome the limitations of titanium in dental and orthopaedic clinical applications, a new method has been developed to prepare calcium carbonate coatings on sandblasted and acid-etched (SA) titanium implants. The purpose of this study was to investigate the effect of calcium carbonate-SA (CC-SA) implants on osseointegration in vivo. The surfaces of SA and CC-SA implants were characterised for surface morphology and surface chemistry. Subsequently, these two kinds of implants were implanted in the femoral condyles of rabbits. The implants were retrieved and prepared for histological and histomorphometric evaluation 1, 2, 4, 8 and 12 weeks after implantation. Significantly higher values of bone-to-implant contact of the entire implant except the gap area (BIC_ALL) and the bone-to-implant contact of the gap area (BIC_GAP) were found in animals with the CC-SA implants than in those with the SA implants at 4 weeks. Higher values of total gap bone were found in those with the CC-SA implants than in those with the SA implants at 1, 2 and 4 weeks. In conclusion, the current findings demonstrate that the calcium carbonate coating can improve and accelerate the early ingrowth of bone and osseointegration at the early healine phase. This may reduce clinical healinE times and thus improve implant success rates.
文摘Objective To evaluate the image quality (IQ) and radiation dose of 128-slice dual-source computed tomography (DSCT) coronary angiography using prospectively electrocardiogram (ECG)-triggered sequen- tial scan mode compared with ECG-gated spiral scan mode in a population with atrial fibrillation. Methods Thirty-two patients with suspected coronary artery disease and permanent atrial fibrilla- tion referred for a second-generation 128-slice DSCT coronary angiography were included in the prospec- tive study. Of them, 17 patients (sequential group) were randomly selected to use a prospectively ECG.~triggered sequential scan, while the other 15 patients (spiral group) used a retrospectively ECG-gated spiral scan. The IQ was assessed by two readers independently, using a four-point grading scale from excel- lent (grade 1) to non-assessable (grade 4), based on the American Heart Association 15-segment model. IQ of each segment and effective dose of each natient were comDared between the two groups. Results The mean heart rate (HR) of the sequential group was 96±27 beats per minute (bpm) with a variation range of 73±25 bpm, while the mean HR of the spiral group was 86±22 bpm with a variationrange of 65±24 bpm. Both of the mean FIR (t= 1.91, P=0.243) and HR variation range (t=0.950, P=0.350) had no significant difference between the two groups. In per-segment analysis, IQ of the sequential group vs. spiral group was rated as excellent (grade 1) in 190/244 (78%) vs. 177/217 (82%) by readerl and 197/245 (80%) vs. 174/214 (81%) by reader2, as non-assessable (grade 4) in 4/244 (2%) vs. 2/217 (1%) by readerl and 6/245 (2%) vs. 4/214 (2%) by reader2. Overall averaged IQ per-patient in the sequential and spiral group showed equally good (1.27+0.19 vs. 1.25+0.22, Z=-0.834, P=0.404). The effective radiation dose of the sequential group reduced significantly compared with the spiral group (4.88±1.77 mSv vs. 10.20±3.64 mSv; t=-5.372, P=0.000). Conclusion Compared with retrospectively ECG-gated spiral scan, prospectively ECG-triggered sequential DSCT coronary angiography provides similarly diagnostically valuable images in patients with atrial fibrillation and significantly reduces radiation dose.
基金Supported by National Natural Science Foundation of China,No.82001014,No.82071090Hubei Provincial Natural Science Foundation of China,No.2022CFB115.
文摘BACKGROUND Bone marrow mesenchymal stromal cells(BMSCs)are the commonly used seed cells in tissue engineering.Aryl hydrocarbon receptor(AhR)is a transcription factor involved in various cellular processes.However,the function of constitutive AhR in BMSCs remains unclear.AIM To investigate the role of AhR in the osteogenic and macrophage-modulating potential of mouse BMSCs(mBMSCs)and the underlying mechanism.METHODS Immunochemistry and immunofluorescent staining were used to observe the expression of AhR in mouse bone marrow tissue and mBMSCs.The overexpression or knockdown of AhR was achieved by lentivirus-mediated plasmid.The osteogenic potential was observed by alkaline phosphatase and alizarin red staining.The mRNA and protein levels of osteogenic markers were detected by quantitative polymerase chain reaction(qPCR)and western blot.After coculture with different mBMSCs,the cluster of differentiation(CD)86 and CD206 expressions levels in RAW 264.7 cells were analyzed by flow cytometry.To explore the underlying molecular mechanism,the interaction of AhR with signal transducer and activator of transcription 3(STAT3)was observed by co-immunoprecipitation and phosphorylation of STAT3 was detected by western blot.RESULTS AhR expressions in mouse bone marrow tissue and isolated mBMSCs were detected.AhR overexpression enhanced the osteogenic potential of mBMSCs while AhR knockdown suppressed it.The ratio of CD86+RAW 264.7 cells cocultured with AhR-overexpressed mBMSCs was reduced and that of CD206+cells was increased.AhR directly interacted with STAT3.AhR overexpression increased the phosphorylation of STAT3.After inhibition of STAT3 via stattic,the promotive effects of AhR overexpression on the osteogenic differentiation and macrophage-modulating were partially counteracted.CONCLUSION AhR plays a beneficial role in the regenerative potential of mBMSCs partially by increasing phosphorylation of STAT3.
文摘Objective To explore the imaging and related clinical characteristics of magnetic resonance (MR) delayed enhancement in patients with ischemic or nonischemic heart disease. Methods Thirty-two cases who underwent MR myocardial cine and delayed enhancement imaging from January 2004 to October 2006 were retrospectively analyzed. The cine sequence imaging included the four-chamber view and the left ventricular short axis view. The delayed enhancement imaging was taken 10 minutes after the infusion of gadolinium from the antecubital vein with a segmented inversion-recovery-prepared Tl-weighted fast gradient echo sequence. Patients underwent coronary computed tomography angiography (CTA) two weeks before or after the MR imaging examination. Combined with clinical history, the clinical and MR imaging characteristics of the patients who had delayed enhancement were analyzed. Results MR delayed enhancement could be found in 16 cases. Among them, 12 cases had ischemic heart disease. Their coronary CTA showed one to three vessel diseases. The delayed enhancement was transmural or subendocardium, and the area of delayed enhancement corresponded well with one or more coronary arteries which had severe stenosis or occlusion. Four cases had nonischemic heart diseases One case was dilated cardiomyopathy, with diffuse small midwall spots in delayed enhancemen and only 30% stenosis of the anterior descending coronary artery in coronary CTA. One case was hypertrophic cardiomyopathy, with delayed enhancement of strip- and patch-shaped at midwall of the hypertrophic myocardiurn. One case was restrictive cardiomyopathy, and the delayed enhancement was located in the area of subendocardium of both the right and left ventricles. Coronary CTA of these two cases were normal The other case was a mass of the lateral wall of the left ventricle, and the delayed enhancement with a clumpy shape was located in the lateral wall of the left ventricle. Conclusions MR myocardial delayed enhancement is not a specific sign of myocardial infarction of ischemic heart disease. Nonischemic heart diseases including all kinds of primary cardiomyopathy and some other diseases affecting myocardium can also cause delayed enhancement, but their characteristics are different. The differentiation of the etiology of the nonischemic heart disease with delayed enhancement relies upon the intimate connection with clinical history and the cine sequence MR images.
文摘Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease.
基金the financial support from the funding for school-level research projects of Yancheng Institute of Technology(No.XJR2022019,XJ201719).
文摘A phosphine-catalyzed [4+3] annulation between dinucleophilic indole derivatives and Morita−Baylis−Hillman (MBH) carbonates was discovered by using the N1 and N4′/C4′ nucleophilicities of the indole precursors,in which indoles act as four atom synthons. This protocol provides an efficient and facile access to indole-1,2-fused 1,4-diazepinones and azepines in good to high yields in one step,which illustrates potential synthetic utilities in drug discovery.
基金financially supported by the National Key Research and Development Program of China(No.2019YFB2005801)the National Natural Science Foundation of China(Nos.51671019,51731003,51971024,51927802 and 51971023)+1 种基金Beijing Natural Science Foundation Key Program(No.Z190007)Fundamental Research Funds for the Central Universities(No.FRF-MP-19-004)。
文摘Although iron oxide(Fe_(3)O_(4)) nanoparticles have broad application prospects as magnetic resonance imaging(MRI) contrast agent, their biocompatibility and biotoxicity still need to be improved. In this study, we prepared Fe_(3)O_(4)@Angelica sinensis polysaccharide nanoparticles(Fe_(3)O_(4)@ASP NPs) with a 9 nm Fe_(3)O_(4) core and ASP as the coating material. The Fe_(3)O_(4)@ASP NPs are superparamagnetic, can be taken up by liver and spleen macrophages in the circulatory system in vivo, and are a good-biocompatibility and low-toxicity transverse relaxation time(T_(2)) and T_(2)-star(T_(2)^(*)) magnetic resonance imaging(MRI) contrast agent for the liver. The cytotoxicity assessment using HeLa cells and the pathological tests in mice validate that Fe_(3)O_(4)@ASP NPs have low toxicity and good biocompatibility in vivo, which can be attributed to the ASP as a natural polysaccharide with good biocompatibility and its function of protecting the liver. Fe_(3)O_(4)@ASP NPs are a potential new MRI contrast agent with high signal intensity in vivo.
基金Supported by The Capital Health Research and Devel-opment of Special(2020-1-2052)Science&Technology Project of Beijing Municipal Science&Technology Commission(Z201100005520045,Z181100001818003)The Beijing Municipal Administration of Hospitals’Ascent Plan(DFL20150201),The National Natural Science Foundation of China(82101180),Beijing Natural Science Foundation(7204245),Scientific Research Common Program of Beijing Municipal Commission of Education(KM202010025018),Beijing Municipal Administration of Hospitals’Youth Programme(QMS20190203),Beijing Dongcheng District Outstanding Talents Cultivating Plan(2018).
文摘Dear Editor Uveal melanoma(UM)is the most frequent primary malig-nant intraocular tumor in adults with an estimated inci-dence of 4-5 per million per year in western countries[1].About 50%of UM patients eventually develop metas-tasis.In a previous study,the prognosis of Chinese UM was mainly correlated with visual clinical features and gene sequencing results.Models designed to predict UM prognosis have been previously described[2],but these studies were based on Caucasians,not Chinese.