期刊文献+

气管套囊对麻醉兔气管黏膜形态结构影响的研究 被引量:3

Effect of inflated endotracheal tube on the tracheal mucosal morphology in anesthetized rabbits
在线阅读 下载PDF
导出
摘要 目的 :探讨气管充气套囊对麻醉兔气管黏膜形态结构的影响。方法 :家兔 12 0只 ,按气囊压力不同随机分为A( 30cmH2 O维持 1、2、4、5h)、B( 2 0cmH2 O维持 1、2、4、5h)、C( 2 0cmH2 O维持 2h气囊放气 10、2 0、30min再充气 2h)、D(对照组 ) 4组 ,分别对气管黏膜作组织学和超微结构观察。结果 :①气囊压力 2 0cmH2 O维持 2h及气囊放气 2 0min再充气 2h光镜下黏膜结构未见异常 ,电镜显示纤毛细胞质及线粒体轻度肿胀 ;2 4h后光镜和电镜观察均未见异常 ;②气囊压力 2 0cmH2 O维持≥ 4h、30cmH2 O≥ 2h气管黏膜充血、上皮细胞变性、坏死及脱落 ,拔管后 2 4h黏膜表面有黏液及坏死物覆盖 ,病变程度随气囊压迫时间延长而加重。结论 :①气囊压力以 2 0cmH2 O对气管黏膜的损伤最轻 ;②气囊充气 2h后放气≥ 2 0min再充气 ,可以减轻黏膜损伤。 Objective: To investigate the effects of inflating the cuff of endotracheal tube on tracheal mucosa in anesthetized rabbits.Methods:120 healthy adult rabbits were randomly divided into 4 groups according to the pressure of the cuff and time: A (30 cmH 2O for 1,2,4,5 h), B(20 cmH 2O for 1,2,4,5 h), C(2 h by 20 cmH 2O disinflat 10,20,30 min after reinflatly followed by 2 hours'reinflation) and D(control).Results: [WT5BZ]Compared with the control group,abnormal structure of the epithelial lamina was not seen in the group with 2 hours endotracheal tube cuff inflated to 20 cmH 2O, 20 min disinflat and 2 hours reinflate, except slight mitochondrial swelling of ciliated epithelium cells. Over 4 hours of tube cuff inflation to 20 cmH 2O and 2 hours to 30 cmH 2O, histological and ultrastructural study showed the presence of congestion, epithelial degeneration, necrosis, exfoliation, acute inflammation, hemorrhage of mesenchyma of the mucosa of retropharynx and the upper part of trachea. The damages were more severe along with the time of tube cuff inflationConclusion:Damages of tracheal mucosa were minimal when the intracuff pressure was maintained for 2 hours by 20 cmH 2O, and the damages on the mucosa could be greatly decreased if the tube was disinflated for 20 min or more once two hours.
作者 梁华 陶国才
出处 《西北国防医学杂志》 CAS 2004年第2期106-108,F003,共4页 Medical Journal of National Defending Forces in Northwest China
基金 第三军医大学科研基金资助项目 (0 1Q0 13 9)
关键词 气管黏膜 气和插管 套囊压力 电镜 光镜 Tracheal mucosa Endotracheal intubation Cuff pressure Electron microscopy Light microcopy
  • 相关文献

参考文献7

  • 1[1]Brimacombe J, Keller C, Puhringer F,et al.Pharyngeal mucosal pressure and perfusion: a fiberoptic evaluation of the posterior pharynx in anesthetized adult patients with a modified cuffed oropharyngeal airway[J]. Anesthesiology,1999,91(6): 1661-1665.
  • 2[2]Granja C, Faraldo S, Laguna P, et al. Control of the endotracheal cuff balloon pressure as a method of preventing laryngotracheal lesions in critically ill intubated patients[J]. Rev Esp Anestesiol Reanim,2002,49(3):137-140.
  • 3[3]Suzuki N, Kooguchi K, Mizobe T, et al. Postoperative hoarseness and sore throat after tracheal intubation: effect of a low intracuff pressure of endotracheal tube and the usefulness of cuff pressure indicator[J]. Masui, 1999, 48(10): 1091-1095.
  • 4[4]Somri Mostafa, Fradis Milo, Malatskey Shelton, et al. Simple on-line endotracheal cuff pressure relief valve[J]. Ann Otol Rhinol Laryngol, 2002, 111(2): 190-192.
  • 5[5]Brimacombe J, Keller C, Giampalmo M, et al. Direct measurement of mucosal pressures exertedby cuff and non-cuff portions of traceal tubes with different cuff volumes and head and neck positions[J]. Br J Anaesth , 1999, 82:708-711.
  • 6[6]Seegobin RD,van Hasselt GL.Endotracheal cuff pressure and tracheal mucosal blood flow:endoscopic study of effects of four large volume cuffs[J]. Br Med J (Clin Res) , 1984, 288: 965-968.
  • 7[7]Payne KA,Miller DM.The Miller cuff pressure control valve[J]. Clinical use in controlled and spontaneous ventilation[J]. Anaesthesia ,1993,48:324-327.