期刊文献+

基于负压波结构模式识别方法的供水管网检漏与定位技术的研究 被引量:8

The study of water pipelines leak detection and location technique based on configuration pattern recognition
在线阅读 下载PDF
导出
摘要 根据供水管网的各种工作状态,对管道压力波特征进行分析,采用上下文无关文法描述波形结构模式,构成管网各种状态波形模式库.利用模式识别的人工智能方法自动分析论断供水管网的工作状态,改进供水管网的泄漏检测与定位方法. characteristics of the water pipeline's pressure waves at all working status are analyzed, and the grammar of context free are adopted to describe the waveform configuration pattern, so the waveform pattern databases can be set up. The pattern recognition, one of the artificial intelligence technique is used to automatic analyze and judge the working states of water pipelines and to improve leak detection and location method.
出处 《广西大学学报(自然科学版)》 CAS CSCD 2003年第3期202-205,共4页 Journal of Guangxi University(Natural Science Edition)
关键词 供水管网 泄漏检漏 定位方法 负压波 管道压力波特征 模式识别 人工智能 water pipeline negative pressure wave pattern recognition
  • 相关文献

参考文献4

  • 1Wylie E.B Streeter V.L.瞬变流[M].北京:水利电力出版社,1983..
  • 2高伟.供水管道检漏的基本内容及常规方法[J].管道技术与设备,1999(4):19-21. 被引量:27
  • 3Speetra-Tek Ltd. Wavealert on duty for Britain's first major NGL pipeline [J]. Pipe and Pipelines International, 1984,29(3):26-30.
  • 4WylieEB StreeterVL.瞬变流[M].武汉:水利电力出版社,1983..

共引文献29

同被引文献62

引证文献8

二级引证文献29

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部