铜(Ⅱ)-铬天青S-过氧化氢体系催化光度法测定痕量铜 被引量:9

Study on Catalytic Spectrophotometric Determination of Trace Copper with the System of Copper-Chrome Azurol S-Hydrogen Peroxide
在线阅读 下载PDF
导出
摘要 本文研究了在氨水介质中,痕量铜对过氧化氢氧化铬天青S褪色反应的催化作用,建立了一个催化光度法测定痕量铜的新方法。线性范围为0~20ng/mL,检出限为5.59×10^(-11)g/mL,并用于铝合金标准样品,环境标准样品和自来水中痕量铜的测定。 Based on the fact that trace copper catalyzes the color-fading oxidation reaction of chrome azurol S by hydrogen peroxide in a medium of ammonia water, a new method for catalytic spectrophotometric determination of trace copper has been developed. The linear range is 0~20ng/mL and the limit of detection is 5.59×10^(-11)g/mL. It has been used to determine trace copper in standard sample of aluminium alloys, standard sample of environment and tapwater.
出处 《分析试验室》 CAS CSCD 北大核心 1992年第5期46-47,共2页 Chinese Journal of Analysis Laboratory
关键词 铬天青S 过氧化氢 催化光度法 Copper-chrome azurol S-hydrogen peroxide catalytic spectrophotometry copper determination aluminium alloys