灰阶血流成像技术与CDFI在穿支皮瓣术前定位中的对比研究 被引量:1

Comparison of B-mode blood flow imaging technique and CDFI in the preoperative localization of perforator flaps
在线阅读 下载PDF
导出
摘要 目的比较灰阶血流成像(B-flow)与CDFI在穿支皮瓣术前定位中的价值。方法选取在我院接受皮瓣移植术的患者30例,术前分别应用CDFI和B-flow检测皮瓣供区的穿支血管,定位并标记最优穿支的穿出点;术中分别测量CDFI、B-flow定位穿刺点到术中确定穿出点的距离(AC值、BC值),比较二者检查耗时及显示穿支血管数目,以及AC值与BC值的差异。结果B-flow的检查耗时少于CDFI检测耗时[(6.700±1.207)min vs.(10.333±1.398)min],检测穿支血管数量多于CDFI所测[(3,1)vs.(2,0)],BC值小于AC值[(4.233±1.194)mm vs.(5.667±1.917)mm],差异均有统计学意义(均P<0.05)。结论B-flow对穿支血管的检测优于CDFI,且其定位更加准确。 Objective To compare the value of B-mode blood flow imaging(B-flow)and CDFI in preoperative localization of perforator flaps.Methods A total of 30 patients who underwent flap transplantation in our hospital was enrolled.CDFI and B-flow were used to detect the number of perforator vessels in the donor area of the flap before surgery,and the outlet point of the optimal perforator was located and marked.The distance from the puncture point to the outlet point was recorded as AC value of CDFI and BC value of B-flow,respectively during surgery.The examination time and the number of perforators of CDFI and B-flow and the difference between AC value and BC value were compared.Results The examination time of B-flow was less than that of CDFI[(6.700±1.207)min vs.(10.333±1.398)min].The number of perforators detected by B-flow was more than that of CDFI[(3,1)vs.(2,0)].And the BC value was less than the AC value[(4.233±1.194)mm vs.(5.667±1.917)mm].All the differences were statistically significant(all P<0.05).Conclusion B-flow is more effective than CDFI in detecting perforator vessels,and the localization of perforator vessels is more accurate.
作者 林金淼 黄高峰 谢钦赐 李靖云 林海滨 陈意玲 吕国荣 LIN Jinmiao;HUANG Gaofeng;XIE Qinci;Li Jingyun;LIN Haibin;CHEN Yiling;LV Guorong(Department of Ultrasound Medicine,Jinjiang Municipal Hospital,Fujian 362200,China)
出处 《临床超声医学杂志》 CSCD 2021年第8期630-632,共3页 Journal of Clinical Ultrasound in Medicine
关键词 灰阶血流成像 CDFI 穿支皮瓣 穿支血管 B-mode blood flow imaging CDFI Perforator flap Perforator vessel
  • 相关文献

参考文献1

二级参考文献42

  • 1Taylor GI,Palmer JH.The vascular territories (angiosomes) of the body: experimental study and clinical applications[J]. Br J Plast Surg, 1987,40 (2):113-141.
  • 2Aoyagi F,Fujino T, Ohshiro T.Detection of small vessels for microsurgery by a Doppler flowmeter[J]. Plast Reconstr Surg, 1975,55 (3):372-373.
  • 3Taylor GI, Doyle M, McCarten G. The Doppler probe for planningflaps: anatomical study and clinical applications[J].Br J Plast Surg, 1990, 43(1): 1-16.
  • 4Yu P, Youssef A.Efficacy of the Handheld Doppler in Preoperative Identification of the Cutaneous Perforators in the Anterolateral Thigh Flap[J]. Plast Reconstr Surg, 2006, 118(4):928-933.
  • 5Halock GG. Evaluation of fasciocutaneous perforators using color duplex imaging[J]. Plast Reeonstr Surg, 1994, 94:644-651.
  • 6Tsukino A,Kurachi K,Inamiya T, et al.Preoperative color Doppler assessment in planning of anterolateral thigh flaps[J]. Plast Reconstr Surg, 2004,113:241-246.
  • 7Isken T, Alagoz MS, Onyedi M, et al. Preoperative color Doppler assessment in planning of gluteal perforator flaps[J]. Ann Plast Surg, 2009, 62(2): 158-163.
  • 8I Su W, Lu L,Lazzeri D,et al.Contrast-enhanced ultrasound combined with three-dimensional reconstruction in preoperative perforator flap planning.Plast Reconstr Surg,2013,131(1):80-93.
  • 9Harder T, Deroover M,Stark GB,et al. Angiography findings before and following transplantation of free myocutaneous flaps[J]. Rontgenblatter, 1990,43:41-45.
  • 10郝敏,刘安庆,李美才,等.用数字减影血管造影选择皮瓣供区修复小腿下段、足部软组织缺损[J].中华创伤杂志,2005,21(8):34-37.

共引文献19

同被引文献7

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部