期刊文献+

基于Patlak Plots法两次大螺距前瞻性心电门控扫描模式冠状动脉CT血管成像评估心肌血流灌注的可行性 被引量:3

Myocardial perfusion evaluation by using Double FLASH coronary artery CT angiography based on Patlak Plots
原文传递
导出
摘要 目的:探讨基于原始Patlak Plots法,应用两次大螺距前瞻性心电门控扫描模式(Double FLASH)冠状动脉CTA(CCTA)评估心肌血流灌注的可行性。方法:前瞻性纳入2018年1月至2020年1月因冠心病或疑似冠心病于天津医科大学总医院行负荷动态心肌CT灌注(CTP)+CTA扫描的非缺血性心脏病受试者。入组患者年龄>18岁且CTA上无中度以上狭窄。使用FRONTIER平台分析软件进行动态CTP分析,并计算心肌血流量(MBF CTP)。通过测量Double FLASH扫描2个时间点的主动脉和心肌的CT衰减值来计算MBF CTA。使用线性回归、Pearson相关性和Bland-Altman分析比较MBF CTP和MBF CTA结果。结果:本研究共纳入50例受试者。MBF CTA与MBF CTP存在线性相关,室间隔中部:MBF CTA=0.936MBF CTP-11.999,r^(2)=0.600,P<0.01;左心室游离壁:MBF CTA=1.010MBF CTP-9.206,r^(2)=0.448,P<0.01;心尖部:MBF CTA=0.822MBF CTP+16.904,r^(2)=0.375,P<0.01。Bland-Altman分析显示,MBF CTA与MBF CTP的测量结果无显著偏差。与动态CTP扫描[(4.33±1.89)mSv]相比较,Double FLASH扫描明显降低了辐射剂量[(1.38±0.19)mSv],差异具有统计学意义(t=4.378,P=0.030)。结论:本研究以CTP为参考标准,验证了基于Patlak Plots理论、利用Double FLASH CCTA图像计算MBF方法的可行性和一致性,该方法有潜力为同时评估冠状动脉与心肌缺血状态的一站式检查拓展临床应用前景。 Objective To explore the feasibility of using Double FLASH coronary CTA(CCTA)to evaluate myocardial blood perfusion based on the original Patlak Plots.Methods A total of 50 subjects with non-ischemic heart disease were prospectively included in the study who received dynamic myocardial CT perfusion(CTP)and Double FLASH CTA scans in General Hospital of Tianjin Medical University from January 2018 to January 2020 due to coronary heart disease or suspected coronary heart disease.The age of the enrolled patients was at least 18 years old and there was no moderate or above stenosis on CTA.The dynamic CTP images were analyzed by using CTP analysis software on FRONTIER platform to calculate the CTP derived MBF(MBFCTP).While the CTA derived MBF(MBFCTA)was calculated from the CT attenuation values of both aorta and myocardium segments on two scanning time set of Double FLASH CTA which were measured by two independent radiologists.Pearson correlation and Bland-Altman analysis were used to compare the results of MBFCTP and MBFCTA.Results There was a strong linear correlation between MBFCTP and MBFCTA measurements.In the mid anteroseptal level:MBFCTA=0.936MBFCTP-11.999,r²=0.600,P<0.01.In the mid anterolateral level:MBFCTA=1.010MBFCTP-9.206,r²=0.448,P<0.01.In the apex:MBFCTA=0.822MBFCTP+16.904,r²=0.375,P<0.01.Bland-Altman analysis also showed there were no significant differences between MBFCTP and MBFCTA measurements.Compared with dynamic CTP scan,Double FLASH CTA mode significantly reduced the radiation dose[(4.33±1.89)mSv vs.(1.38±0.19)mSv,t=4.378,P=0.030].Conclusions This study validated the feasibility and accuracy of the MBFCTA measurement based on the theory of Patlak Plots only using Double FLASH CTA images.This method might have the potential to expand the clinical application of one-stop CTP examination for simultaneously evaluating coronary artery and myocardial ischemia in the clinic.
作者 门玥琪 张璋 吴梦姗 南丽虹 李睿君 李慧瑶 杨帆 李锋坦 李东 Men Yueqi;Zhang Zhang;Wu Mengshan;Nan Lihong;Li Ruijun;Li Huiyao;Yang Fan;Li Fengtan;Li Dong(Department of Radiology,Tianjin Medical University General Hospital,Tianjin 300052,China)
出处 《中华放射学杂志》 CAS CSCD 北大核心 2021年第6期638-643,共6页 Chinese Journal of Radiology
基金 国家自然科学基金(81301217,81301202) 天津市自然科学基金(14JCZDJC57000,18JCYBJC25100) 科学技术部“十三五”重点专项(2016YFC1300400)。
关键词 冠状动脉疾病 心肌缺血 体层摄影术 X线计算机 心肌灌注成像 Coronary artery disease Myocardial ischemia Tomography,X-ray computed Myocardial perfusion imaging
  • 相关文献

参考文献3

二级参考文献12

共引文献1817

同被引文献33

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部