摘要
介绍了某机场三联供能源站的接入系统及燃气发电机组选型,包括发电系统运行方式、接入系统设置、并网系统继电保护措施、燃气发电机类型选择、发电机组分组、台数及单机容量选择等,可为类似项目设计提供参考。
The access system and gas generator type selection of an airport triple-supply energy station were introduced,including the operation mode of the power generation system,the setting of the access system,the relay protection measures of the grid-connected system,the selection of the gas generator type,and the group and units number of generator,the selection of single-machine capacity.It can provide references for the design of similar projects.
作者
黄宇清
HUANG Yuqing(Guangdong Architecural Design&Research Institute Co.,Ltd.,Guangzhou 510010,China)
出处
《现代建筑电气》
2021年第1期36-41,共6页
Modern Architecture Electric
关键词
并网运行
接入系统
继电保护
负荷分析
负荷预测
发电机组台数
发电机组单机容量
grid-connected operation
access system
relay protection
load analysis
load forecast
number of generating units
single unit capacity of generating units