期刊文献+

电气与腐蚀试验对铜覆钢接地材料性能的影响分析 被引量:1

Analysis of influence of electrical and corrosion tests on grounding properties of copper clad steel
在线阅读 下载PDF
导出
摘要 通过模拟铜覆钢接地材料在使用环境中可能遇到的问题,对铜覆钢接地材料分别进行电流—温度循环试验、冰冻—融化试验、中性盐雾腐蚀试验、工频大电流试验;并对试验结果进行分析和研究。研究结果表明,试验过程对接地材料的组织和力学性能和电阻有一定的影响,抗拉强度和屈服强度有一定下降,但仍然能满足标准要求;电阻值变化较小,对材料的使用不会造成太大影响。 By simulating the potential problems of copper-clad steel earthing materials in the use environment,the current-temperature cycle test,freeze-thaw test,neutral salt spray corrosion test and power frequency large current test were carried out for copper-clad steel earthing materials.The experimental results are analyzed and studied.The results show that the tensile strength and yield strength decrease to some extent,but still meet the standard requirements.The change of resistance value is small,which will not have great influence on the use of materials.
作者 潘学东 赵蕊 王晓芳 PAN Xue-dong;ZHAO Rui;WANG Xiao-fang(Global Energy Interconnection Research Institute Co.,LTD,Beijing 102209 China)
出处 《世界有色金属》 2020年第20期128-130,共3页 World Nonferrous Metals
关键词 电气与腐蚀 铜覆钢 电阻 显微组织 力学性能 electrical and corrosion copper clad steel resistance microstructure mechanical properties