摘要
针对目前国内外冲击电压分压器计量的技术状态,分析国内冲击分压器及其测量系统的技术发展水平,提出国内分压器校准应积极参加国际比对的必要性。并在此基础上,提出冲击分压器及其测量系统线性度研究的必要性及其方法,以及对于1000 kV以上标准分压器的校准进展和逐级比对研究方法。
According to the state of technology at home and abroad impulse voltage divider measurement technology,the development level of divider and its measuring system of domestic shocks,proposed the necessity of divider calibration should actively participate in domestic and international comparison.On this basis,it is necessary to study the linearity of impact voltage divider and its measurement system,as well as the progress of calibration and the method of step by step comparison of the 1000 kV standard divider.
作者
盛诗敏
佟西伟
Sheng Shi-min;Tong Xi-wei
出处
《电力系统装备》
2020年第22期195-196,共2页
Electric Power System Equipment
关键词
分压器计量
线性度
逐级比对
divider measurement
linearity
step by step comparison