期刊文献+

基于ICEPAK的就地化装置热设计

Thermal design of locally installed device based on ICEPAK
在线阅读 下载PDF
导出
摘要 针对就地化装置内部空间小、局部热量高、密封等级高的特点进行了热设计,采用"机箱一体化"的散热设计方案,同时局部采用导热衬垫优化热阻,解决装置的散热问题。通过有限元仿真软件ICEPAK对某就地化保护装置的设计方案进行了系统级热仿真分析,得到了装置内部的温度分布特点,并通过热测试试验与仿真结果进行对比,验证仿真的真实性与可靠性。 Thermal design is made according to the characteristics of locally installed device which has small internal space,high localized heat and high sealing level. It adopts‘integratedcase'as layout scheme and adopts thermal conduction pad to optimize thermal resistance,which solve the problem of heat dissipation of the device. Meanwhile system thermal simulation analysis is made on locally installed protection device by finite element simulation software ICEPAK,by which the temperature distribution inside the device can be obtained. Comparing thermal test results with simulation results,it shows that the simulation results are authentic and reliable.
出处 《华电技术》 CAS 2018年第4期16-18,共3页 HUADIAN TECHNOLOGY
关键词 ICEPAK 有限元 就地化装置 热设计 ICEPAK finite element locally installed device thermal design
  • 相关文献

参考文献3

二级参考文献26

  • 1李建基.高压气体绝缘金属封闭开关设备(GIS)的主要合资企业概况及产品[J].电力设备,2007,8(3):114-115. 被引量:6
  • 22005/2006 IEEE PES输配电会议和展览资料[Z].
  • 3GB 50059-1992.35 kV-110kV变电所设计规范[S].,..
  • 4GB 50060-1992,35 kV-110 kV高压配电装置设计技术规范[S].
  • 5DL/T 5056-1996.变电所总布置设计技术规程[S].,..
  • 6浙江省电力工业局.农村电网35 kV变电所典型设计方案[M].北京:中国电力出版社.
  • 7DIN-47636,电力电缆插套组合配件[Z].
  • 8IEC 60859..额定电压72.5 EV及以上气体绝缘金属封闭开关设备的电缆连接充流体和挤压绝缘电缆充流体和干型电缆终端[S]..,,....
  • 9国家电网公司.国家电网公司"十一五"科技发展规划[Z].
  • 10国家电网公司.国家电网公司农网"十一五"科技发展规划纲要[Z].