期刊文献+

4D Flow MRI技术临床应用的研究进展 被引量:11

Research advances in clinical application of 4D Flow MRI
在线阅读 下载PDF
导出
摘要 4D Flow MRI技术是一种新型相位对比MR技术,可同时对三个相互垂直的维度进行相位编码,多方向采集血流数据,从而获得复杂的三维动力学参数。与2D相位对比MRI以及传统的多普勒超声心动图等技术相比,4D Flow MRI技术准确率更高、成像更全面,同时其也有一定的缺点,如扫描时间长、噪声大等,也是今后需解决的关键技术问题。目前4D Flow MRI主要应用于颅内血管病变成像以及心脏MR方面,同时其对主动脉疾病等方面的应用也有一定的前景。本文旨在对4D Flow MRI技术的研究进展进行综述。 4D Flow MRI is a new phase contrast MR technique, which can spatially encode velocity in three-direction, collect multi-directional blood flow data, and result in complex three-dimensional dynamic parameters. 4D Flow MRI is more accurate and comprehensive than 2D phase contrast MRI and Doppler echocardiography. However, 4D Flow MRI have some disadvantages, such as long scanning time, noise, etc., which are the future key technical issues to be addressed. 4D Flow MRI technology has a great potential in clinical applications, such as intracranial vascular diseases, cardiac magnetic resonance imaging, and other aspects of aortic diseases. Research advances in clinical application of 4D Flow MRI were reviewed in this paper.
出处 《中国医学影像技术》 CSCD 北大核心 2017年第12期1898-1901,共4页 Chinese Journal of Medical Imaging Technology
基金 国家自然科学基金资助项目(81671667、81471644) 中国博士后基金资助项目(2016T90445)
关键词 相位对比技术 磁共振成像 血流动力学 血管壁参数 Phase contrast technique Magnetic resonance imaging Hemodynamics Vascular wall parameters
  • 相关文献

参考文献3

二级参考文献47

  • 1Shah SJ.Pulmonary hypertension.JAMA,2012,308(13):1366-1374.
  • 2Thenappan T,Shah SJ,Rich S,et al.Survival in pulmonary arterial hypertension: a reappraisal of the NIH risk stratification equation.Eur Respir J,2010,35(5):1079-1087.
  • 3Markl M,Harloff A,Bley TA,et al.Time-resolved 3D MR velocity mapping at 3T:improved navigator-gated assessment of vascular anatomy and blood flow. J Magn Reson Imaging, 2007,25(4):824-831.
  • 4Markl M,Chan FP,Alley MT,et al.Time-resolved threedimensional phase-contrast MRI.J Magn Reson Imaging,2003,17(4):499-506.
  • 5Frydrychowicz A,Stalder AF,Russe MF,et al.Threedimensional analysis of segmental wall shear stress in the aorta by flow-sensitive four-dimensional-MRI.J Magn Reson Imaging,2009,30(1):77-84.
  • 6Bock J,Kreher BW,Hennig J,et al.Optimized pre-processing of time-resolved 2D and 3D phase contrast MRI data//Proceedings of the 15th Annual Meeting of ISMRM,Berlin,2007:3138.
  • 7Bock J,Frydrychowicz A,Stalder AF,et al.4D phase contrast MRI at 3 T:effect of standard and blood-pool contrast agents on Snr, PC-MRA, and blood flow visualization. Magn Reson Med, 2010,63(2):330-338.
  • 8Stalder AF,Russe MF,Frydrychowicz A,et al.Quantitative 2D and 3D phase contrast MRI:optimized analysis of blood flow and vessel wall parameters.Magn Reson Med,2008,60(5):1218-1231.
  • 9Balleux-Buyens F,Jolivet O,Bittoun J,et al.Velocity encoding versus acceleration encoding for pressure gradient estimation in MR haemodynamic studies.Phys Med Biol,2006,51(19):4747-4758.
  • 10Yang GZ,Kilner PJ,Wood NB,et al.Computation of flow pressure fields from magnetic resonance velocity mapping.Magn Reson Med,1996,36(4):520-526.

共引文献39