摘要
消防新规实施后,电气设计中遇到了矿物绝缘电缆的选择、消防泵启动、区域火灾自动报警系统的联动控制、防火门监控的设置、电气火灾监控及消防电源监控设置等许多问题,针对这些问题,提出了具体的解决和处理办法,以供参考。
After the implementation of new code for fire, there are many problems in e- lectrical design, such as Choice of mineral insulated cable, Starting of fire pump, Setting of the regional fire alarm and automatic control system, Setting of the fire door monitor, Setting of electrical fire monitor and the fire power st, pply monitor. In view of these prob- lems, there are some specific and practical methods put forward for your reference.
作者
苏志军
蔡岷
Su Zhijun Cai Min
出处
《智能建筑电气技术》
2017年第5期47-50,共4页
Electrical Technology of Intelligent Buildings
关键词
矿物绝缘电缆
区域火灾报警系
统防火门监控
电气火灾监控
消防电源监控
mineral insulated cable, regional fire alarm system, fire door monitor, elec- trical fire monitoring, fire power supply monitoring