期刊文献+

^(85)Kr气体液闪测量方法研究 被引量:2

Determination of ^(85)Kr by Liquid Scintillation
在线阅读 下载PDF
导出
摘要 采用反康普顿γ谱仪对^(85)Kr样品进行活度标定作为工作参考,通过自行设计的Kr气体收集装置和液闪制样装置,建立了一种^(85)Kr气体样品的液闪测量方法。结果表明:以甲苯为溶剂、1,4-双-2-(4-甲基-5-苯基噁唑基)(POPOP)和2,5-2苯基噁唑(PPO)为溶质的闪烁液,当体积为20mL,硅胶加入质量为1.0g时,能够完全溶解0.5m^3空气中的Kr气,且样品液闪测量无需进行淬灭校正;对于^(85)Kr活度小于1Bq的样品,液闪测量相对偏差绝对值小于7%;制备的样品放置20h以内计数率稳定。该方法适用于环境大气中^(85)Kr放射性水平的测量。 With a known activity of ^85Kr standardized by Anti-Comptonγspectrometer as working standards,and with a set of self-designed Kr collection and liquid scintillation sample preparation device,the radioactive measurement method of ^85Kr by liquid scintillation was established.Experimental results show that,under the condition of toluene used as solvent,PPO and POPOP used as solute,and 1.0g silicone added into the liquid,Kr sample can be completely dissolved in 20 mL scintillation liquid and its activity can be determined without quenching correction.The absolute value of relative error less than 7% can be reached when ^85Kr activity is lower than 1Bq in the sample.The sample stability is proved by compared with the counting of sample measurements in the interval 20 h.The device and method established can be applied to the measurement of environmental atmospheric ^85Kr activity concentration.
出处 《核化学与放射化学》 CAS CSCD 北大核心 2017年第1期90-94,共5页 Journal of Nuclear and Radiochemistry
关键词 ^85Kr 硅胶 液闪测量 制样 ^85Kr silicone liquid scintillation measurement sample preparation
  • 相关文献

参考文献1

二级参考文献3

  • 1袁本良 谈德清.环境中的氪与氙[M].北京:原子能出版社,1983..
  • 2Stevenson D L 美国环境保护委员会.测定环境中^85Kr的分离技术,IAEA-SM-148/68[M].,..
  • 3Cummings S L 美国环境保护委员会.测定环境空气样品中^85Kr的快速方法,IAEA-SM-148/11[M].,..

共引文献9

同被引文献2

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部