期刊文献+

Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures 被引量:14

Biomechanical comparison of locking plate and crossing metallic and absorbable screws fixations for intra-articular calcaneal fractures
原文传递
导出
摘要 The locking plate and percutaneous crossing metallic screws and crossing absorbable screws have been used clinically to treat intra-articular calcaneal fractures, but little is known about the biomechanical differences between them. This study compared the biomechanical stability of calcaneal fractures fixed using a locking plate and crossing screws. Three-dimensional finite-element models of intact and fractured calcanei were developed based on the CT images of a cadaveric sample. Surgeries were simulated on models of Sanders type III calcaneal fractures to produce accurate postoperative models fixed by the three implants. A vertical force was applied to the superior surface of the subtalar joint to simulate the stance phase of a walking gait. This model was validated by an in vitro experiment using the same calcaneal sample. The intact calcaneus showed greater stiffness than the fixation models. Of the three fixations, the locking plate produced the greatest stiffness and the highest von Mises stress peak. The micromotion of the fracture fixated with the locking plate was similar to that of the fracture fixated with the metallic screws but smaller than that fixated with the absorbable screws. Fixation with both plate and crossing screws can be used to treat intra-articular calcaneal fractures. In general, fixation with crossing metallic screws is preferable because it provides sufficient stability with less stress shielding. The locking plate and percutaneous crossing metallic screws and crossing absorbable screws have been used clinically to treat intra-articular calcaneal fractures, but little is known about the biomechanical differences between them. This study compared the biomechanical stability of calcaneal fractures fixed using a locking plate and crossing screws. Three-dimensional finite-element models of intact and fractured calcanei were developed based on the CT images of a cadaveric sample. Surgeries were simulated on models of Sanders type III calcaneal fractures to produce accurate postoperative models fixed by the three implants. A vertical force was applied to the superior surface of the subtalar joint to simulate the stance phase of a walking gait. This model was validated by an in vitro experiment using the same calcaneal sample. The intact calcaneus showed greater stiffness than the fixation models. Of the three fixations, the locking plate produced the greatest stiffness and the highest von Mises stress peak. The micromotion of the fracture fixated with the locking plate was similar to that of the fracture fixated with the metallic screws but smaller than that fixated with the absorbable screws. Fixation with both plate and crossing screws can be used to treat intra-articular calcaneal fractures. In general, fixation with crossing metallic screws is preferable because it provides sufficient stability with less stress shielding.
出处 《Science China(Life Sciences)》 SCIE CAS CSCD 2016年第9期958-964,共7页 中国科学(生命科学英文版)
基金 supported by the Shanghai Municipal Commission of Health and Family Planning(20144Y0250,20134Y207) the National Natural Science Foundation of China(11302154,11272273) The Hong Kong Research Grant Council GRF(PolyU152216/14E,PolyU5326/11E)
关键词 finite-element analysis in vitro experiment calcaneal fracture plate fixation absorbable screw BIOMECHANICS 骨折固定 生物力学 固定治疗 可吸收 螺钉 跟骨 钢板 关节
  • 相关文献

参考文献4

二级参考文献35

  • 1孙秀珍,于驰,刘迎曦,于申,张军,苏英锋.人体上呼吸道三维有限元重建与流场数值模拟[J].航天医学与医学工程,2006,19(2):129-133. 被引量:23
  • 2刘永义,包亚军,刘文华,姚大康,覃开蓉,蒋琳辉,桑琛.阻塞性睡眠呼吸暂停低通气综合征患者睡眠呼吸暂停事件前后咽腔呼吸压力的分析[J].中华内科杂志,2006,45(11):914-917. 被引量:9
  • 3Xiuzhen Sun Chi Yu Yuefang Wang Yingxi Liu State Key Lab.of Struct.Anal.for Ind.Equip.,Dalian University of Technology,Dalian 116024,China The Second Affiliated Hospital,Dalian Medical University,Dalian 116027,China.Numerical simulation of soft palate movement and airflow in human upper airway by fluid-structure interaction method[J].Acta Mechanica Sinica,2007,23(4):359-367. 被引量:9
  • 4K. M. Patil,L. H. Braak,A. Huson.Analysis of stresses in two-dimensional models of normal and neuropathic feet[J] ,1996
  • 5Taniguchi,A,Tanaka,Y,Takakura,Kadono,K,Maeda,M,Yamamoto,H.Anatomy of the spring ligament. Journal of Bone and Joint Surgery British Volume . 2003
  • 6Brekelmans WA,Poort HW,Slooff TJ.A new method to analyse the mechanical behaviour of skeletal parts. Acta Orthopaedica . 1972
  • 7Gefen A.Stress analysis of the standing foot following surgical plantar fascia release. Journal of Biomechanics . 2002
  • 8Jacob S,Patil MK.Three-dimensional foot modeling and analysis of stresses in normal and early stage hansen’ s disease with muscle paralysis. Journal of Rehabilitation . 1999
  • 9Gefen A,Megido-Ravid M,Itzchak Y,et al.Biomechanical analysis of the three-dimensional foot structure during gait: a basic tool for clinical applications. Journal of Biomechanical Engineering Transactions of the ASME . 2000
  • 10Sarrafian S K.Functional characteristics of the foot and plantar aponeurosis under tibiotalar loading. Foot Ankle . 1987

共引文献29

同被引文献86

引证文献14

二级引证文献63

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部