期刊文献+

Infrared Imaging Bolometer for the HL-2A Tokamak

Infrared Imaging Bolometer for the HL-2A Tokamak
在线阅读 下载PDF
导出
摘要 An infrared imaging bolometer diagnostic has been upgraded recently to be adapted for the complications of the signal-to-noise ratio arising from the low level of plasma radiation and high reflectivity of low energy photon(〈6.2 eV).It utilizes a platinum foil,blackened on both sides with graphite spray,as the bolometer detector.The advantage of the blackened foil is the light absorption extending into the infrared.After a careful calibration of the foil,the incident power density distribution on the foil is determined by solving the heat diffusion equation with a numerical technique.The local plasma radiated power density is reconstructed with a minimum fisher information regularization method by assuming plasma emission toroidal symmetry.Comparisons of the results and the profiles measured by an ordinary bolometric detector demonstrate that this method is good enough to provide the plasma radiated power pattern.The typical plasma radiated power density distribution before and after high mode(H-mode) transition is firstly reconstructed with the infrared imaging bolometer.Moreover,during supersonic molecular beam injection(SMBI),an enhanced radiation region is observed at the edge of the plasma. An infrared imaging bolometer diagnostic has been upgraded recently to be adapted for the complications of the signal-to-noise ratio arising from the low level of plasma radiation and high reflectivity of low energy photon(〈6.2 eV).It utilizes a platinum foil,blackened on both sides with graphite spray,as the bolometer detector.The advantage of the blackened foil is the light absorption extending into the infrared.After a careful calibration of the foil,the incident power density distribution on the foil is determined by solving the heat diffusion equation with a numerical technique.The local plasma radiated power density is reconstructed with a minimum fisher information regularization method by assuming plasma emission toroidal symmetry.Comparisons of the results and the profiles measured by an ordinary bolometric detector demonstrate that this method is good enough to provide the plasma radiated power pattern.The typical plasma radiated power density distribution before and after high mode(H-mode) transition is firstly reconstructed with the infrared imaging bolometer.Moreover,during supersonic molecular beam injection(SMBI),an enhanced radiation region is observed at the edge of the plasma.
出处 《Plasma Science and Technology》 SCIE EI CAS CSCD 2016年第6期590-594,共5页 等离子体科学和技术(英文版)
基金 supported by National Natural Science Foundation of China(Nos.10805016 and 11175061) the Chinese National Fusion Projectfor ITER(No.2014GB109001)
关键词 infrared imaging bolometer TOMOGRAPHY plasma radiated power pattern infrared imaging bolometer tomography plasma radiated power pattern
  • 相关文献

参考文献17

  • 1Boivin R L, Goetz .J A, Marmar E S, et al. 1999, Rev. Sci. Instrum., 70:260.
  • 2Meister H, Giannone L, Horton L D, et al. 2008, Rev. Sci. Instrum., 79:10F511.
  • 3Strait E 3. 2015, Physics of Plasmas, 22:021803.
  • 4Peterson B J, Miyazama J, Nishimura K, et al. 2006, Plasma and Fusion Research, 1:45.
  • 5Peterson B J, Osakabe M, Shoji M, et al. 2001, Rev. Sci. Instrum., 72:923.
  • 6Peterson B J. 2000, Rev. Sci. Instrum., 71:3696.
  • 7Wurden G A and Peterson B J. 1999, Rev. Sci. Instrum., 70:255.
  • 8Liu Y, Tamura N, Peterson B J, et al. 2007, Plasma and Pusion Research, 2:$1124.
  • 9Harris L, Mcginnies R T, Siegel B M. 1948, J. Opt. Soc. Am., 38:582.
  • 10Gao J M, Liu Y, Li W, et al. 2013, Rev. Sci. Instrum., 84:093503.