摘要
目的:探讨血液分析仪检测网织红细胞参数在贫血诊断中的临床价值。方法:选取确诊的271例贫血患者,按照贫血类型将其分为缺铁性贫血组(126例)和失血性贫血组(145例),即观察组;另选取50名健康体检者为对照组,采用Sysmex XE-5000全自动五分类血液分析仪对其网织红细胞参数检测,分析比较网织红细胞(RET)比率、高荧光网织红细胞(HFR)比率、中荧光网织红细胞(MFR)比率和未成熟网织红细胞(IRF)比率。结果:观察组与对照组比较,其RET、HFR、MFR和IRF均明显高于对照组;观察组中缺铁性贫血和失血性贫血的灵敏度分别为96.2%,63.5%;贫血的特异度是96.0%。结论:利用Sysmex XE-5000全自动五分类血液分析仪,检测网织红细胞各参数可反映贫血患者的骨髓增生情况,对各类贫血的诊断具有较高的灵敏度和特异性,在临床的诊治过程中具有较高实用价值。
Objective: To investigate clinical value of the blood analyzer reticulocyte parameter in the diagnosis of anemia. Methods: 271 cases of anemia patients were divided into iron deficiency anemia(126 cases) and hemorrhagic anemia group(145 cases), namely the observation group; and other 50 healthy physical examinees were selected as the control group. Sysmex XE-5000 automatic blood analyzer were used to detect the reticulocyte parameters, including reticulocytes(RET) ratio, high fluorescence reticulocytes(HFR) ratio of middle fluorescence reticulocytes(MFR) ratio and the immature reticulocytes(IRF) ratio. Results: Compared with the control group, the RET, HFR, MFR and IRF were significantly higher in the observation group. The sensitivity of iron deficiency anemia and blood loss anemia was 96.2% and 63.5%; the specificity of anemia was 96.0%. Conclusion: Detection of reticulocyte parameters can reflect the marrow hyperplasia patients with anemia. It has a high sensitivity and specificity in the diagnosis of various types of anemia, which has a high practical value in clinic.
出处
《中国医学装备》
2016年第3期88-90,共3页
China Medical Equipment
关键词
网织红细胞参数
贫血
骨髓增生
检测
Reticulocyte parameters
Anemia
Bone marrow hyperplasia
Detection