期刊文献+

Carbon dioxide digital subtraction angiography manifestations of hepa-tocellular carcinoma 被引量:2

Carbon dioxide digital subtraction angiography manifestations of hepa-tocellular carcinoma
在线阅读 下载PDF
导出
摘要 Objective: To investigate the imaging features and clinical significance of carbon dioxide digital subtraction angiography (CO2-DSA) in the diagnosis and treatment of hepatocellular carcinoma (HCC). Methods: Both CO2-DSA and conventional DSA were performed in all 47 patients with HCC, and the angio-graphic manifestations of CO2-DSA were compared with those of conventional DSA in the same patients. Results: Peripheral arterial and capillary imaging by CO2-DSA was inferior to that by conventional DSA, although blood pools were well visualized with CO2. Improved visualization of arterioportal shunting (APS) was obtained with CO2-DSA compared with that by conventional angiography. APS was observed in 33 cases by CO2-DSA and in 12 cases by conventional angiography (P<0. 001). Retrograde visualization of the portal vein (PV) trunk and its large branches was demonstrated in 16 cases by CO2-DSA and in 1 case by conventional DSA (P<0. 001). The manifestation of lipiodol retention in the tumors was consistent with CO2-DSA images after TAE in 38 cases, and with those of conventional DSA in 23 cases (P<0. 01). Conclusion: CO2-DSA was superior to conventional DSA in the detection of APS and retrograde visualization of PV system, and the former can provide usefulness information for the treatment planning (chemoembolization) and patient prognosis. Demonstration of APS by CO2-DSA may suggest the presence of intrahepatic metastases. Objective: To investigate the imaging features and clinical significance of carbon dioxide digital subtraction angiography (CO2-DSA) in the diagnosis and treatment of hepatocellular carcinoma (HCC). Methods: Both CO2-DSA and conventional DSA were performed in all 47 patients with HCC, and the angio-graphic manifestations of CO2-DSA were compared with those of conventional DSA in the same patients. Results: Peripheral arterial and capillary imaging by CO2-DSA was inferior to that by conventional DSA, although blood pools were well visualized with CO2. Improved visualization of arterioportal shunting (APS) was obtained with CO2-DSA compared with that by conventional angiography. APS was observed in 33 cases by CO2-DSA and in 12 cases by conventional angiography (P<0. 001). Retrograde visualization of the portal vein (PV) trunk and its large branches was demonstrated in 16 cases by CO2-DSA and in 1 case by conventional DSA (P<0. 001). The manifestation of lipiodol retention in the tumors was consistent
出处 《Journal of Medical Colleges of PLA(China)》 CAS 2002年第1期60-64,共5页 中国人民解放军军医大学学报(英文版)
  • 相关文献

参考文献13

  • 1[1]Paul RE, Durant TM, Oppenheimer MJ et al. Intravenous carbon dioxide for intracardiac gas contrast in roentgen diagnosis of pericardial effusion and thinckening [J]. AJR, 1957;78(2):224
  • 2[2]Kerns SR, Hawkins IF, Sabetal FW. Current status of carbon dioxide angiography [J]. Radiol Clin North Am, 1995;33(1) :15
  • 3[3]Hawkins IF, Garidi JG. Carbon dioxide (CO2) digital subtraction angiography: 26-year experience at university of Florida [J]. Eur Radiol, 1998;8(4):391
  • 4[4]Hawkins IF, Caridi JG. CO2 digital subtraction arteriography-Advantages and current solutions for dilivery and imaging [J]. Cardiovasc Intervent Radiol, 1995;18(3):150
  • 5[5]Sullion KI, Bonn J, Shapiro MJ et al. Venography with carbon dioxide as a contrast agent [J]. Cardiovasc Intervent Radiol, 1995;18(3):141
  • 6[6]Fleiss JL. Measuring agreement between two judges on the presence or absence of a trait [J]. Biometrics, 1975;31(3) :651
  • 7[7]Hawkins IF. Carbon dioxide digital subtraction angiography [J]. AJR,1982;139(1):19
  • 8[8]Weaver FA, Pentecost MJ, Yellin AE et al. Clinical applications of carbon dioxide/digital subtraction arteriography [J] J Vasc Surg, 1991; 13(2):266
  • 9[9]Boyd-Kranis R, Sullivan K1, Eschelman DJ et al. Accuracy and safety of carbon dioxide inferior vena cavography [J]. J Vasc Intervent Radiol, 1999;
  • 10[10](10):118310.Caridi IG, Hawkins IF. CO2 digital subtraction angiography: Potential complications and their prevention [J]. J Vasc Intervent Radiol, 1997;8(4) :383

同被引文献21

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部