摘要 目的探讨同源动态能谱CT和MSCT在脊柱扫描中的差异。方法将脊柱疾病患者50例随机分为A、B组两组,每组25例。A组采用同源双电压(80、140kVp)动态扫描,FBP重建单能量图像,记录图像噪声-能级曲线、椎体CNR随能量变化曲线,得出最低图像噪声值及最高CNR值的最佳能级,测量图像噪声及椎体CNR。B组常规MSCT扫描,FBP图像重建。比较两组辐射剂量、图像噪声和椎体CNR。结果 A组最佳能级为70keV,图像噪声为(16.12±1.48)HU,较B组(53.95±4.97)HU明显降低(t=3.25,P<0.05);CNR为5.89±0.46,是B组(1.67±0.15)的3.5倍(t=5.43,P<0.05);容积CT剂量指数为(7.64±0.71)mGy,较B组的(16.34±1.24)mGy降低了53%(t=15.62,P<0.05)。结论同源动态能谱CT脊柱成像较常规MSCT可明显降低辐射剂量,降低图像噪声,提高椎体CNR,改善图像质量。 Objective To explore the differentiations of single source dual-energy(SSDE)CT and MSCT in spine imaging.Methods Fifty patients with spine diseases were randomly divided into A,B groups(each n=25).Group A underwent SSDE(80and 140kVp)CT scans,and monoenergetic images were reconstructed with FBP.The optimal energy level(keV)with lowest image noise and highest contrast to noise ratio(CNR)was determined by recording image noise-energy and vertebral CNR-energy curves,then the image noise and vertebral CNR were measured.Patients in group B underwent conventional MSCT with FBP reconstruction.Radiation dosage,image noise and spine CNR were statistically compared between the two groups.Results In group A,the optimal energy level was at 70 keV,which achieved the highest CNR and lowest noise.Image noise was(16.12±1.48)HU for 70 keV monoenergetic images and(53.95±4.97)HU for conventional CT(t=3.25,P〈0.05).CNR of the vertebral for 70 keV monoenergetic images was 5.89±0.46,which was 3.5times as many as CNR(1.67±0.15)for conventional MSCT(t=5.43,P〈0.05).The CT dose index volume of the dualenergy CT was(7.64±0.71)mGy,which was 53%lower than that of the conventional MSCT([16.34±1.24]mGy,t=15.62,P〈0.05).Conclusion Compared with conventional spine MSCT,SSDE CT can reduce radiation dosage,decrease image noise,increase vertebral CNR and improve image quality.
出处 《中国医学影像技术》 CSCD 北大核心 2015年第4期613-616,共4页 Chinese Journal of Medical Imaging Technology
关键词 脊柱 体层摄影术 X线计算机 图像处理 计算机辅助 辐射剂量 Spine Tomography X-ray computed Image processing computer-assisted Radiation dosage
  • 相关文献

参考文献11

二级参考文献51

  • 1龚静山,徐坚民.Value of multidetector spiral CT in diagnosis of acute thoracolumbar spinal fracture and fracture-dislocation[J].Chinese Journal of Traumatology,2004,7(5):289-293. 被引量:4
  • 2Matsumoto K, Jinzaki M, Tanami Y, et al. Virtual monochromatic spectral imaging with fast kilovohage switching: improved image quality as compared with that obtained with conventional 120 kVp CT. Radiology, 2011 ,In press.
  • 3Lv P, Lin XZ, Li J, et al. Differentiation of small hepatic hemangioma from small hepatocellular carcinoma: recently introduced soectral CT method. Radioloav. 2011. In nress.
  • 4Lin XZ, Miao F, Li JY, et al. High-definition CT gemstone spectral imaging of the brain: initial results of selecting optimal monochromatic image for beam-hardening artifacts and image noise reduction. J Comput Assist Tomogr, 2011, 35:294-297.
  • 5Zhao LQ, He W, Li JY, et al. Improving image quality in portal venography with spectral CT imaging. Eur J Radiol, 2011, In press.
  • 6Feuerlein S, Roessl E, Proksa R, et al. Muhienergy photoncounting K-edge imaging: potential for improved luminal depiction in vascular imaging. Radiology, 2008, 249 : 1010-1016.
  • 7Pan D, Roessl E, Schlomka JP,et al. Computed Tomography in color: nanok-enhanced spectral CT molecular imaging. Angew Chem Int Ed Engl,2010, 49:9635-9639.
  • 8Cormode DP, Roessl E, Thran A, et al. Atherosclerotic plaque composition: analysis with multicolor CT and targeted gold nanoparticles. Radiology, 2010, 256:774-782.
  • 9Shikhalievl PM, Fritz SG. Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application. Phys Med Biol, 2011, 56: 1905-1930.
  • 10Anderson NG, Butler AP, Scott NJA, et al. Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE. Eur Radiol, 2010,20:2126-2134.