期刊文献+

64排螺旋CT血管成像诊断颅内动脉瘤的应用研究 被引量:6

Role of 64 Multi-detector Helical Computer Tomography Angiography in Diagnosis of Intracranial Aneurysm
在线阅读 下载PDF
导出
摘要 目的:探讨64排螺旋CT血管成像(CTA)及后处理技术对颅内动脉瘤诊断的准确性及临床应用价值。方法:对70例行64排螺旋CT血管成像诊断为颅内动脉瘤并进行外科手术治疗的病例进行跟踪随访,影像后处理技术包括多平面重建(MPR)、最大密度投影(MIP)和三维容积再现(VR)。结果:70例患者检出动脉瘤85个,经外科手术证实为动脉瘤76个,9个较小动脉瘤未行手术治疗,3个动脉瘤漏诊。结论:64排螺旋CT血管成像及后处理技术诊断颅内动脉瘤准确性较高,是诊断颅内动脉瘤安全、快速、无创的方法,对临床及时采取治疗具有重要意义。 Object: To investigate the precision and clinical application value of 64 multi-detector helical computer tomography angiography( CTA) and post-processing techniques in diagnosing intracranial aneurysm. Methods: There were totally 70 patients diagnosed as intracranial aneurysm by 64 multi-detector helical CT angiography. All of these patients had surgical resection and were followed up. Post-processing techniques included multiplanar Reconstruction( MPR),maximum intensity projections( MIP) and three dimensional volume rendering( VR). Results: There were 85 intracranial aneurysms in the 70 patients detected by CTA,among them 76 cases were identified by surgery,9 intracranial aneurysms were too small to be operated. Three of these intracranial aneurysms were missed diagnosis. Conclusion: Sixty four multidetector helical CT angiography and post-processing technique has high precision. It is a safe,quick and non-invasive method to diagnose intracranial aneurysm,which is of great significance for timely clinical treatment.
出处 《赣南医学院学报》 2014年第6期906-907,909,共3页 JOURNAL OF GANNAN MEDICAL UNIVERSITY
关键词 颅内动脉瘤 血管成像 64排螺旋CT intracranial aneurysm angiography 64 multi-detector helical computer tomography
  • 相关文献

参考文献5

二级参考文献58

  • 1汪璇,李明华,方淳,潘玉萍,李文彬,乔瑞华.颅颈部动脉狭窄的增强MRA与DSA比较研究[J].介入放射学杂志,2005,14(5):468-471. 被引量:24
  • 2孙继勇,耿跃然,刘怀军.CTA、MRA、DSA诊断颅内动脉瘤的对比研究[J].中国实用神经疾病杂志,2006,9(2):24-25. 被引量:24
  • 3宁殿秀,李智勇,王克礼,苗延巍,伍建林,郎志谨,杜敏安.CT血管成像诊断脑动脉瘤的漏诊原因分析[J].放射学实践,2007,22(4):365-367. 被引量:17
  • 4乐维婕,李明华,李文彬,方淳,李成州.颅颈部血管多层螺旋减影CTA与DSA的比较研究[J].介入放射学杂志,2007,16(5):307-311. 被引量:9
  • 5Salomom E J, Barrett J, Willems PW, et al. Dynamic CT angiogra- phy and CT periusion employing a 320 detector row CI[J]. Kiln Neuroradiol,2009,19(3) : 187-196.
  • 6Page M,Nandurkar I),Crossett MP,el al, Comparison of 4cm Zaxis and 16cm Z-axEs multidetector CT perfuskm[J]. Eur Radiol, 2010,20(6) :1508-1514.
  • 7Siebert E,Bohner G,Dewey M, et al. 320-slice CT neuroimaging: initial clinical experience and image quality evaluation[J]. Br J Ra- diol,2009,82(979) :561-570.
  • 8Klingebiel R,Siebert E,Diekmann S,et al. 4 DImaging in cerebro vascular disorders by using 320-slice CT: feasibility and prelimina- ry clinical experience[J]. Acad Radiol,2009,16(2) :123-129.
  • 9Kangasniemi M, Makela T, Koskinen S, et al. Detection of intracranial aneurysms with two-dimensional and three-dimensional multislice hefical computed torrowaphic angiogaphy. Neurosurgery, 2004, 54: 336-341.
  • 10Tung PP, Olmsted E, Kopelnik A, et al. Plasma B-type natriuretic peptide levels are associated with early cardiac dysfunction atter subarachnoid hemorrhage. Stroke, 2005, 36: 1567-1569.

共引文献54

同被引文献52

引证文献6

二级引证文献26