摘要 Since the research on verification to passive design strategies in sustainable building is at the initial stage,and its test method and verification conclusion are not scientific enough to validate,this paper proposes the necessity of building physical environmental monitoring to quantitative optimization of passive strategies efficiency from the perspective of architecture design and building environment. Adopting comparative research method,this research chooses six types of atrium space in cold climate in China as a prototype,focusing on building physical environmental performance difference in and between atrium and building main space. Spatial parameters of the atrium space will be divided into four factors: spatial geometry,interfacial properties,internal and external related categories. With subdividing these four factors into sub-factors,this paper makes crosscomparison among the sub-factors to clarify passive strategies effectiveness in atrium. Data comparison analysis shows that Winter atrium passive strategy in cold regions from traditional view is not obvious in practical application,and test data need to be stratified refined in atrium design in case of optimizing passive strategy from building prototype perspective. Since the research on verification to passive design strategies in sustainable building is at the initial stage, and its test method and verification conclusion are not scientific enough to validate, this paper proposes the necessity of building physical environmental monitoring to quantitative optimization of passive strategies efficiency from the perspective of architecture design and building environment. Adopting comparative research method, this research chooses six types of atrium space in cold climate in China as a prototype, focusing on building physical environmental performance difference in and between atrium and building main space. Spatial parameters of the atrium space will be divided into four factors : spatial geometry, interfacial properties, internal and external related categories. With subdividing these four factors into sub-factors, this paper makes crosscomparison among the sub-factors to clarify passive strategies effectiveness in atrium. Data comparison analysis shows that Winter atrium passive strategy in cold regions from traditional view is not obvious in practical application, and test data need to be stratified refined in atrium design in case of optimizing passive strategy from building prototype perspective.
出处 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2014年第4期84-90,共7页 哈尔滨工业大学学报(英文版)
基金 Sponsored by the Key Project of National Natural Science Foundation of China (Grant No.51138004) the National Science and Technology Support Program (Grant No.2012BAJ10B02)
关键词 atrium space building physical environment fieldwork test space effect atrium space building physical environment fieldwork test space effect
  • 相关文献

参考文献11

  • 1Rodriguez-Ubinas E, Montero C, Porteros M, et al.Passive design strategies and performance of Net Energy Plus Houses.Energy and Buildings, 4,3: 74-87.
  • 2Morrissey J, Moore T, Horne R E.Affordable passive solar design in a temperate climate: An experiment in residential building orientation.Renewable Energy, 1,6: 568-577.
  • 3Hopfe C J, Augenbroe G L M, Hensen J L M.Multi-criteria decision making under uncertainty in building performance assessment.Building and Environment, 3,9:81-90.
  • 4Kazimieras Z E, Antucheviciene J.Multiple criteria evaluation of rural building's regeneration alternatives.Building and Environment, 7,2: 436-451.
  • 5Tao Lei, Bi Yuan.Research of the atrium space design in ecological buildings.Architecture Journal, 4,8: 20-24.
  • 6Fang Zhenjun, Wu Wenting.Nonecological significance of atrium greening .Journal of Nanjing Forestry University, 6,6: 30-34.
  • 7Liu Xiaobiao.Primary Study on Passive Design of Multi-atrium.Beijing: Tsinghua University, 2011.
  • 8Lei Liang.Pre-research on the Relationship Between Interior Environment Control and Form of Space.Beijing: Tsinghua University, 2005.
  • 9Li Junjie, Song Yehao, Zhao Yuanchao.Study on space layout effect of sustainable public building by field work physical environmental test.Proceedings of the 10th International Conference on Green and Energy-Efficient Building.Beijing.2014.1-11.
  • 10Hummelgaard J, Juhl P, Sabjornsson K O, et al.Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings.Building and Environment, 7,2: 4051-4058.

同被引文献7

引证文献3

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部