摘要
目的 探讨建立注射用头孢唑林钠细菌内毒素定量分析法。方法 采用动态比浊法 ,对注射用头孢唑林钠稀释液进行定量检测。结果 注射用头孢唑林钠在 4mg·ml-1时 ,已无干扰作用。
S:Aim To applied the kinetic turbidimetric technique to detect bacterial endotoxin in Cefazolin Sodium for injection.Methods Kinetic turbidimetric technique.Results The linear range was 0.015 6~1.0EU·ml -1 ,r<-0.98.when the sample was diluted to 4mg·ml -1 ,inhibition and enhancement didn't occur.Conclusion This method can be used to detect the bacterial endotoxin in Cefazolin Sodium for injection.
出处
《解放军药学学报》
CAS
2001年第4期185-186,共2页
Pharmaceutical Journal of Chinese People's Liberation Army
关键词
注射用头孢唑林钠
细菌内毒素
动态比浊法
Cefazolin Sodium for injection
Bacterial Endotoxin
Kinetic Turbidimetric technique