期刊文献+

电感耦合等离子体质谱分析通古斯大爆炸地区沉积物中超痕量铂族元素 被引量:16

Determination of Ultra-trace PGEs in the Sediments Near the Tunguska Explosion Site by ICP-MS
在线阅读 下载PDF
导出
摘要 建立了一个用酸 (HF、HCl、HNO3、HClO4)溶解通古斯地区沉积物样品 ,以Re为内标元素 ,用电感耦合等离子体质谱 (ICP -MS)测定其中铂族元素的分析方法。方法检出限为0 .0 0 1~ 0 .0 6μg/L ,回收率大于 85%。用该方法分析了 9个取自通古斯地区的沉积物样品 ,发现了Ru、Rh、Pd、Ir。 A method for determination of ultra trace platinum group elements (PGEs) in the sediments near the Tunguska explosion site by inductively coupled plasma mass spectrometry (ICP MS) was developed. Samples were decomposed with mixed acids (hydrofluoric acid, aqua regia, nitric acid and perchloric acid). The detection limits for PGEs are 0.001~0.06?μg/L.The recoveries of standard additions are better than 85%. Nine sediment samples taken from Tunguska explosion site were determined by this method. And the anomalies of Ru, Rh, Pd, Ir and Pt were found.
出处 《岩矿测试》 CAS CSCD 北大核心 2001年第2期88-90,共3页 Rock and Mineral Analysis
基金 国家自然科学基金! (4 96 0 2 0 38) 中国科学院岩石圈演化开放实验室课题 !(980 5 9913)
关键词 铂族元素 电感耦合等离子体质谱法 通古斯大爆炸 沉积物 检出限 回收率 platinum group elements (PGEs) inductively coupled plasma mass spectrometry (ICP MS) Tunguska explosion