期刊文献+

一种新型水浴冷冻夹具在大鼠跟腱力学测试中的应用

Application of a New Design of Cryo-jaw and Its Biomechanical Evaluation in Rat Achilles Tendon In Vitro
原文传递
导出
摘要 设计一种新型的冷冻水浴型夹具,用于解决大鼠跟腱力学测试的问题。以SD大鼠肌肉-跟腱-跟骨为单元的样本随机分成A、B两组。A组:大鼠跟腱样本采用设计的新型水浴型冷冻夹具;B组:大鼠跟腱样本采用传统非水浴冷冻夹具。结果显示,在力学测试过程中,A组样本无一滑脱,跟腱处于生理活性状态;B组样本有一根滑脱,其他样本跟腱有明显被冷冻现象。A组样本平均最大应力、最大断裂点位移以及杨氏模量较B组差异均有统计学意义(P<0.05)。实验结果表明,新的冷冻水浴型夹具优于传统非水浴条件冷冻夹具,能够更好地模拟体内环境条件测试跟腱的力学性质。 This study was aimed to design a new, accurate and easy-to-use water bath cryo-jaw, and try to solve the problems met in small animals achilles tendon mechanical testing. The muscle-tendon-bony units were fixed in the clamps. SD rats achilles tendon were randomly divided into group A and B. Group A was tested by the newly de- signed water bath cryo-jaw, while group B was treated by non-water bath cryo-jaw. The mechanical tests revealed that non of the samples of the newly-designed water bath cryo-jaw in group A slipped and fell off, and the achilles tendons were in a physiologically active state, but one of the group B samples slipped and fell off, and the others had the frozen phenomenon obviously. The maximum stress, fracture displacement and Young's modulus of the rats in group A were significantly different compared to those in group B (P〈0.05). In conclusion, the new water bath cryo-jaw has more advantages than traditional ones. It exhibits a good simulation in vivo in the environmental condi- tions for testing the mechanical properties of the achilles tendon.
出处 《生物医学工程学杂志》 EI CAS CSCD 北大核心 2014年第3期678-681,共4页 Journal of Biomedical Engineering
基金 高等学校学科创新引智计划资助项目(国家"111计划")(B06023) 国家自然科学基金资助项目(11032012 31270990) 新世纪优秀人才支持计划资助项目(NCET-10-0879) 重庆大学大型仪器设备开放基金资助项目
关键词 冷冻水浴型夹具 跟腱 力学拉伸测试 应用 frozen water bath Cryo-jaw achilles tendon mechanical stretch test application
  • 相关文献

参考文献10

  • 1CARPENTER J E, HANKENSON K D. Animal models of tendon and ligament injuries for tissue engineering applica- tions[J]. Biomaterials, 2004, 25(9): 1715-1722.
  • 2CARPENTER J E, THOMOPOULOS S, SOSLOWSKY L J. Animal models of tendon and ligament injuries for tissue engineering applications [J]. Clin Orthop Relat Res, 1999, 367(Suppl) : S296-S311.
  • 3CHEN X, SONG X H, YIN Z, et al. Stepwise differentiation of human embryonic stem cells promotes tendon regeneration by secreting fetal tendon matrix and differentiation factors [J]. Stem Cells, 2009, 27(6): 1276-1287.
  • 4SHEN W, CHEN X, CHEN J, et al. The effect of incorpo- ration of exogenous stromal cell-derived factor-1 alpha within a knitted silk-collagen sponge scaffold on tendon regeneration [J]. Biomaterials, 2010, 31(28): 7239-7249.
  • 5HALDER A, ZOBITZ M E, SCHULTZ F, et al. Mechanical properties of the posterior rotator cuff [J]. Clin Biomech (Bristol, Avon), 2000, 15(6): 456-462.
  • 6SODEN P D, KERSHAW I. Tensile testing of connective tis- sues[J]. Med Biol Eng, 1974, 12(4) :510-518.
  • 7MATTHEWS G I., KEEGAN K G, GRAHAM H L. Effects of tendon grip technique (frozen versus unfrozen) on in vitro surface strain measurements of the equine deep digital flexor tendon[J]. AmJ Vet Res, 1996, 57(1) :111-115.
  • 8RIEMERSA D J, SCHAMHARDT H C. The cryo-jaw, a clamp designed for in vitro rheology studies of horse digital flexor tendons[J]. J Biomech, 1982, 15(8): 619-620.
  • 9WIELOCH P, BUCHMANN G, ROTH W, et al. A eryo- jaw designed for in vitro tensile testing of the healing achilles tendons in rats [J]. J Biomech, 2004, 37(11) : 1719-1722.
  • 10SHARKEY N A, SMITH T S, LUNDMARK D C. Freeze clamping museulo-tendinous junctions for in vitro simulation of joint mechanics[J]. J Biomech, 1995, 28(5) : 631-635.